Multi-center evaluation of the Selux next-generation phenotyping system for gram-negative direct-from-positive blood culture antimicrobial susceptibility testing

被引:0
作者
Streva, Vincent [1 ]
Gajewski, Joseph [2 ]
Pento, Jacqueline [1 ]
Chandrasekaran, Alamelu [3 ]
Green, Matt [2 ]
Lindley, Jill [4 ]
Huband, Micahel [4 ]
El Ganbour, Asmae [5 ]
Roberts, Kristen [5 ]
Flentie, Kelly [5 ]
Sherman, Jingzi [5 ]
Stern, Eric [5 ]
Berry, Gregory J. [3 ]
机构
[1] Northwell Heath, New York, NY USA
[2] Element, Acton, MA USA
[3] Columbia Univ, Ctr Adv Lab Med, Dept Pathol & Cell Biol, Irving Med Ctr, New York, NY 10032 USA
[4] Element Iowa City JMI Labs, North Liberty, IA USA
[5] Selux Diagnost, Charlestown, MA USA
关键词
rapid diagnostics; multi-drug resistance; antimicrobial susceptibility test; blood culture; SEPSIS; ANTIBIOTICS; RESISTANCE; MORTALITY;
D O I
10.1128/jcm.01819-24
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Accurate and rapid antimicrobial susceptibility test (AST) results from positive blood cultures are crucial for patient care and combatting antimicrobial resistance. Although recent advancements in rapid direct-from-positive blood culture (PBC) identification platforms have enabled the provision of species-level identification and some resistance marker information within hours after blood culture positivity, AST results required for clinical decision-making often require 48 h after blood culture positivity. This study evaluated the Selux next-generation phenotyping system, including an automated PBC Separator and the Selux AST system in a multicenter clinical trial for their ability to perform AST directly from PBCs for gram-negative bacilli. The PBC separator produces McFarland equivalent inocula from positive blood cultures within 1 h, facilitating direct processing on the Selux AST system. The study evaluated 162 fresh clinical PBC samples, 307 seeded clinical samples, and 87 seeded challenge samples across 4 sites for each of the 17 antimicrobials included in the panel. The results demonstrate that the Selux system's clinical performance, reproducibility, and analytical performances are consistent when using positive blood cultures held for up to 16 h after positivity on the BACTEC and BacT/ALERT 3D and BacT/ALERT VIRTUO blood culture systems, including all major BACTEC and BacT/ALERT blood culture bottle types. These findings suggest that the PBC Separator with the Selux AST system is a valuable addition to the arsenal of tools available for rapid sepsis diagnosis and management.
引用
收藏
页数:14
相关论文
共 48 条
  • [41] Evaluation of a sterile, filter-based, in-house method for rapid direct bacterial identification and antimicrobial susceptibility testing using positive blood culture
    Keun Ju Kim
    Seung Gyu Yun
    Yunjung Cho
    Myung-Hyun Nam
    Young Jin Ko
    Chang Kyu Lee
    European Journal of Clinical Microbiology & Infectious Diseases, 2023, 42 : 691 - 700
  • [42] Evaluation of a sterile, filter-based, in-house method for rapid direct bacterial identification and antimicrobial susceptibility testing using positive blood culture
    Kim, Keun Ju
    Yun, Seung Gyu
    Cho, Yunjung
    Nam, Myung-Hyun
    Ko, Young Jin
    Lee, Chang Kyu
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2023, 42 (06) : 691 - 700
  • [43] Direct antimicrobial susceptibility testing (AST) from positive blood cultures using Microscan system for early detection of bacterial resistance phenotypes
    Quirino, A.
    Marascio, N.
    Peronace, C.
    Gallo, L.
    Barreca, G. S.
    Giancotti, A.
    Lamberti, A. G.
    Colosimo, M.
    Minchella, P.
    Trecarichi, E. M.
    Torti, C.
    Liberto, M. C.
    Matera, G.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2021, 101 (02)
  • [44] Evaluation of antimicrobial susceptibility testing directly from positive blood cultures using the Vitek 2 system: comparison of two rapid protocols
    Porte, Lorena
    Gattini, Francesca
    Varela, Carmen
    Weitzel, Thomas
    REVISTA CHILENA DE INFECTOLOGIA, 2017, 34 (02): : 190 - +
  • [45] Evaluation of the Accelerate Pheno System for Rapid Identification and Antimicrobial Susceptibility Testing of Positive Blood Culture Bottles Inoculated with Primary Sterile Specimens from Patients with Suspected Severe Infections
    Chapot, V
    Effenberg, L.
    Dohmen-Ruetten, J.
    Buer, J.
    Kehrmann, J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (05)
  • [46] Rapid Antimicrobial Susceptibility Testing Using the MicroScan System: Performance Evaluation of a 4-Hour Bacterial Cultivation From Positive Blood Cultures
    Krueger, Alexander
    Koerber-Irrgang, Barbara
    Flueh, Greta
    Gielen, Joerg
    Scholz, Claus-Juergen
    Wisplinghoff, Hilmar
    Jazmati, Nathalie
    CURRENT MICROBIOLOGY, 2024, 81 (08)
  • [47] Evaluation of Quantamatrix dRASTTM system for rapid antimicrobial susceptibility testing of bacterial isolates from positive blood cultures, in comparison with commercial Micronaut broth microdilution system
    Morecchiato, Fabio
    Coppi, Marco
    Chilleri, Chiara
    Antonelli, Alberto
    Giani, Tommaso
    Rossolini, Gian Maria
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2024, 110 (01)
  • [48] Direct MALDI-TOF MS and Antimicrobial Susceptibility Testing of Positive Blood Cultures Using the FAST™ System and FAST-PBC Prep Cartridges-Performance Evaluation in a Clinical Microbiology Laboratory Serving High-Risk Patients
    Ugaban, Khay
    Pak, Pil
    She, Rosemary C.
    MICROORGANISMS, 2022, 10 (10)