Efficacy of CEUS-guided biopsy for thoracic and pulmonary lesions: a systematic review and meta-analysis

被引:0
作者
Sun, Zhe [1 ,2 ]
Yu, Xuejiao [1 ,2 ]
Ma, Jiaojiao [1 ,3 ]
Zhou, Tongtong [1 ,2 ]
Zhang, Bo [3 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, China Japan Friendship Hosp, Inst Clin Med Sci, Beijing 100730, Peoples R China
[2] China Japan Friendship Hosp, Dept Ultrasound, Beijing 100029, Peoples R China
[3] Chinese Acad Med Sci, China Japan Friendship Hosp, Natl Ctr Resp Med, Natl Clin Res Ctr Resp Dis,Inst Resp Med,Dept Ultr, Beijing 100029, Peoples R China
关键词
Contrast-enhanced ultrasound; Percutaneous transthoracic needle biopsy; Thoracic diseases; Success rate; Diagnostic accuracy; Adverse effects; Meta-analysis; CONTRAST-ENHANCED ULTRASOUND; TRANSTHORACIC NEEDLE-BIOPSY; PERIPHERAL LUNG; CLINICAL-VALUE; TIME;
D O I
10.1186/s12880-025-01700-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThis study compares the success rate, diagnostic accuracy, and safety of contrast-enhanced ultrasound (CEUS)-guided biopsy versus conventional ultrasound (US)-guided biopsy for thoracic and pulmonary lesions.MethodsA systematic search of PubMed, EMBASE, Web of Science, and Cochrane Library was conducted. The primary outcomes included success rate and diagnostic accuracy, and the secondary outcome was the odds ratio of adverse effects. A random-effects meta-analysis pooled the data, with heterogeneity assessed by I-2 and publication bias evaluated using Egger's test and funnel plot analysis. Sensitivity analysis was performed to confirm result robustness. Subgroup analysis and meta-regression were conducted to explore the sources of heterogeneity.ResultsSixteen studies with 3,459 patients were included. CEUS-guided biopsy demonstrated higher success rate (99.18%, 95% CI: 98.00-99.90%) and diagnostic accuracy (95.96%, 95% CI: 94.84-96.96%) than US-guided biopsy (success rate: 97.26%, 95% CI: 95.45-98.68%; diagnostic accuracy: 85.87%, 95% CI: 82.05-89.31%). Complications were more frequent in the US-guided group, with an odds ratio of 1.65 (95% CI: 1.15-2.37). Heterogeneity was low, and publication bias was minimal, except for diagnostic accuracy in the US group. Sensitivity analysis confirmed result robustness.ConclusionCompared with conventional ultrasound, CEUS-guided biopsy demonstrates a comparable success rate, superior diagnostic accuracy, and a lower incidence of complications, underscoring its clinical value as a preferred approach for thoracic and pulmonary lesion assessment.Systematic review registrationThis study was registered with PROSPERO under the registration number CRD42024608627.Clinical trial numberNot applicable.
引用
收藏
页数:12
相关论文
共 34 条
[1]  
Atkins D, 2004, BMJ-BRIT MED J, V328, P1490
[2]   Application value of contrast-enhanced ultrasound in the diagnosis of peripheral pulmonary focal lesions [J].
Bai, Zina ;
Liu, Tong ;
Liu, Wei ;
Li, Zhensheng ;
Zheng, Hao ;
Li, Xingbin .
MEDICINE, 2022, 101 (29) :E29605
[3]   US Contrast Agent Arrival Time Difference Ratio for Benign versus Malignant Subpleural Pulmonary Lesions [J].
Bi, Ke ;
Zhou, Rui-rui ;
Zhang, Yi ;
Shen, Meng-jun ;
Chen, Hong-wei ;
Cong, Yang ;
Zhu, Hui-ming ;
Tang, Chun-hong ;
Yuan, Jing ;
Wang, Yin .
RADIOLOGY, 2021, 301 (01) :200-210
[4]   Sonographically Guided Transthoracic Biopsy of Peripheral Lung and Mediastinal Lesions Role of Contrast-Enhanced Sonography [J].
Cao, Bing-Sheng ;
Wu, Ji-Hua ;
Li, Xiao-Lin ;
Deng, Juan ;
Liao, Guo-Qing .
JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (11) :1479-1490
[5]  
Fan Peili, 2022, J Interv Med, V5, P159, DOI 10.1016/j.jimed.2022.04.006
[6]   Clinical value of contrast-enhanced ultrasound in improving diagnostic accuracy rate of transthoracic biopsy of anteriormedial mediastinal lesions [J].
Fu, Jingjing ;
Yang, Wei ;
Wang, Song ;
Bai, Jing ;
Wu, Hao ;
Wang, Haiyue ;
Yan, Kun ;
Chen, Minhua .
CHINESE JOURNAL OF CANCER RESEARCH, 2016, 28 (06) :617-625
[7]   ULTRASOUND-GUIDED PERCUTANEOUS NEEDLE BIOPSY FOR PERIPHERAL PULMONARY LESIONS: DIAGNOSTIC ACCURACY AND INFLUENCING FACTORS [J].
Guo, Yu-Qing ;
Liao, Xin-Hong ;
Li, Zhi-Xian ;
Chen, Yuan-Yuan ;
Wang, Si-Da ;
Wang, Ji-Han ;
Liao, Xian-Shan ;
Luo, Yuan .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (05) :1003-1011
[8]   Clinical value of contrast-enhanced ultrasound in transthoracic biopsy of malignant anterior mediastinal masses [J].
Han, Jie ;
Feng, Xiao-Li ;
Xu, Tian-Yu ;
Feng, Wen-Qi ;
Liu, Meng-Jia ;
Wang, Bo ;
Qiu, Ting-Lin ;
Wang, Yong .
JOURNAL OF THORACIC DISEASE, 2019, 11 (12) :5290-5299
[9]   Quantifying heterogeneity in a meta-analysis [J].
Higgins, JPT ;
Thompson, SG .
STATISTICS IN MEDICINE, 2002, 21 (11) :1539-1558
[10]   The Cochrane Collaboration's tool for assessing risk of bias in randomised trials [J].
Higgins, Julian P. T. ;
Altman, Douglas G. ;
Gotzsche, Peter C. ;
Jueni, Peter ;
Moher, David ;
Oxman, Andrew D. ;
Savovic, Jelena ;
Schulz, Kenneth F. ;
Weeks, Laura ;
Sterne, Jonathan A. C. .
BMJ-BRITISH MEDICAL JOURNAL, 2011, 343