Potential length of stay reductions from emergency department use of a point-of-care high-sensitivity cardiac troponin assay: Pilot findings from Australia's first cardiac emergency department

被引:0
作者
Meek, Robert [1 ,2 ]
Hayden, Georgina [1 ,2 ]
Lu, Zhong X. [2 ,3 ]
Damianopoulos, Adam [1 ]
Cullen, Louise [4 ,5 ]
Kumarakurusingham, Evan [1 ]
Pathirana, Pavith [1 ,6 ]
Than, Martin [7 ,8 ,9 ]
Pickering, John W. [7 ,8 ]
Doery, James [2 ,3 ]
Duong, Alex [1 ,2 ]
Egerton-Warburton, Diana [1 ,2 ]
机构
[1] Monash Hlth, Victorian Heart Hosp, Melbourne, Vic, Australia
[2] Monash Univ, Dept Med, Melbourne, Vic, Australia
[3] Monash Hlth, Monash Hlth Pathol, Melbourne, Vic, Australia
[4] Royal Brisbane & Womens Hosp, Emergency & Trauma Ctr, Brisbane, Qld, Australia
[5] Univ Queensland, Fac Med, Brisbane, Qld, Australia
[6] Monash Univ, Monash Hlth, Sch Clin Sci, Melbourne, Vic, Australia
[7] Christchurch Hosp, Dept Emergency Med, Christchurch, New Zealand
[8] Univ Otago Christchurch, Dept Med, Christchurch, New Zealand
[9] Kansas Univ, Med Ctr, Dept Emergency Med, Kansas City, KS USA
关键词
diagnosis; emergency department; length of stay; myocardial infarction; point-of-care;
D O I
10.1111/1742-6723.70041
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
ObjectiveTo compare actual ED length of stay (LOS) using laboratory-based high-sensitivity cardiac troponin I (hs-cTnI) testing with the potential LOS that could result from using point-of-care (POC) hs-cTnI tests.MethodsBaseline hs-cTnI tests were performed on the same blood sample in the laboratory (Access hsTnI assay) and in the ED (Atellica VTLi POC assay). Actual and potential LOS were compared for patients who were discharged after having a baseline laboratory hs-cTnI test only. Total LOS incorporated time from arrival to blood sample collection, blood sampling to result availability and result availability to discharge. For potential LOS, the blood sampling to result availability time with POC use was fixed at 10 min (2-min preparation and 8-min test-processing). The laboratory blood sampling to result availability time was from blood sample collection to result uploading on the pathology computer system. For the study, it was assumed that this was the only LOS component that would differ with POC use. Invalid POC result rates were monitored.ResultsFor 152 patients discharged after having a single baseline laboratory hs-cTnI test, the median actual LOS was 195 (interquartile range [IQR]: 152-319) min, which included a median laboratory blood-sampling-to-result-availability time of 48 (IQR: 41-59) min. The potential LOS from POC use was 157 (IQR: 103-282) min, which included the fixed 10-min blood-sampling-to-result-availability time. The mean actual-potential LOS difference was 43 (95% confidence interval [CI]: 40-46) min. The POC invalid result rate was 11%.ConclusionThe Atellica VTLi could deliver a mean ED LOS reduction of 43-min per patient for those discharged after a single baseline hs-cTnI test. Use in actual practice and the invalid result rate require further evaluation.
引用
收藏
页数:8
相关论文
共 30 条
  • [1] Global Adoption of High-Sensitivity Cardiac Troponins and the Universal Definition of Myocardial Infarction
    Anand, Atul
    Shah, Anoop S., V
    Beshiri, Agim
    Jaffe, Allan S.
    Mills, Nicholas L.
    [J]. CLINICAL CHEMISTRY, 2019, 65 (03) : 484 - 489
  • [2] Determination of sex-specific 99th percentile upper reference limits for a point of care high sensitivity cardiac troponin I assay
    Apple, Fred S.
    Schulz, Karen
    Schmidt, Christian W.
    van Domburg, Trees S. Y.
    Fonville, Judith M.
    de Theije, Femke K.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (09) : 1574 - 1578
  • [3] Single High-Sensitivity Point-of-Care Whole-Blood Cardiac Troponin I Measurement to Rule Out Acute Myocardial Infarction at Low Risk
    Apple, Fred S.
    Smith, Stephen W.
    Greenslade, Jaimi H.
    Sandoval, Yader
    Parsonage, William
    Ranasinghe, Isuru
    Gaikwad, Niranjan
    Schulz, Karen
    Stephensen, Laura
    Schmidt, Christian W.
    Okeson, Brynn
    Cullen, Louise
    [J]. CIRCULATION, 2022, 146 (25) : 1918 - 1929
  • [4] Australasian College for Emergency Medicine, 2024, Emergency Department Short Stay Units: Guidelines (G554). V2
  • [5] Australian Institute of Health and Welfare, 2023, Emergency Department Care Activity
  • [6] High-sensitivity assay for cardiac troponins with POCT methods. The future is soon
    Clerico, Aldo
    Zaninotto, Martina
    Plebani, Mario
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (09) : 1477 - 1478
  • [7] Australia's first cardiac emergency department: Patient profile, activity and performance in the initial 6 months
    Cohen, Adam C.
    Meek, Robert
    Hayden, Georgina
    Damianopoulos, Adam
    Goldie, Neil
    Lim, Joel J. Y.
    Duong, Alex
    Egerton-Warburton, Diana
    [J]. EMERGENCY MEDICINE AUSTRALASIA, 2024, 36 (06) : 876 - 883
  • [8] Management of acute coronary syndromes in patients presenting without persistent ST-segment elevation and coexistent atrial fibrillation - Dual versus triple antithrombotic therapy
    Collet, Jean-Philippe
    Thiele, Holger
    [J]. EUROPEAN HEART JOURNAL, 2021, 42 (20) : 2020 - 2021
  • [9] High sensitivity, contemporary and point-of-care cardiac troponin assays: educational aids developed by the IFCC Committee on Clinical Application of Cardiac Bio-Markers
    Collinson, Paul O.
    Saenger, Amy K.
    Apple, Fred S.
    Chair, Fred S. Apple
    Body, Richard
    Kaysak, Pete A.
    Lam, Carolyn S. P.
    Lefevre, Guillaume
    Pulkki, Kari
    Omland, Torbjorn
    Jaffe, Allan S.
    Ordonez-Llanos, Jordi
    Ravalico, Abbott-Tricia
    San George, Rick
    Sun, Lindsay Xuan
    Leclair, Margot
    Zuk, Robert
    Tan, Hong
    Walton, Kaye
    Maertens, Rikkert
    Ocklenburg, F.
    Takeshi, Matsuya
    DiMagno, Lisa
    Patru, Maria
    Ohm, Jakob
    Trupp, Robin
    Albert, Gesa
    Jennings, Sherry
    Ortisi, Alessandro
    Wilson, Kimberly
    Olson, Kalen
    Sandland, Johanna
    Todd, John
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (05) : 623 - 632
  • [10] Point-of-care high-sensitivity cardiac troponin in suspected acute myocardial infarction assessed at baseline and 2 h
    Cullen, Louise
    Greenslade, Jaimi
    Parsonage, William
    Stephensen, Laura
    Smith, Stephen W.
    Sandoval, Yader
    Ranasinghe, Isuru
    Gaikwad, Niranjan
    Bayat, Maryam Khorramshahi
    Mahmoodi, Ehsan
    Schulz, Karen
    Than, Martin
    Apple, Fred S.
    [J]. EUROPEAN HEART JOURNAL, 2024, 45 (28) : 2508 - 2515