How Much Does a Computed Tomography-Based Mixed-Reality Navigation System Change Freehand Acetabular Component Position?

被引:1
作者
Leal, Justin [1 ]
Heimann, Alexander F. [2 ]
Dilbone, Eric S. [1 ]
Ryan, Sean P. [1 ]
Wellman, Samuel S. [1 ]
机构
[1] Duke Univ, Dept Orthopaed Surg, Durham, NC USA
[2] Univ Fribourg, HFR Fribourg & Cantonal Hosp, Dept Orthopaed Surg & Traumatol, Fribourg, Switzerland
关键词
Total hip arthroplasty (THA); Augmented-reality (AR); Mixed-reality (MR); Inclination; Anteversion; TOTAL HIP-ARTHROPLASTY; SAFE ZONE; CUP PLACEMENT; POLYETHYLENE WEAR; ACCURACY; DISLOCATION; RISK; THA; ORIENTATION; INSTABILITY;
D O I
10.1016/j.artd.2025.101661
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study evaluates how a computed tomography-based mixed-reality (MR) navigation system impacts acetabular component orientation compared to freehand positioning in total hip arthroplasty. Methods: A series of 79 patients who underwent total hip arthroplasty utilizing a computed tomography-based MR navigation system were reviewed. The surgeon initially placed the acetabular cup freehand, attempting to achieve the preoperative plan, and this initial intraoperative orientation was recorded. The cup was then adjusted to the planned position. The difference between freehand and planned tilt-adjusted operative anteversion (OA) and inclination (OI) determined the navigation tool's impact. Results: The mean preoperative planned OA was 30.1 +/- 2.0 (range: 25, 35) degrees, and the mean freehand intraoperative OA was 30.2 +/- 9.1 (range: 4, 57) degrees (P 1/4 .885), requiring a mean adjustment of 6.8 +/- 5.1 (range: 0,23) degrees. Freehand OA was corrected at least 5 degrees in 54.4% (43/79) of cases. The mean preoperative planned OI was 40.8 +/- 0.6 (range: 39, 42) degrees, and the mean freehand intraoperative OI was 37.8 +/- 6.6 (range: 18, 53) degrees (P < .001), requiring a mean adjustment of 5.7 +/- 4.5 (range: 0, 22) degrees to achieve. Freehand OI was corrected at least 5 degrees in 43.0% (34/79) of cases. Conclusions: Freehand acetabular component positioning in the lateral position is variable when attempting to execute patient-specific numerical cup orientation targets. Use of this navigation tool led the surgeon to correct more than 5 degrees in both OA and OIin roughly half of the hips. (c) 2025 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:9
相关论文
共 57 条
[41]   Polyethylene wear and acetabular component orientation [J].
Patil, S ;
Bergula, A ;
Chen, PC ;
Colwell, CW ;
D'Lima, DD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :56-63
[42]   Patient-Specific Safe Zones for Acetabular Component Positioning in Total Hip Arthroplasty: Mathematically Accounting for Spinopelvic Biomechanics [J].
Ramkumar, Primary Hip Prem N. ;
Pang, Michael ;
Vigdorchik, Jonathan M. ;
Chen, Antonia F. ;
Iorio, Richard ;
Lange, Jeffrey K. .
JOURNAL OF ARTHROPLASTY, 2023, 38 (09) :1779-1786
[43]   Can a target zone safer than Lewinnek's safe zone be defined to prevent instability of total hip arthroplasties? Case-control study of 56 dislocated THA and 93 matched controls [J].
Reina, N. ;
Putman, S. ;
Desmarehelier, R. ;
Ali, E. Sari ;
Chiron, P. ;
Ollivier, M. ;
Jenny, J. Y. ;
Waast, D. ;
Mabit, C. ;
de Thomasson, E. ;
Schwartz, C. ;
Oger, P. ;
Gayet, L. E. ;
Migaud, H. ;
Ramdane, N. ;
Fessy, M. H. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (05) :657-661
[44]   Enhanced Total Hip Arthroplasty Education Using Augmented Reality: A Survey From a Tertiary Center [J].
Ryan, Sean P. ;
Cochrane, Niall ;
Bolognesi, Michael P. ;
Wellman, Samuel S. .
ORTHOPEDICS, 2024, 47 (04) :157-160
[45]   Acetabular Component Position and the Risk of Dislocation Following Primary and Revision Total Hip Arthroplasty: A Matched Cohort Analysis [J].
Sadhu, Anita ;
Nam, Denis ;
Coobs, Benjamin R. ;
Barrack, Toby N. ;
Nunley, Ryan M. ;
Barrack, Robert L. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (03) :987-991
[46]   Comparison of Three-Dimensional Planning-Assisted and Conventional Acetabular Cup Positioning in Total Hip Arthroplasty A Randomized Controlled Trial [J].
Sariali, Elhadi ;
Boukhelifa, Nadia ;
Catonne, Yves ;
Moussellard, Hugues Pascal .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (02) :108-116
[47]   Accurate femur repositioning is critical during intraoperative total hip arthroplasty length and offset assessment [J].
Sarin, VK ;
Pratt, WR ;
Bradley, GW .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :887-891
[48]   The Hip-Spine Relationship in Total Hip Arthroplasty: How to Execute the Plan [J].
Sharma, Abhinav K. ;
Vigdorchik, Jonathan M. .
JOURNAL OF ARTHROPLASTY, 2021, 36 (07) :S111-S120
[49]   Robotics Versus Navigation Versus Conventional Total Hip Arthroplasty: Does the Use of Technology Yield Superior Outcomes? [J].
Singh, Vivek ;
Realyvasquez, John ;
Simcox, Trevor ;
Rozell, Joshua C. ;
Schwarzkopf, Ran ;
Davidovitch, Roy, I .
JOURNAL OF ARTHROPLASTY, 2021, 36 (08) :2801-2807
[50]   Improving Cup Positioning Using a Mechanical Navigation Instrument [J].
Steppacher, Simon D. ;
Kowal, Jens H. ;
Murphy, Stephen Barry .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :423-428