Effect of powder preparation on degradation behavior and cytotoxicity of sintered porous biodegradable FeMnC alloys for biomedical applications

被引:0
作者
Cherqaoui, Abdelhakim [1 ]
Copes, Francesco [1 ]
Paternoster, Carlo [1 ]
Gelinas, Simon [2 ]
Mengucci, Paolo [3 ,4 ]
Blais, Carl [2 ]
Mantovani, Diego [1 ]
机构
[1] Univ Laval, Univ Hosp Res Ctr Regenerat Med, Dept Min Met Mat Eng, Lab Biomat & Bioengn,CRC I, Quebec City, PQ G1V 0A6, Canada
[2] Univ Laval, Dept Min Met Mat Engn, Lab Powder Met, Quebec City, PQ, Canada
[3] Univ Politecn Marche, Dept SIMAU, Via Brecce Bianche 12, I-60131 Ancona, Italy
[4] Univ Politecn Marche, UdR INSTM, Via Brecce Bianche 12, I-60131 Ancona, Italy
来源
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY | 2025年 / 236卷
关键词
Biodegradable FeMnC alloys; Powder metallurgy; Mechanical-milling; Degradation; Cell viability; Hemolysis; IN-VITRO DEGRADATION; FE-MN ALLOYS; MECHANICAL-PROPERTIES; PURE IRON; TENSILE PROPERTIES; ELECTROCHEMICAL-BEHAVIOR; CORROSION; MICROSTRUCTURE; BIOCOMPATIBILITY; DENSIFICATION;
D O I
10.1016/j.jmst.2025.03.016
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Biodegradable implants have emerged in biomedical applications, particularly for orthopedic fixations, cardiovascular stents, and tissue engineering scaffolds. Unlike permanent implants, they are designed to degrade and be reabsorbed after implantation in the body, mitigating the need for additional surgeries and reducing associated complications. In particular, Fe-Mn-C alloys constitute a new class of promising metallic materials for medical applications due to their outstanding mechanical properties and their biological performances. This study focuses on improving the degradation rates and cytotoxicity of sintered Fe-Mn-C alloys produced using the powder metallurgy process. To evaluate the impact of different powder preparation methods on material properties, two types of powders were used: (1) MX, prepared by mixing Fe, Mn, and C powders for 1 h; and (2) MM, obtained by mechanically milling the same powders for 10 h. Four mixtures with varying proportions of MX and MM were prepared. Two groups of samples were produced: one entirely from MX (A0), and another containing MM at 25 wt.% (A25), 50 wt.% (A50), and 75 wt.% (A75). All samples exhibited a complex microstructure comprising ferrite, martensite, and residual austenite. Degradation behavior assessment in Hanks' solution over 14 days showed that adding MM increased the degradation rate, from around 0.04 mmpy for A0 to 0.12 mmpy for A25. Notably, all samples showed similar cell viability, in the range of 83 %-89 % for 1 % extract dilution, and were non-hemolytic, with a hemolysis percentage below 1 %. (c) 2025 Published by Elsevier Ltd on behalf of The editorial office of Journal of Materials Science & Technology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
引用
收藏
页码:198 / 214
页数:17
相关论文
共 82 条
[1]   Biodegradable Metals [J].
Aghion, Eli .
METALS, 2018, 8 (10)
[2]   Materials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent [J].
Alexy, Ryan D. ;
Levi, Daniel S. .
BIOMED RESEARCH INTERNATIONAL, 2013, 2013
[3]   Correlations between the calculated stacking fault energy and the plasticity mechanisms in Fe-Mn-C alloys [J].
Allain, S ;
Chateau, JP ;
Bouaziz, O ;
Migot, S ;
Guelton, N .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2004, 387 :158-162
[4]   Development of Fe-Mg alloys with intermediate degradation kinetics as potential biodegradable bone implants [J].
Alsakkaf, Ahmed ;
Yusop, Abdul Hakim Md ;
Idris, Hasbullah ;
Hassan, Ahmed Ghazi ;
Iqbal, Nida ;
Unal, Rahmi ;
Sudin, Izman .
MATERIALS TODAY COMMUNICATIONS, 2024, 41
[5]  
[Anonymous], 2021, ASTM B212-21
[6]  
[Anonymous], 2017, ASTM F756-17
[7]  
[Anonymous], 2012, ASTM G31-12a
[8]  
[Anonymous], 2009, ISO 10993-5:2009, V10
[9]  
[Anonymous], 2004, ASTM E112
[10]  
[Anonymous], 2020, ASTM B213-20