Should the load-to-fracture test for CAD/CAM monolithic molar crowns be standardized and how? A systematic review and finite element analysis

被引:0
|
作者
Miranda, Nicole Cindy Fontinele [1 ]
Gialain, Ivan Onone [2 ]
Gantier-Takano, Marlene Kasumi [1 ]
Ballester, Rafael Yague [1 ]
Hernandez, Bruno Agostinho [3 ]
Fok, Alex [4 ]
Meira, Josete Barbosa Cruz [1 ,5 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Biomat & Oral Biol, Sao Paulo, SP, Brazil
[2] Univ Cuiaba, Sch Dent, Cuiaba, Brazil
[3] Sao Paulo State Univ, Sch Engn, Dept Mech Engn, Bauru, SP, Brazil
[4] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Sch Dent, Minneapolis, MN 55455 USA
[5] Univ Sao Paulo, Sch Dent, Dept Biomat & Oral Biol, Av Prof Lineu Prestes 2227, BR-05508000 Sao Paulo, SP, Brazil
关键词
IN-VITRO PERFORMANCE; ALL-CERAMIC CROWNS; CAD-CAM; LITHIUM DISILICATE; MECHANICAL-PROPERTIES; ZIRCONIA CROWNS; ENDOCROWN RESTORATIONS; MARGINAL ADAPTATION; FAILURE LOAD; RESISTANCE;
D O I
10.1016/j.jmbbm.2025.106984
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The load-to-fracture test is widely used to evaluate crowns made of new CAD/CAM materials, even though its validity in predicting clinical performances is often questioned. Despite its limitations, the test is useful in assessing the load-bearing capacity of crowns subjected to accidental overloads and setting up step-stress regimes for fatigue testing. This study combined a systematic review (SR) and finite element analysis (FEA) to assess whether the test should be standardized and how. The SR evaluated load-to-fracture studies of monolithic CAD/CAM molar crowns published in Q1 and Q2 journals. Findings from 85 studies highlighted the lack of standardization in test methods, particularly regarding loading head type and die material. This variability led to a wide dispersion of fracture load results, limiting the utility of the load-to-fracture test. The FEA evaluated the influence of loading head type and die material on tensile stress distribution in lithium disilicate (LD) and polymer-infiltrated ceramic network (PICN) crowns. Eight in vitro conditions were simulated, varying the loading head (4 mm and 10 mm spheres, inverse V-shaped device, opposing teeth) and die material (stiff, E = 207 GPa; non-stiff, E = 13 GPa). The FEA confirmed that the stress distribution and peak tensile stress in LD and PICN crowns depend significantly on these factors as well as the crown material properties, with the peak stress variation from LD to PICN ranging from-4 % to 237 %. Using larger-diameter spheres with a die material approximating dentin in stiffness resulted in stress distributions more representative of clinical conditions.
引用
收藏
页数:15
相关论文
共 21 条
  • [1] Fracture analysis of monolithic CAD-CAM crowns
    Kashkari, Afnan
    Yilmaz, Burak
    Brantley, William A.
    Schricker, Scott R.
    Johnston, William M.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (04) : 346 - 352
  • [2] Fracture Load of Monolithic CAD/CAM Ceramic Crowns Placed on Different Implant Abutments
    Meneghetti, Priscila Ceolin
    Pittas do Canto, Paulo Eduardo
    Spohr, Ana Maria
    Burnett Junior, Luiz Henrique
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1217 - 1222
  • [3] Fracture Load of Monolithic CAD/CAM Lithium Disilicate Ceramic Crowns and Veneered Zirconia Crowns as a Posterior Implant Restoration
    Kim, Jee Hwan
    Lee, Su-Jeong
    Park, Jun Sub
    Ryu, Jae Jun
    IMPLANT DENTISTRY, 2013, 22 (01) : 66 - 70
  • [4] In vitro analysis of the fracture resistance of CAD-CAM monolithic zirconia molar crowns with different occlusal thickness
    Sorrentino, Roberto
    Triulzio, Clementina
    Tricarico, Maria Gabriella
    Bonadeo, Giovanni
    Gherlone, Enrico Felice
    Ferrari, Marco
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 61 : 328 - 333
  • [5] Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions
    Choi, Sulki
    Yoon, Hyung-In
    Park, Eun-Jin
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (06) : 423 - 431
  • [6] In vitro analysis of the fracture resistance of CAD-CAM monolithic lithium disilicate molar crowns with different occlusal thickness
    Sorrentino, R.
    Nagasawa, Y.
    Infelis, M.
    Bonadeo, G.
    Ferrari, M.
    JOURNAL OF OSSEOINTEGRATION, 2018, 10 (02) : 50 - 56
  • [7] Effect of Reduced Material Thickness on Fatigue Behavior and Failure Load of Monolithic CAD/CAM PICN Molar Crowns
    Gierthmuehlen, Petra
    Ruebel, Alexander
    Stampf, Susanne
    Spitznagel, Frank
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (01) : 71 - 74
  • [8] In Vitro Study of Fracture Load and Fracture Pattern of Ceramic Crowns: A Finite Element and Fractography Analysis
    Campos, Roberto Elias
    Soares, Carlos Jose
    Quagliatto, Paulo S.
    Soares, Paulo Vinicius
    de Oliveira Junior, Osmir Batista
    Freitas Santos-Filho, Paulo Cesar
    Salazar-Marocho, Susana M.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (06): : 447 - 455
  • [9] CAD/CAM Glass Ceramics for Single-Tooth Implant Crowns: A Finite Element Analysis
    Akca, Kivanc
    Cavusoglu, Yeliz
    Sagirkaya, Elcin
    Aybar, Buket
    Cehreli, Murat Cavit
    IMPLANT DENTISTRY, 2013, 22 (06) : 623 - 626
  • [10] Fracture Resistance of Molar Crowns Fabricated with Monolithic All-Ceramic CAD/CAM Materials Cemented on Titanium Abutments: An In Vitro Study
    Dogan, Derya Ozdemir
    Gorler, Oguzhan
    Mutaf, Burcu
    Ozcan, Mutlu
    Eyuboglu, Gunes Bulut
    Ulgey, Melih
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (04): : 309 - 314