Dynamic characteristics test of safety class cable for nuclear power plants

被引:0
作者
Son, Jung-Dae [1 ]
Kim, Jae-Hong [2 ]
Song, Kum-Young [3 ]
Kim, Jung-Han [4 ]
机构
[1] Doosan Enerbil Co Ltd, 22 DoosanVolvo Ro, Chang Won 51711, Gyeongnam, South Korea
[2] RMS Technol Co Ltd, 55 Pungsesandan 1 Ro, Cheonan Si 31217, Chungcheongnam, South Korea
[3] Korea Hydro & Nucl Power Co Ltd, 1655 Bulguk Ro, Gyeongju Si 38120, Gyeongsangbuk D, South Korea
[4] Pusan Natl Univ, Dept Civil Engn, 2 Busandaehak Ro 63beon Gil, Busan 46241, South Korea
关键词
Nuclear power plant; Safety Class cable; Cable damping test; Cable stiffness test; Damping coefficient;
D O I
10.1016/j.net.2025.103557
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The purpose of this dynamic characteristic test is to verify that the damping ratio used in the seismic analysis of the battery connection cable that constantly stores the emergency power of a nuclear power plant is 5 % or higher, and to confirm that the structural integrity of the cable supplied to the nuclear power plant is safe. The dynamic characteristic test method of the cable was performed using the same sample as the cable installed in the battery for a nuclear power plant, and the dynamic characteristic test was performed with reference to the Korean standard (KS B ISO 7626 [1, 2, 3], KS I ISO 10846 [4], KS M 6665 [5]). The test results proved that the damping ratio of 5 % applied to the seismic analysis of cables so far is reliable.
引用
收藏
页数:7
相关论文
共 5 条
[1]  
[Anonymous], 2008, KS I ISO 10846-1
[2]  
[Anonymous], 2024, KSM6665
[3]  
[Anonymous], 2015, KS B ISO 7626-2
[4]  
[Anonymous], 1994, KS B ISO 7626-5
[5]  
[Anonymous], 2011, KS B ISO 7626-1