An integrated physical model and extant data based approach for fault diagnosis and failure prognosis: Application to a photovoltaic module

被引:0
|
作者
Mebarki, Nassima [1 ]
Mouss, Leila-Hayet [1 ]
Bentrcia, Toufik [1 ]
Benmoussa, Samir [2 ]
机构
[1] Univ Batna 2, Lab Automation & Mfg Engn, Batna 05000, Algeria
[2] Badji Mokhtar Annaba Univ, Lab Automat & Signaux Annaba LASA, Annaba 23000, Algeria
关键词
Remaining useful lifetime; Fault detection; Gaussian mixture model; Similarity; Bond graph; Photovoltaic module; DATA-DRIVEN; BOND GRAPH; DEGRADATION; PREDICTION; FRAMEWORK; SYSTEMS; CELLS;
D O I
10.1016/j.microrel.2025.115711
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nowadays, the increasing tendency towards the exploitation of solar energy has yielded many technological advancements. Hybrid approaches are attracting attention worldwide to ensure the comprehensive assessment of photovoltaic modules reliability becoming a crucial issue. The present study is dedicated to the investigation of an innovative approach integrating Bond graph theory, Gaussian mixture models and Similarity-based method for fault detection and remaining useful life prediction. In this context, Bond graphs are exploited first to create a dataset covering diverse operational modes of the system. The identification and evaluation of critical sensors for fault observability is also considered, where the dataset is optimized based on the variance analysis. The Gaussian mixture model with its semi-supervised initialization is then utilized for clustering and fault diagnosis, while remaining useful life estimation is performed using a pairwise similarity technique. Validation results on a photovoltaic panel model demonstrate that the Gaussian mixture model consistently outperforms the classical k-Nearest Neighbors model across all key metrics (accuracy of 0.9396 vs. 0.7577, precision of 0.9192 vs. 0.5570, recall of 0.7849 vs. 0.5628, and F1-score of 0.8666 vs. 0.6707), highlighting its superior performance. The remaining useful lifetime model also achieves high accuracy, with Root Mean Square Error values ranging from 0.0282 to 0.0300, indicating minimal prediction error. Additionally, the R-Squared value of similar to 0.92 shows that the model explains approximately 92% of the variance in remaining useful lifetime predictions, underscoring its strong predictive capability. The results demonstrate the practical effectiveness of the proposed framework for both single and multiple faults. However, some limitations are noted, such as the exclusion of the transition phase in training data and the reliance on controlled conditions. The outcomes of this work are expected to provide valuable insights into the implementation of efficient hybrid frameworks, contributing to the sustainable development of solar energy.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Photovoltaic Module Current Mismatch Fault Diagnosis Based on I-V Data
    Ma, Mingyao
    Zhang, Zhixiang
    Yun, Ping
    Xie, Zhen
    Wang, Haisong
    Ma, Wenting
    IEEE JOURNAL OF PHOTOVOLTAICS, 2021, 11 (03): : 779 - 788
  • [2] Experimental Application on a Mechanical Transmission System of Integrated Fault Diagnosis and Fault Prognosis method
    Benmoussa, S.
    Djeziri, M. A.
    IFAC PAPERSONLINE, 2018, 51 (24): : 1016 - 1023
  • [3] Fault diagnosis and prognosis based on physical knowledge and reliability data: Application to MOS Field-Effect Transistor
    Djeziri, M. A.
    Benmoussa, S.
    Mouchaweh, M. Sayed
    Lughofer, E.
    MICROELECTRONICS RELIABILITY, 2020, 110
  • [4] An integrated architecture for fault diagnosis and failure prognosis of complex engineering systems
    Chen, Chaochao
    Brown, Douglas
    Sconyers, Chris
    Zhang, Bin
    Vachtsevanos, George
    Orchard, Marcos E.
    EXPERT SYSTEMS WITH APPLICATIONS, 2012, 39 (10) : 9031 - 9040
  • [5] Fault diagnosis of crystalline silicon photovoltaic module based on I-V characteristic analysis
    Ma M.
    Zhang Z.
    Liu H.
    Yun P.
    Liu F.
    Zhang X.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (06): : 130 - 137
  • [6] The Integrated-Servo-Actuator Degradation Prognosis Based on the Physical Model Combined With Data-Driven Approach
    Cui, Zhanbo
    Jing, Bo
    Jiao, Xiaoxuan
    Huang, Yifeng
    Wang, Shenglong
    IEEE SENSORS JOURNAL, 2023, 23 (09) : 9370 - 9381
  • [7] A Data Analytic Approach to Automatic Fault Diagnosis and Prognosis for Distribution Automation
    Wang, Xiaoyu
    McArthur, Stephen D. J.
    Strachan, Scott M.
    Kirkwood, John D.
    Paisley, Bruce
    IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (06) : 6265 - 6273
  • [8] A particle-filtering approach for on-line fault diagnosis and failure prognosis
    Orchard, Marcos E.
    Vachtsevanos, George J.
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2009, 31 (3-4) : 221 - 246
  • [9] Application of model-based and data-driven techniques in fault diagnosis
    Wang Ziling
    Xu Aiqiang
    Yang Zhiyong
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL III, 2007, : 451 - +
  • [10] FAULT DETECTION AND DIAGNOSIS OF PHOTOVOLTAIC SYSTEM BASED ON NEURAL NETWORKS APPROACH
    Ben Rahmoune M.
    Iratni A.
    Amari A.S.
    Hafaifa A.
    Colak I.
    Diagnostyka, 2023, 24 (03):