Study on Corrosion of Reinforced Concrete with Synthetic Fiber Using Electrochemical Noise Technique

被引:0
作者
Flores-Nicolas, Alejandro [1 ]
Flores-Nicolas, Mario [2 ]
Menchaca-Campos, Elsa C. [1 ]
Uruchurtu-Chavarin, Jorge [1 ]
机构
[1] Univ Autonoma Estado Morelos, Ctr Invest Ingn & Ciencias Aplicadas, Cuernavaca, Mexico
[2] Univ Nacl Autonoma Mexico, Inst Ingn, Mexico City, Mexico
关键词
Corrosion; Synthetic fibers; Reinforced concrete; Electrochemical noise; POLARIZATION; STEEL;
D O I
10.2478/cee-2025-0021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this work, the objective of this study is the incorporation of synthetic fibers in the elaboration of concrete to improve the corrosion resistance of embedded steel. Cubic concrete test pieces were manufactured and long fibers of 3 cm dimensions, 0.3-0.4 cm wide and 0.05 cm thick were used, in quantities of 0.2% and 0.4% in partial substitution of fine aggregate. The specimens were immersed for 168 days in a saline environment at 3% NaCl. The electrochemical noise technique was applied to monitor the corrosion resistance, studying the time series phenomena on the potential and the current. Statistical values of the electrochemical noise resistance parameters and the localization index were analysed to identify the corrosion model present in the system. It was shown that the use of synthetic fibers in higher volume increased the corrosion process of the steel at specific areas of the metal surface presenting localized corrosion.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Evaluation of reinforcement corrosion rate in concrete structures by electrochemical noise measurements
    Smulko, J. M.
    Darowicki, K.
    Zielinski, A.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2006, 42 (05) : 546 - 550
  • [32] Electrochemical polarization and impedance of reinforced concrete and hybrid fiber-reinforced concrete under cracked matrix conditions
    Nguyen, Wilson
    Duncan, Jacob F.
    Devine, Thomas M.
    Ostertag, Claudia P.
    ELECTROCHIMICA ACTA, 2018, 271 : 319 - 336
  • [33] Evaluation of reinforcement corrosion rate in concrete structures by electrochemical noise measurements
    J. M. Smulko
    K. Darowicki
    A. Zieliński
    Russian Journal of Electrochemistry, 2006, 42 : 546 - 550
  • [34] Shear Strength of Synthetic Fiber-Reinforced Concrete Box Culverts
    Mostafazadeh, Mahnaz
    Abolmaali, Ali
    Ghahremannejad, Masoud
    JOURNAL OF BRIDGE ENGINEERING, 2019, 24 (06)
  • [35] Electrochemical techniques for corrosion assessment of reinforced concrete structures
    Gowers, KR
    Millard, SG
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1999, 134 (02) : 129 - 137
  • [36] Effect of Cathodic Protection on Reinforced Concrete with Fly Ash Using Electrochemical Noise
    Garcia-Contreras, Jorge
    Gaona-Tiburcio, Citlalli
    Lopez-Cazares, Irene
    Sanchez-Diaz, Guillermo
    Ibarra Castillo, Juan Carlos
    Jaquez-Munoz, Jesus
    Nieves-Mendoza, Demetrio
    Maldonado-Bandala, Erick
    Olguin-Coca, Javier
    Lopez-Leon, Luis Daimir
    Almeraya-Calderon, Facundo
    MATERIALS, 2021, 14 (09)
  • [37] Development of technique capable of identifying different corrosion stages in reinforced concrete
    Qin, Lei
    Ren, Hongwei
    Dong, Biqin
    Xing, Feng
    APPLIED ACOUSTICS, 2015, 94 : 53 - 56
  • [38] Analytical study on shear strength of macro synthetic fiber reinforced concrete beams
    Yazdanbakhsh, Ardavan
    Altoubat, Salah
    Rieder, Klaus-Alexander
    ENGINEERING STRUCTURES, 2015, 100 : 622 - 632
  • [39] Stress Corrosion Cracking Study of Aluminum Alloys Using Electrochemical Noise Analysis
    Rathod, R. C.
    Sapate, S. G.
    Raman, R.
    Rathod, W. S.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2013, 22 (12) : 3801 - 3809
  • [40] Corrosion process and abatement in reinforced concrete wrapped by fiber reinforced polymer
    Spainhour, Lisa K.
    Wootton, Isaac A.
    CEMENT & CONCRETE COMPOSITES, 2008, 30 (06) : 535 - 543