Rapid quantitative screening of 15 synthetic cannabinoids in urine using direct analysis in real time tandem mass spectrometry: Screening method validation and cross-correlation study with liquid chromatography tandem mass spectrometry

被引:0
|
作者
Covey, Jenna [1 ]
Maggitti, Alex [2 ]
Fatigante, William [1 ]
Espourteille, Francois [1 ]
Lombardo, Holly [1 ]
Bates, Terry [1 ]
机构
[1] Bruker Sci, Billerica, MA 01821 USA
[2] DrugScan, Horsham, PA 19044 USA
来源
GREEN ANALYTICAL CHEMISTRY | 2025年 / 13卷
关键词
DART-MS; Ambient ionization; Forensics and toxicology; Synthetic cannabinoids; LC-MS; Screening; Immunoassay; Chromatography-free; INTERNAL ENERGY; SAMPLES;
D O I
10.1016/j.greeac.2025.100254
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preliminary screening methods for detection of urine-based drugs of abuse are typically selected based on their ease of automation, cost effectiveness, and ability to deliver rapid results. As such, immunoassay-based testing approaches are commonly employed in routine drug screening workflows; however, these methods suffer from significant drawbacks, including cross-reactivity issues that can lead to false positives and false negatives, affecting the accuracy and reliability of results. The lack of selectivity inherent to IAs necessitates subsequent costly and time-consuming chromatography-based confirmatory testing. In this work, we report on the development of a fast, chromatography-free Direct Analysis in Real Time-tandem mass spectrometry-based (DART-MS/MS) screening approach for 15 synthetic cannabinoids and associated metabolites in urine. The proposed DART-MS/MS screening method effectively measured 15 targeted synthetic cannabinoids in 96 samples with a throughput of 23 s per sample, low limits of detection (< 1 ng/mL), high inter- and intra-day precision (<= 20 % RSD), and high accuracy (<= +/- 20 % bias). These performance metrics fall within the acceptable ranges for urine screening analyses as set forth by American National Standards Institute/Academy Standards Board (ANSI/ASB) guidelines and demonstrate performance comparable to LC-MS/MS confirmatory methods. Validation experiments with authentic urine samples confirmed positive for one or more target analytes indicated good correlation for quantitation of synthetic cannabinoids as measured by DART-MS/MS versus liquid chromatography-tandem mass spectrometry (LC-MS/MS).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Rapid screening of 23 synthetic cannabinoids in blood by direct analysis in real time-Tandem mass spectrometry
    Ji, Jiahua
    Wang, Jifen
    Zhang, Ying
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 469
  • [2] Ultrafast Screening of Synthetic Cannabinoids and Synthetic Cathinones in Urine by RapidFire-Tandem Mass Spectrometry
    Neifeld, Jillian R.
    Regester, Laura E.
    Holler, Justin M.
    Vorce, Shawn P.
    Magluilo, Joseph, Jr.
    Ramos, Gerardo
    Bosy, Thomas Z.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (05) : 379 - 387
  • [3] Simple screening procedure for 72 synthetic cannabinoids in whole blood by liquid chromatography–tandem mass spectrometry
    Katarzyna Ambroziak
    Piotr Adamowicz
    Forensic Toxicology, 2018, 36 : 280 - 290
  • [4] Optimization of a rapid method for screening drugs in blood by liquid chromatography tandem mass spectrometry
    Valero, Alba M. Rodrigo
    Jorge, Oscar Quintela
    Serrano, Begona Bravo
    Tejedor, Sara Ayuso
    ADVANCES IN LABORATORY MEDICINE-AVANCES EN MEDICINA DE LABORATORIO, 2023, 4 (04): : 365 - 371
  • [5] Liquid chromatography-tandem mass spectrometry screening method using information-dependent acquisition of enhanced product ion mass spectra for synthetic cannabinoids including metabolites in urine
    Staeheli, Sandra N.
    Veloso, Veronica P.
    Bovens, Michael
    Bissig, Christian
    Kraemer, Thomas
    Poetzsch, Michael
    DRUG TESTING AND ANALYSIS, 2019, 11 (09) : 1369 - 1376
  • [6] Simple screening procedure for 72 synthetic cannabinoids in whole blood by liquid chromatography-tandem mass spectrometry
    Ambroziak, Katarzyna
    Adamowicz, Piotr
    FORENSIC TOXICOLOGY, 2018, 36 (02) : 280 - 290
  • [7] Rapid detection of nine synthetic cathinones in blood and urine by direct analysis in real-time-tandem mass spectrometry
    Ji, Jiahua
    Zhang, Ying
    Wang, Jifen
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (15)
  • [8] Screening of Stimulants Including Designer Drugs in Urine Using a Liquid Chromatography Tandem Mass Spectrometry System
    O'Byrne, Paul M.
    Kavanagh, Pierce V.
    McNamara, Sinead M.
    Stokes, Siobhan M.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2013, 37 (02) : 64 - 73
  • [9] Development and validation of a qualitative screening method for the detection of exogenous anabolic steroids in urine by liquid chromatography-tandem mass spectrometry
    Pozo, Oscar J.
    Van Eenoo, Peter
    Deventer, Koen
    Delbeke, Frans T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (04) : 1209 - 1224
  • [10] Development and validation of a qualitative screening method for the detection of exogenous anabolic steroids in urine by liquid chromatography-tandem mass spectrometry
    Oscar J. Pozo
    Peter Van Eenoo
    Koen Deventer
    Frans T. Delbeke
    Analytical and Bioanalytical Chemistry, 2007, 389 : 1209 - 1224