Dynamic cooling: Thermal and temporal effects on cognitive load and performance in office environments

被引:0
|
作者
Reitmayer, Amelie [1 ]
Koth, Sebastian Clark [2 ]
Johnstone, Kelly R. [1 ]
Madigan, Cassandra [1 ]
Cook, Margaret M. [1 ]
机构
[1] Univ Queensland, Sch Environm, St Lucia, Qld 4072, Australia
[2] Tech Univ Munich, Chair Bldg Technol & Climate Respons Design, TUM Sch Engn & Design, Arcisstr 21, D-80333 Munich, Germany
关键词
Thermal environment; Cognitive performance; Dynamic cooling; Temporal effects; Thermal comfort; Office workplace; VISUOSPATIAL WORKING-MEMORY; CIRCADIAN-RHYTHMS; COMFORT; TEMPERATURE; PSYTOOLKIT; PACKAGE; TESTS; MODEL; TIME;
D O I
10.1016/j.buildenv.2025.112986
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The integration of dynamic thermal environments, characterised by time-varying temperatures within a building, can contribute to increased energy flexibility and a reduction in overall energy consumption. Recent research indicates that exposure to varying temperatures has the potential to enhance worker performance and wellbeing. This study examined the time-dependent impacts of temperature exposure on cognitive load and performance. In a simulated real-world office environment, 36 participants were exposed to automated conditions, including a conventional constant temperature cooled (CC) condition of 23 degrees C and a dynamic cooled (DC) condition with a constant temperature of 26 degrees C in the morning and a temperature change of 1.5 degrees C/h after lunch, resulting in a temperature of 23 degrees C in the afternoon. In both conditions, performance tasks, mental workload, arousal and thermal perception questionnaires were conducted at hourly intervals throughout the working day, from 9:00 am to 4:00 pm. Results showed similar performance in both conditions with no direct relation to a set-point temperature. The analysis of the time of day revealed significant effects in both conditions. In the morning, participants rated feeling significantly more relaxed and thermally comfortable in the higher temperature in DC than in the lower temperature in CC. During the afternoon, an increase in self-reported fatigue was observed in the CC condition, which could be significantly mitigated by the dynamic condition. The findings of the study challenge the practice of maintaining constant temperatures in offices, underscoring the need to consider the impact of time of day variations on workers' wellbeing.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Effects of non-Newtonian behaviour on the thermal performance of nanofluids in a horizontal channel with discrete regions of heating and cooling
    Li, Botong
    Lin, Yanhai
    Zhu, Liangliang
    Zhang, Wei
    APPLIED THERMAL ENGINEERING, 2016, 94 : 404 - 412
  • [42] Effects of Temporal Light Modulation on Cognitive Performance,Eye Movements, and Brain Function
    Veitch J.A.
    Van Roon P.
    D’Angiulli A.
    Wilkins A.
    Lehman B.
    Burns G.J.
    Dikel E.E.
    LEUKOS - Journal of Illuminating Engineering Society of North America, 2024, 20 (01): : 67 - 106
  • [43] Analytical expression of dynamic cooling load of non-uniform environment considering the thermal mass of convective boundaries
    Yan, Shuai
    Li, Xianting
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [44] Thermal effects on human performance in office environment measured by integrating task speed and accuracy
    Lan, Li
    Wargocki, Pawel
    Lian, Zhiwei
    APPLIED ERGONOMICS, 2014, 45 (03) : 490 - 495
  • [45] Design and thermal performance assessment of water sink based thermoelectric radiant panel system for office cabinet cooling and heating
    Mishra, Gaurav
    Prajapati, Satyendra
    Prajapat, Mayankraj
    Mathur, Jyotirmay
    Prabhakar, Aneesh
    APPLIED THERMAL ENGINEERING, 2025, 262
  • [46] Productivity in office with elevated preset temperature in summer - Improvement of thermal satisfaction by cooling methods and its effect on performance and fatigue
    Haned, Masaoki
    Nishihara, Naoe
    Kawaguchi, Gen
    Tanabe, Skin-Icht
    Journal of Environmental Engineering, 2009, 74 (646) : 1329 - 1337
  • [47] The Effects of Cooling Structure and Li-ion Battery Specification on the Cooling Performance of a Passive Thermal Management System
    Zhao, Rui
    Liu, Jie
    Gu, Junjie
    2017 INTERNATIONAL CONFERENCE ON SENSING, DIAGNOSTICS, PROGNOSTICS, AND CONTROL (SDPC), 2017, : 662 - 669
  • [48] Comprehensive analysis on thermal and daylighting performance of glazing and shading designs on office building envelope in cooling-dominant climates
    Huang, Yu
    Niu, Jian-lei
    Chung, Tse-ming
    APPLIED ENERGY, 2014, 134 : 215 - 228
  • [49] A Comparative Study of Colour Effects on Cognitive Performance in Real-World and VR Environments
    Xia, Guobin
    Henry, Philip
    Li, Muzi
    Queiroz, Francisco
    Westland, Stephen
    Yu, Luwen
    BRAIN SCIENCES, 2022, 12 (01)
  • [50] Study on dynamic thermal performance and optimization of hybrid systems with capillary mat cooling and displacement ventilation
    Li, Nan
    Chen, Qiong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 110 : 196 - 207