Experimental and analytical investigations of the dynamic characteristics of a mold transformer with rotary friction dampers based on shaking table tests

被引:0
作者
Lee, Seung-Jae [1 ]
Lee, Ji-Eon [1 ]
Dinh, Ngoc Hieu [1 ]
Choi, Kyoung-Kyu [1 ]
机构
[1] Soongsil Univ, Sch Architecture, 369 Sangdo Ro, Seoul 06978, South Korea
基金
新加坡国家研究基金会;
关键词
mold transformer; dynamic characteristics; shaking table test; rotary friction dampers; dynamic structural model; stiffness calibration; SEISMIC PERFORMANCE EVALUATION; EARTHQUAKE; FRAMES;
D O I
10.1007/s11803-025-2318-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, shaking table tests were performed to investigate the dynamic characteristics of a mold transformer. Based on the test results, rotary friction dampers were developed to mitigate the excessive lateral displacement that occurred along the direction of the weak stiffness axis of the mold transformer. In addition, shaking table tests were performed by attaching friction dampers to both sides of the mold transformer. Based on the shaking table test results, the natural frequency, mode vector, and damping ratio of the mold transformer were derived using the transfer function and half-power bandwidth. The test results indicated that the use of friction dampers can decrease the displacement and acceleration response of the mold transformer. Finally, dynamic structural models were established considering the component connectivity and mass distribution of the mold transformer. In addition, a numerical strategy was proposed to calibrate the stiffness coefficients of the mold transformer, thereby facilitating the relationship between generalized mass and stiffness. The results indicated that the analytical model based on the calibration strategy of stiffness coefficients can reasonably simulate the dynamic behavior of the mold transformer using friction dampers with regard to transfer function, displacement, and acceleration response.
引用
收藏
页码:451 / 472
页数:22
相关论文
共 41 条
[31]   Life-cycle cost evaluation of steel structures retrofitted with steel slit damper and shape memory alloy-based hybrid damper [J].
NourEldin, Mohamed ;
Naeem, Asad ;
Kim, Jinkoo .
ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (01) :3-16
[32]   COMPARATIVE STUDY OF SEISMIC TESTING METHODS [J].
PALK, BV ;
HAWLEY, JW ;
IBANEZ, P .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, PA94 (03) :1003-1012
[33]   Seismic reliability of electrical power transmission systems [J].
Pires, JA ;
Ang, AHS ;
Villaverde, R .
NUCLEAR ENGINEERING AND DESIGN, 1996, 160 (03) :427-439
[34]   Scissor-jack-damper energy dissipation system [J].
Sigaher, AN ;
Constantinou, MC .
EARTHQUAKE SPECTRA, 2003, 19 (01) :133-158
[35]  
Sivan DD, 1996, COMMUN NUMER METH EN, V12, P531
[36]  
Tanaka S., 1997, Proceedings of The Northridge Earthquake Research Conference, P20
[37]   Accuracy of the half-power bandwidth method with a third-order correction for estimating damping in multi-DOF systems [J].
Wang Jinting ;
Lu Dandan ;
Jin Feng ;
Zhang Chuhan .
EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2013, 12 (01) :33-38
[38]   Earthquake performance of porcelain transformer bushings [J].
Whittaker, AS ;
Fenves, GL ;
Gilani, ASJ .
EARTHQUAKE SPECTRA, 2004, 20 (01) :205-223
[39]  
Xie QA, 2011, IEEE POWER ENERGY M, V9, P29
[40]  
Xu ZD, 2003, J INTEL MAT SYST STR, V14, P35, DOI 10.1177/104538903033642