Structural Performance and Failure Mechanisms in Bend Loading of Steel-Aerated Concrete Fire Wall Composite Panels

被引:0
作者
Weiss, Matthias [1 ]
Hu, Xinyu [1 ,2 ]
Pereira, Michael [3 ]
Zhang, Peng [1 ]
机构
[1] Deakin Univ, Inst Frontier Mat, Pigdons Rd, Geelong, Vic 3216, Australia
[2] Univ Elect Sci & Technol China, Shenzhen Inst Adv Study, Shenzhen 518000, Peoples R China
[3] Deakin Univ, Sch Engn, Pigdons Rd, Geelong, Vic 3216, Australia
关键词
fire rated; wall panel; aerated concrete; wind loading; bending; GEOPOLYMER FOAM CONCRETE; MODULAR BUILDINGS; FLY-ASH; STRENGTH;
D O I
10.3390/buildings15081338
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Modularised wall panels are increasingly used in building and construction. A new double-skin composite (DSC) wall system technology uses clinch seams to combine two roll-formed open section profiles into a hollow steel shell that is then filled with a light-weight concrete foam and can provide a fire-rated DSC solution for use in commercial and high-rise buildings. One important material parameter for the application is the panel performance in wind loading. This study presents a first fundamental analysis of the structural behaviour of the new DSC wall panel relevant to wind loading. For this, 3-point and 4-point bending tests combined with in situ camera analysis are performed and complimented with the analysis of seam strength and the concrete material parameters. The experimental results provide the first experimental evidence that the aerated concrete core material of the DSC panel only has a minor effect on the wall performance in bending. Most of the bending loads are absorbed by the tensile and compressive deformation of the steel outer shell and the shear deformation near the clinch seam. In this way, failure at maximum load is not initiated by concrete cracking but by steel sheet buckling or a mixed failure mode that combines steel buckling and seam opening.
引用
收藏
页数:23
相关论文
共 56 条
[1]   Properties and applications of foamed concrete; a review [J].
Amran, Y. H. Mugahed ;
Farzadnia, Nima ;
Ali, A. A. Abang .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 101 :990-1005
[2]  
Andrade P., 2014, P 7 EUR C STEEL COMP
[3]  
[Anonymous], 2022, Standard Test Methods for Tension Testing of Metallic Materials, DOI [10.1520/E0008E0008M-22, DOI 10.1520/E0008E0008M-22]
[4]  
[Anonymous], 2018, ASTM C39/C39M, DOI [10.1520/C0039_C0039M-21, DOI 10.1520/C0039_C0039M-21]
[5]  
[Anonymous], 2017, Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens
[6]   Flexural behaviour of concrete-filled double skin aluminium alloy tubes [J].
Bin Ali, Shafayat ;
Kamaris, George S. ;
Gkantou, Michaela .
ENGINEERING STRUCTURES, 2022, 272
[7]   Equivalent modelling strategy for a clinched joint using a simple calibration method [J].
Breda, Andreas ;
Coppieters, Sam ;
Debruyne, Dimitri .
THIN-WALLED STRUCTURES, 2017, 113 :1-12
[8]   Mechanical behaviour of composite sandwich panels with foamed concrete core reinforced with natural fibre in four-point bending [J].
Castillo-Lara, J. F. ;
Flores-Johnson, E. A. ;
Valadez-Gonzalez, A. ;
Herrera-Franco, P. J. ;
Carrillo, J. G. ;
Gonzalez-Chi, P., I ;
Agaliotis, E. ;
Li, Q. M. .
THIN-WALLED STRUCTURES, 2021, 169
[9]   Mechanical Properties of Natural Fiber Reinforced Foamed Concrete [J].
Castillo-Lara, Joaquin F. ;
Flores-Johnson, Emmanuel A. ;
Valadez-Gonzalez, Alex ;
Herrera-Franco, Pedro J. ;
Carrillo, Jose G. ;
Gonzalez-Chi, P., I ;
Li, Q. M. .
MATERIALS, 2020, 13 (14)
[10]   Optimization of Cellular Concrete Microstructure for Improved Impact Resistance [J].
Clark, Jamie, V ;
Lange, David A. .
TRANSPORTATION RESEARCH RECORD, 2021, 2675 (11) :237-246