Rapid quantitative screening of 15 synthetic cannabinoids in urine using direct analysis in real time tandem mass spectrometry: Screening method validation and cross-correlation study with liquid chromatography tandem mass spectrometry

被引:0
作者
Covey, Jenna [1 ]
Maggitti, Alex [2 ]
Fatigante, William [1 ]
Espourteille, Francois [1 ]
Lombardo, Holly [1 ]
Bates, Terry [1 ]
机构
[1] Bruker Sci, Billerica, MA 01821 USA
[2] DrugScan, Horsham, PA 19044 USA
来源
GREEN ANALYTICAL CHEMISTRY | 2025年 / 13卷
关键词
DART-MS; Ambient ionization; Forensics and toxicology; Synthetic cannabinoids; LC-MS; Screening; Immunoassay; Chromatography-free; INTERNAL ENERGY; SAMPLES;
D O I
10.1016/j.greeac.2025.100254
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preliminary screening methods for detection of urine-based drugs of abuse are typically selected based on their ease of automation, cost effectiveness, and ability to deliver rapid results. As such, immunoassay-based testing approaches are commonly employed in routine drug screening workflows; however, these methods suffer from significant drawbacks, including cross-reactivity issues that can lead to false positives and false negatives, affecting the accuracy and reliability of results. The lack of selectivity inherent to IAs necessitates subsequent costly and time-consuming chromatography-based confirmatory testing. In this work, we report on the development of a fast, chromatography-free Direct Analysis in Real Time-tandem mass spectrometry-based (DART-MS/MS) screening approach for 15 synthetic cannabinoids and associated metabolites in urine. The proposed DART-MS/MS screening method effectively measured 15 targeted synthetic cannabinoids in 96 samples with a throughput of 23 s per sample, low limits of detection (< 1 ng/mL), high inter- and intra-day precision (<= 20 % RSD), and high accuracy (<= +/- 20 % bias). These performance metrics fall within the acceptable ranges for urine screening analyses as set forth by American National Standards Institute/Academy Standards Board (ANSI/ASB) guidelines and demonstrate performance comparable to LC-MS/MS confirmatory methods. Validation experiments with authentic urine samples confirmed positive for one or more target analytes indicated good correlation for quantitation of synthetic cannabinoids as measured by DART-MS/MS versus liquid chromatography-tandem mass spectrometry (LC-MS/MS).
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Quantitative analysis of lignocaine and metabolites in equine urine and plasma by liquid chromatography-tandem mass spectrometry
    Nelis, Samantha A.
    Sievers, Catherine
    Jarrett, Mark
    Nissen, Lisa M.
    Kirkpatrick, Carl M. J.
    Shaw, P. Nicholas
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (22): : 2018 - 2022
  • [22] Development and Validation of an Analytical Method for the Determination of Aloin Using Liquid Chromatography Tandem Mass Spectrometry
    Anagnostopoulos, Chris
    Ampadogiannis, George
    FOOD ANALYTICAL METHODS, 2020, 13 (07) : 1409 - 1420
  • [23] Rapid differentiation and quality control of tobacco products using Direct Analysis in Real Time Mass Spectrometry and Liquid Chromatography Mass Spectrometry
    Losso, Klemens
    Cardini, Julian
    Huber, Susanne
    Kappacher, Christoph
    Jakschitz, Thomas
    Rainer, Matthias
    Bonn, Gunther K.
    TALANTA, 2022, 238
  • [24] Rapid and reliable analysis of underivatized amino acids in urine using tandem mass spectrometry
    Fern, Maria Teresa
    Casas-Ferreira, Ana Maria
    Rodriguez-Gonzalo, Encarnacion
    Moreno-Cordero, Bernardo
    Luis Perez-Pavon, Jose
    MICROCHEMICAL JOURNAL, 2022, 172
  • [25] Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography-Tandem Mass Spectrometry and Liquid Chromatography-Tandem Mass Spectrometry
    Lipicar, Eva
    Fras, Danijela
    Javernik, Nino
    Prosen, Helena
    TOXICS, 2023, 11 (01)
  • [26] Rapid screening of 176 pesticide residues in vegetables by ultra fast liquid chromatography-tandem mass spectrometry
    Zheng Shuning
    Li Lingyun
    Lin Huan
    Zhao Wen
    Zhang Yanguo
    Yao Zhoulin
    Liu Su
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (01) : 71 - 78
  • [27] Simple and rapid screening procedure for 143 new psychoactive substances by liquid chromatography-tandem mass spectrometry
    Adamowicz, Piotr
    Tokarczyk, Bogdan
    DRUG TESTING AND ANALYSIS, 2016, 8 (07) : 652 - 667
  • [28] Quantitative determination of taurine and related biomarkers in urine by liquid chromatography-tandem mass spectrometry
    Gamagedara, Sanjeewa
    Shi, Honglan
    Ma, Yinfa
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (02) : 763 - 770
  • [29] Screening and confirmation methods of the major urinary metabolite of finasteride carboxy-finasteride by liquid chromatography mass spectrometry and liquid chromatography tandem mass spectrometry
    Zhang, Jianli
    ACTA PHARMACEUTICA SINICA B, 2012, 2 (02) : 220 - 226
  • [30] Sensitive screening of synthetic cannabinoids using liquid chromatography quadrupole time-of-flight mass spectrometry after solid phase extraction
    Kleis, Jan-Niklas
    Hess, Cornelius
    Germerott, Tanja
    Roehrich, Joerg
    DRUG TESTING AND ANALYSIS, 2021, 13 (08) : 1535 - 1551