Reference values for arm ergometry cardiopulmonary exercise testing (CPET) in healthy volunteers

被引:0
作者
Shakespeare, Joanna [1 ]
Parkes, Edward [1 ]
机构
[1] Univ Hosp Coventry & Warwickshire NHS Trust, Resp & Sleep Sci, Coventry, England
关键词
Exercise; Lung Physiology; Respiratory Measurement; PHYSICAL-ACTIVITY; LEG; CRANK; MORTALITY; RESPONSES; CAPACITY; OXYGEN; ANKLE; AGE; STATEMENT;
D O I
10.1136/bmjresp-2024-002806
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction The performance of a cardiopulmonary exercise test (CPET) requires an individual to undertake a progressive, maximal exercise test to a symptom-limited end point. CPET is commonly performed using a treadmill or cycle ergometer (CE). Arm ergometry (AE) is an alternative exercise modality to CE; however, AE produces lower peak oxygen uptake (VO2) values as it involves smaller muscle groups and generates less cardiovascular stress. Current predicted equations for the interpretation of AE CPET are limited by small sample sizes, gender bias and limited age ranges.Aims To develop predicted equations and reference ranges for AE exercise testing.Design Incremental ramp protocol CPET, to a symptom-limited end point, via AE was performed in a group of 116 (62 F) healthy volunteers of median age 38 (IQR 29-48) years. Breath-by-breath gas analysis was performed using the Ultima CPX (Medical Graphics, UK) metabolic cart. Quantile regression analysis was used to develop regression equations for AE VO2, peak work rate (WR), anaerobic threshold, peak ventilation (VE), peak heart rate, oxygen pulse, VE/VCO2 slope and VO2/WR slope.Results Reference equations including upper and/or lower limits, based on quantile regression, were generated and verified using a validation cohort.Conclusions These findings represent the largest and most diverse set of predicted values and reference ranges for AE CPET parameters in healthy individuals to date. Implementation of these reference equations will allow AE to be more widely adopted, enabling the performance and interpretation of CPET in a wider population.
引用
收藏
页数:10
相关论文
共 54 条
  • [1] Reference Values for Peak Exercise Cardiac Output in Healthy Individuals
    Agostoni, Piergiuseppe
    Vignati, Carlo
    Gentile, Piero
    Boiti, Costanza
    Farina, Stefania
    Salvioni, Elisabetta
    Mapelli, Massimo
    Magri, Damiano
    Paolillo, Stefania
    Corrieri, Nicoletta
    Sinagra, Gianfranco
    Cattadori, Gaia
    [J]. CHEST, 2017, 151 (06) : 1329 - 1337
  • [2] End-expiratory lung volume during arm and leg exercise in normal subjects and patients with cystic fibrosis
    Alison, JA
    Regnis, JA
    Donnelly, PM
    Adams, RD
    Sullivan, CE
    Bye, PTP
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (05) : 1450 - 1458
  • [3] [Anonymous], 2019, The Condition of Education 2020, Chapter 2: Postsecondary Education (Postsecondary Students), P1
  • [4] Clinician's Guide to Cardiopulmonary Exercise Testing in Adults A Scientific Statement From the American Heart Association
    Balady, Gary J.
    Arena, Ross
    Sietsema, Kathy
    Myers, Jonathan
    Coke, Lola
    Fletcher, Gerald F.
    Forman, Daniel
    Franklin, Barry
    Guazzi, Marco
    Gulati, Martha
    Keteyian, Steven J.
    Lavie, Carl J.
    Macko, Richard
    Mancini, Donna
    Milani, Richard V.
    [J]. CIRCULATION, 2010, 122 (02) : 191 - 225
  • [5] PHYSIOLOGICAL-RESPONSES TO ARM ERGOMETRY EXERCISE RELATIVE TO AGE AND GENDER
    BALADY, GJ
    WEINER, DA
    ROSE, L
    RYAN, TJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) : 130 - 135
  • [6] BARTSOKAS T W, 1989, Medicine and Science in Sports and Exercise, V21, pS87
  • [7] Automated oscillometric determination of the ankle - Brachial index provides accuracy necessary for office practice
    Beckman, JA
    Higgins, CO
    Gerhard-Herman, M
    [J]. HYPERTENSION, 2006, 47 (01) : 35 - 38
  • [8] Best C., 2020, Nurs Times, V116, P42
  • [9] Ankle blood pressure measurement, an acceptable alternative to arm measurements
    Block, FE
    Schulte, GT
    [J]. INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1996, 13 (03): : 167 - 171
  • [10] British and Irish Hypertension Society, 2021, Blood pressure monitors