Phase angle in bioelectrical impedance analysis for assessing congestion in acute heart failure

被引:0
|
作者
Sohn, Sangho [1 ]
Jeon, Jinsung [1 ]
Lee, Ji Eun [2 ]
Park, Soo Hyung [2 ]
Kang, Dong Oh [2 ]
Park, Eun Jin [2 ]
Lee, Dae-In [2 ]
Choi, Jah Yeon [2 ]
Roh, Seung Young [2 ]
Na, Jin Oh [2 ]
Choi, Cheol Ung [2 ]
Kim, Jin Won [2 ]
Rha, Seung Woon [2 ]
Park, Chang Gyu [2 ]
Sunki, Sunki [2 ]
Kim, Eung Ju [2 ]
机构
[1] Korea Univ, Dept Internal Med, Guro Hosp, Seoul, South Korea
[2] Korea Univ, Cardiovasc Ctr, Div Cardiol, Guro Hosp, Seoul, South Korea
来源
PLOS ONE | 2025年 / 20卷 / 01期
关键词
BRAIN NATRIURETIC PEPTIDE; SKELETAL-MUSCLE MASS; BIOIMPEDANCE ANALYSIS; BODY-COMPOSITION; VECTOR ANALYSIS; ACCURACY; QUANTIFICATION; DIAGNOSIS;
D O I
10.1371/journal.pone.0317333
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background The phase angle (PhA) in bioelectrical impedance analysis (BIA) reflects the cell membrane integrity or body fluid equilibrium. We examined how the PhA aligns with previously known markers of acute heart failure (HF) and assessed its value as a screening tool. Methods PhA was measured in 50 patients with HF and 20 non-HF controls along with the edema index (EI), another BIA parameter suggestive of edema. Chest computed tomography-measured lung fluid content (LFC) was used to assess pulmonary congestion. A correlation analysis was conducted to evaluate the relationships between PhA and EI, NT-proBNP, and LFC. Receiver operating characteristic (ROC) curve analysis was used to determine the cut-off values for PhA and EI for classifying patients with HF. The area under the curve (AUC) was compared using the DeLong test to evaluate the performance of PhA and EI compared to that of LFC in correctly classifying HF. Results The PhA levels were significantly lower in the HF group. Whole-body PhA was 4.49 & ring; in the HF group and 5.68 & ring; in the control group. Moderate and significant correlation was observed between PhA measured at 50-kHz and both NT-proBNP (-0.56 to-0.27, all p-values<0.05) and LFC (-0.52 to-0.41, all p-values <0.05). The AUC for whole-body PhA was 0.827 (confidence interval [CI] 0.724-0.931, p<0.01) and was 0.883 (CI 0.806-0.961, p<0.01) for EI, and the optimal cutoffs were estimated as 5 & ring; (sensitivity 0.84, specificity 0.80) and 0.394 (sensitivity 0.78, specificity 0.95), respectively. When both PhA and EI were included in the model, the AUC increased to 0.905, and this was comparable to that of LFC (AUC = 0.913, p = 0.857). Conclusions PhA exhibited a correlation with known markers of HF and demonstrated its potential as a non-invasive screening tool for the early detection of HF exacerbation. The combined use of PhA and EI can provide a robust alternative for routine self-monitoring in patients with HF, thereby enhancing early intervention.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Bioelectrical impedance analysis of body composition and survival in patients with heart failure
    Thomas, Elizabeth
    Gupta, Pritha P.
    Fonarow, Gregg C.
    Horwich, Tamara B.
    CLINICAL CARDIOLOGY, 2019, 42 (01) : 129 - 135
  • [22] Association of Bioelectrical Impedance Phase Angle with Physical Performance and Nutrient Intake of Older Adults
    Unterberger, Sandra
    Aschauer, Rudolf
    Zoehrer, Patrick A.
    Draxler, Agnes
    Aschauer, Mirjam
    Kager, Benno
    Franzke, Bernhard
    Strasser, Eva-Maria
    Wagner, Karl-Heinz
    Wessner, Barbara
    NUTRIENTS, 2023, 15 (06)
  • [23] Bioelectrical impedance analysis-derived phase angle predicts sarcopenia in patients on maintenance hemodialysis
    Wang, Ying
    Hu, Yezi
    Zhang, Mengyan
    Jin, Hui
    Wen, Yi
    Tang, Rining
    Wang, Bin
    Liu, Bicheng
    Liu, Hong
    NUTRITION IN CLINICAL PRACTICE, 2023, 38 (04) : 881 - 888
  • [24] VALUES OF THE PHASE ANGLE BY BIOELECTRICAL IMPEDANCE: NUTRITIONAL STATUS AND PROGNOSTIC VALUE
    Llames, L.
    Baldomero, V.
    Iglesias, M. L.
    Rodota, L. P.
    NUTRICION HOSPITALARIA, 2013, 28 (02) : 286 - 295
  • [25] Distribution of Bioelectrical Impedance Vector Analysis and Phase Angle in Korean Elderly and Sarcopenia
    Jiang, Fang-Lin
    Tang, Saizhao
    Eom, Seon-Ho
    Lee, Jae-Young
    Chae, Ji Heon
    Kim, Chul-Hyun
    SENSORS, 2023, 23 (16)
  • [26] Phase angle and bioelectrical impedance vector analysis in the evaluation of body composition in athletes
    Marini, Elisabetta
    Campa, Francesco
    Buffa, Roberto
    Stagi, Silvia
    Matias, Catarina N.
    Toselli, Stefania
    Sardinha, Luis B.
    Silva, Analiza M.
    CLINICAL NUTRITION, 2020, 39 (02) : 447 - 454
  • [27] Phase angle derived from bioelectrical impedance analysis as a marker for predicting sarcopenia
    Wu, Haotian
    Ding, Ping'an
    Wu, Jiaxiang
    Yang, Peigang
    Tian, Yuan
    Zhao, Qun
    FRONTIERS IN NUTRITION, 2022, 9
  • [28] Bioelectrical impedance analysis: population reference values for phase angle by age and sex
    Barbosa-Silva, MCG
    Barros, AJ
    Wang, J
    Heymsfield, SB
    Pierson, RN
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2005, 82 (01) : 49 - 52
  • [29] Bioelectrical impedance analysis (BIA)-derived phase angle in sarcopenia: A systematic review
    Di Vincenzo, Olivia
    Marra, Maurizio
    Di Gregorio, Ada
    Pasanisi, Fabrizio
    Scalfi, Luca
    CLINICAL NUTRITION, 2021, 40 (05) : 3052 - 3061
  • [30] Bioelectrical impedance vector analysis and phase angle in boys with Duchenne muscular dystrophy
    Vermeulen, Karina M.
    Lopes, Marcia M. G. D.
    Grilo, Evellyn C.
    Alves, Camila X.
    Machado, Richele J. A.
    Lais, Lucia L.
    Brandao-Neto, Jose
    Vale, Sancha H. L.
    FOOD & NUTRITION RESEARCH, 2019, 63