Occupational radiation exposure during blood sample collection post I-131 therapeutic administration in thyroid cancer patients

被引:0
|
作者
Al Jabri, Amna [1 ,2 ]
Cooke, Jennie [3 ]
Cournane, Sean [4 ]
Healy, Marie-Louise [5 ]
机构
[1] Sultan Qaboos Univ, Muscat, Oman
[2] Trinity Coll Dublin, Dublin, Ireland
[3] Childrens Hlth Ireland Crumlin, Dublin, Ireland
[4] St Vincents Univ Hosp, Dublin, Ireland
[5] St James Hosp, Dublin, Ireland
关键词
radiation protection; occupational exposure; I-131; radioiodine; dosimetry; thyroid cancer; risk assessment; RECEIVING I-131; CARCINOMA; DOSIMETRY;
D O I
10.1088/1361-6498/adc8b3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The blood sampling required for the verification of dose delivered during radioactive iodine (I-131) therapy is a source of radiation exposure for healthcare staff. This study aims to estimate staff exposures, using Monte Carlo modelling, as well as experimental measurements. The study further aimed to validate the models with staff exposure measurements and examine the impact of protective measures on the procedure. The clinical set-up of blood sampling post I-131 patient administration, within a dedicated I-131 ablation therapy suite, was modelled using EGSnrc Monte Carlo simulations (MCSs). The dose scoring regions representing deep dose (Hp(10)) and skin dose (Hp(0.07)) were estimated and validated with an experimental approach and clinical monitoring of staff members using electronic personal dosimeters. MCSs and experimental values did not show significant differences between the two approaches (p > 0.05), with simulated values having lower uncertainties. It is demonstrated that the model is capable of being tailored to clinical scenarios at any centre. The simulations were corroborated with dosimetry data of blood sampling from 14 patients post administering 3.7 GBq I-131, amounting to a total of 54 measurements from 14 staff members. With the employed protective shielding, none of the staff were exposed to a dose rate approaching the annual dose constraint of 0.3 mSv.yr(-1). The experimental and MCS data show good agreement with the clinical data, demonstrating the advantages of MCS approaches for providing useful information for planning and carrying out risk assessments before implementing a new dosimetry practice.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] PREGNANCY AFTER HIGH THERAPEUTIC DOSES OF I-131 IN DIFFERENTIATED THYROID-CANCER - POTENTIAL RISKS AND RECOMMENDATIONS
    CASARA, D
    RUBELLO, D
    SALADINI, G
    PIOTTO, A
    PELIZZO, MR
    GIRELLI, ME
    BUSNARDO, B
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1993, 20 (03): : 192 - 194
  • [22] Differentiated thyroid cancer patients potentially benefitting from postoperative I-131 therapy: a review of the literature of the past decade
    Verburg, Frederik A.
    Flux, Glenn
    Giovanella, Luca
    van Nostrand, Douglas
    Muylle, Kristoff
    Luster, Markus
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (01) : 78 - 83
  • [23] Diffuse soft tissue uptake of I-131 after post-thyroidectomy ablation therapy for thyroid cancer
    Song, HC
    Heo, YJ
    Kim, SM
    Bom, HS
    CLINICAL NUCLEAR MEDICINE, 2002, 27 (03) : 215 - 215
  • [24] Radiation Dose-rate Reduction Pattern in Well-differentiated Thyroid Cancer Treated with I-131
    Khan, Shahbaz Ahmad
    Khan, Muhammad Saqib
    Arif, Muhammad
    Durr-e-Sabih
    Rahim, Muhammad Kashif
    Ahmad, Israr
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2015, 25 (07): : 510 - 513
  • [25] Estimation of the release time from isolation for patients with differentiated thyroid cancer treated with high-dose I-131
    Lee J.H.
    Park S.G.
    Nuclear Medicine and Molecular Imaging, 2010, 44 (4) : 241 - 245
  • [26] Comparison of 30 mCi and 50 mCi I-131 doses for ablation of thyroid remnant in papillary thyroid cancer patients
    Cai, Xiao Yue
    Vijayaratnam, Niranjan
    McEwan, Alexander J. B.
    Reif, Rebecca
    Morrish, Donald W.
    ENDOCRINE RESEARCH, 2018, 43 (01) : 11 - 14
  • [27] Releasing thyroid cancer patients from the hospital based on dose rate measurement after 131I activity administration
    Hewamanna, R.
    Loganathan, Naalini
    Perera, D. K. A.
    JOURNAL OF THE NATIONAL SCIENCE FOUNDATION OF SRI LANKA, 2014, 42 (02): : 137 - 141
  • [28] Clinical applications of SPECT/CT after first I-131 ablation in patients with differentiated thyroid cancer
    Jeong, Shin Young
    Lee, Sang-Woo
    Kim, Hae Won
    Song, Bong-Il
    Ahn, Byeong-Cheol
    Lee, Jaetae
    CLINICAL ENDOCRINOLOGY, 2014, 81 (03) : 445 - 451
  • [29] Benign Epithelial Cyst Mimicking Thyroid Cancer Metastasis A False-Positive Finding on Post-Therapy I-131 Scan
    Bural, Gonca Gul
    Peel, Robert L.
    Mountz, James M.
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (01) : 88 - 90
  • [30] Comparisons of I-123 diagnostic and I-131 post-treatment scans for detecting residual thyroid tissue and metastases of differentiated thyroid cancer
    Shingo Iwano
    Katsuhiko Kato
    Takashi Nihashi
    Shinji Ito
    Yasushi Tachi
    Shinji Naganawa
    Annals of Nuclear Medicine, 2009, 23 : 777 - 782