Dual-functional monomers in molecularly imprinted polymer synthesis for electrochemical detection of bisacodyl in biological samples based on lab-made screen-printed carbon electrode

被引:0
|
作者
Nezhadali, Azizollah [1 ]
Badameh, Anousheh [1 ]
机构
[1] Payame Noor Univ, Dept Chem, POB 193954697, Tehran 19569, Iran
关键词
Dual-functional monomers; Molecularly imprinted polymer; Screen-printed carbon electrode; Bisacodyl; Graphene oxide; Voltammetry; SPECTROPHOTOMETRIC DETERMINATION; SENSOR; NANOTUBES; LAXATIVES; PYRROLE; URINE; FILM;
D O I
10.1007/s10008-025-06303-3
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, the utilization of two monomers, specifically pyrrole (PY) and thiophene (TH), was investigated for the synthesis of dual-monomer molecularly imprinted polymer (DMMIP) used in the electrochemical detection of bisacodyl (BIS) in biological samples. To examine the impact of each monomer individually and in combination on the formation of DMMIP, a density functional theory (DFT) approach was utilized. This calculation was employed to enhance the selectivity of the MIP towards the target molecule BIS. The DMMIP was electropolymerized using cyclic voltammetry (CV) of monomers and template on a lab-made screen-printed carbon electrode (SPCE) that had been modified with graphene oxide (GO). Differential pulse voltammetry (DPV) was then utilized for the accurate determination of BIS levels. The influencing factors in the DMMIP synthesis, such as the PY to BIS ratio, the TH to BIS ratio, pH, scan rate, and the number of scans, were optimized using a Taguchi array. In addition, other parameters such as the stirring rate, loading time, and the amount of GO were analyzed using the one-factor-at-a-time (OFAT) approach. Under optimized conditions, the sensor demonstrated a linear dynamic range from 0.1 to 1000 mu M (R2 = 0.9984) with limits of detection and quantification of 0.063 mu M (S/N = 3) and 0.21 mu M (S/N = 10), respectively. The sensor also exhibited good repeatability and reproducibility, with relative standard deviations (RSD) of 1.4% and 2.7%, respectively. Moreover, this sensor successfully detected BIS in real samples and showed a good agreement with high-performance liquid chromatography (HPLC) results.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Electrochemical determination of 5-heneicosylresorcinol using a disposable molecularly imprinted polymer-modified screen-printed electrode
    Wang, Mengyao
    Gong, Weiwei
    Yu, Zhenjia
    Wang, Hailin
    Sun, Ruiqing
    Wen, Yangyang
    Li, Hongyan
    Wang, Jing
    FOOD CONTROL, 2025, 171
  • [22] Disposable Electrochemical Ascorbic Acid Sensor Based on Molecularly Imprinted Poly(o-phenylenediamine)-Modified Dual Channel Screen-Printed Electrode for Orange Juice Analysis
    Zhao, Xiaojuan
    Zhang, Wei
    Chen, Haiguang
    Chen, Yuejiao
    Huang, Guiying
    FOOD ANALYTICAL METHODS, 2014, 7 (07) : 1557 - 1563
  • [23] Electrochemical Detection of Celestine Blue Based on Screen Printed Carbon Electrode Modified with Molecular Imprinted Polymer and NiO Nanoparticles
    Roushani, Mahmoud
    Saedi, Zahra
    Karazan, Zahra Mirzaei
    Azadbakht, Azadeh
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2021, 8 (04): : 493 - 504
  • [24] A Non-Enzymatic Electrochemical Uric Acid Sensor Based on a Screen-Printed Electrode Modified with a Photopolymerized Molecularly Imprinted Polymer Membrane
    Ulianas, Alizar
    Hanifah, Sharina Abu
    Abdullah, Jaafar
    Aini, Syamsi
    Kurniawati, Desy
    Hassan, Riyadh Abdulmalek
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (03)
  • [25] Electrochemical Determination of Human Growth Hormone (HGH) Utilizing A Pyrrole (Py) Molecularly Imprinted Polymer (MIP) On Screen-Printed Carbon Electrode (SPCE)
    Bohlooli, Shahriar
    Kia, Solmaz
    Bohlooli, Shahab
    Sariri, Reyhaneh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (05): : 410 - 427
  • [26] Synthesis and characterization of a highly sensitive and selective electrochemical sensor based on molecularly imprinted polymer with gold nanoparticles modified screen-printed electrode for glycerol determination in wastewater
    Motia, Soukaina
    Bouchikhi, Benachir
    Llobet, Eduard
    El Bari, Nezha
    TALANTA, 2020, 216
  • [27] Cytochrome c electrochemical detection utilizing molecularly imprinted poly(3, 4-ethylenedioxythiophene) on a disposable screen printed carbon electrode
    Kaniraja, Ganesan
    Karthikeyan, Murugesan
    Kumar, Marimuthu Dhinesh
    Ananthappan, Periyasamy
    Kumar, Karuppiah Arunsunai
    Shanmugaiah, Vellasamy
    Vasantha, Vairathevar Sivasamy
    Karunakaran, Chandran
    ANALYTICAL BIOCHEMISTRY, 2024, 692
  • [28] Electrochemical quercetin sensor based on a nanocomposite consisting of magnetized reduced graphene oxide, silver nanoparticles and a molecularly imprinted polymer on a screen-printed electrode
    Yao, Zufu
    Yang, Xin
    Liu, Xiaobo
    Yang, Yaqi
    Hu, Yangjian
    Zhao, Zijian
    MICROCHIMICA ACTA, 2018, 185 (01)
  • [29] Screen-printed carbon electrode-based electrochemical immunosensor for rapid detection of microalbuminuria
    Tsai, Jang-Zern
    Chen, Ching-Jung
    Settu, Kalpana
    Lin, Yu-Feng
    Chen, Chien-Lung
    Liu, Jen-Tsai
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 1175 - 1182
  • [30] Disposable Electrochemical Ascorbic Acid Sensor Based on Molecularly Imprinted Poly(o-phenylenediamine)-Modified Dual Channel Screen-Printed Electrode for Orange Juice Analysis
    Xiaojuan Zhao
    Wei Zhang
    Haiguang Chen
    Yuejiao Chen
    Guiying Huang
    Food Analytical Methods, 2014, 7 : 1557 - 1563