Ready-to-Use OECT Biosensor toward Rapid and Real-Time Protein Detection in Complex Biological Environments

被引:0
作者
Zhang, Shouyan [1 ,2 ,3 ]
Xia, Chunyang [1 ,2 ,3 ]
Wang, Jun [1 ,2 ,3 ]
Chen, Shixiong [1 ,2 ,3 ]
Wang, Yixuan [1 ,2 ,3 ]
Zhang, Shuhua [1 ,2 ,3 ]
Geng, Zhi [1 ,2 ,3 ]
Tang, Ke [1 ]
Erdem, Arzum [4 ]
Zhu, Bo [1 ,2 ,3 ]
机构
[1] Shanghai Univ, Sch Mat Sci & Engn, Shanghai 200444, Peoples R China
[2] Minist Educ, Joint Int Res Lab Biomat & Biotechnol Organ Repair, Shanghai 200444, Peoples R China
[3] Shanghai Engn Res Ctr Organ Repair, Shanghai 200444, Peoples R China
[4] Ege Univ, Dept Analyt Chem, Fac Pharm, TR-35100 Izmir, Turkiye
来源
ACS SENSORS | 2025年
基金
中国国家自然科学基金;
关键词
organic electrochemical transistor; poly(3,4-ethylenedioxythiophene); biosensor; antifouling; polyphosphorylcholine; C-reactive protein; C-REACTIVE PROTEIN; BLOCKING; BOVINE; PHOSPHORYLCHOLINE; ANTIBODIES; BINDING; ELISA;
D O I
10.1021/acssensors.4c03072
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Organic electrochemical transistor (OECT) sensors are a promising approach for point-of-care testing (POCT) thanks to their high sensitivity and ability to operate in an aqueous environment. However, OECTs suffer from biological fouling at the gate and channel interfaces when exposed to complex biological samples. These nonspecific interactions can often obscure the weak signal from the trace biomarker, compromising the accuracy and sensitivity of measurements and even leading to false detection outcomes. In this study, we developed an intrinsically antifouling OECT by modifying both the gate and channel with phosphorylcholine-functionalized poly(3,4-ethylenedioxythiophene) (PEDOT-PC). This modification notably enhances the OECT performance by leveraging the material's inherent mixed electron-ion conductivity, which increases transconductance and decreases gate voltage. Additionally, the zwitterionic nature of the device enables its ultrasensitive detection of C-reactive protein (CRP) with a limit of detection of 0.11 pg/mL, mediated by calcium ions. This exceptional sensitivity arises from the device's enhanced transconductance and ability to sense through the gate and channel interfaces simultaneously. Furthermore, the zwitterionic OECT sensor has demonstrated the fastest sample-to-result time for protein detection (<= 60 s), making it highly suitable for real-time CRP monitoring. Importantly, it provides precise real-time detection of CRP without interference from nonspecific proteins such as bovine serum albumin, fibrinogen, lysozyme, and fetal bovine serum. We envision this intrinsically antifouling OECT device offering a robust biosensing platform for the rapid and convenient detection of biomarkers in complex biological environments, providing a reliable and efficient solution for POCT diagnostics.
引用
收藏
页数:12
相关论文
共 44 条
  • [1] BSA blocking in enzyme-linked immunosorbent assays is a non-mandatory step: a perspective study on mechanism of BSA blocking in common ELISA protocols
    Ahirwar, Rajesh
    Bariar, Shilpi
    Balakrishnan, Abitha
    Nahar, Pradip
    [J]. RSC ADVANCES, 2015, 5 (121): : 100077 - 100083
  • [2] Blocking and detection chemistries affect antibody performance on reverse phase protein arrays
    Ambroz, Kristi L. H.
    Zhang, Yonghong
    Schutz-Geschwender, Amy
    Olive, D. Michael
    [J]. PROTEOMICS, 2008, 8 (12) : 2379 - 2383
  • [3] High prevalence of human anti-bovine IgG antibodies as the major cause of false positive reactions in two-site Immunoassays based on monoclonal antibodies
    Andersen, DC
    Koch, C
    Jensen, CH
    Skjodt, K
    Brandt, J
    Teisner, B
    [J]. JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2004, 25 (01) : 17 - 30
  • [4] Characterization of Ca2+ and phosphocholine interactions with C-reactive protein using a surface plasmon resonance biosensor
    Christopeit, Tony
    Gossas, Thomas
    Danielson, U. Helena
    [J]. ANALYTICAL BIOCHEMISTRY, 2009, 391 (01) : 39 - 44
  • [5] CRAIG WY, 1994, CLIN CHEM, V40, P882
  • [6] BACKGROUND STAINING IN IMMUNOBLOT ASSAYS - REDUCTION OF SIGNAL CAUSED BY CROSS-REACTIVITY WITH BLOCKING-AGENTS
    CRAIG, WY
    POULIN, SE
    COLLINS, MF
    LEDUE, TB
    RITCHIE, RF
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 158 (01) : 67 - 76
  • [7] Point-of-care (POC) SARS-CoV-2 antigen detection using functionalized aerosol jet-printed organic electrochemical transistors (OECTs)
    Fan, Jiaxin
    Parr, Sheldon
    Kang, Seongdae
    Gupta, Manisha
    [J]. NANOSCALE, 2023, 15 (11) : 5476 - 5485
  • [8] Engineered zwitterionic phosphorylcholine monolayers for elucidating multivalent binding kinetics of C-reactive protein
    Goda, Tatsuro
    Miyahara, Yuji
    [J]. ACTA BIOMATERIALIA, 2016, 40 : 46 - 53
  • [9] Rapid single-molecule detection of COVID-19 and MERS antigens via nanobody-functionalized organic electrochemical transistors
    Guo, Keying
    Wustoni, Shofarul
    Koklu, Anil
    Diaz-Galicia, Escarlet
    Moser, Maximilian
    Hama, Adel
    Alqahtani, Ahmed A.
    Ahmad, Adeel Nazir
    Alhamlan, Fatimah Saeed
    Shuaib, Muhammad
    Pain, Arnab
    McCulloch, Iain
    Arold, Stefan T.
    Grunberg, Raik
    Inal, Sahika
    [J]. NATURE BIOMEDICAL ENGINEERING, 2021, 5 (07) : 666 - 677
  • [10] Effect of electrical conditions on an impedimetric immunosensor based on a modified conducting polypyrrole
    Hafaid, Imen
    Chebil, Syrine
    Korri-Youssoufi, Hafsa
    Bessueille, Francois
    Errachid, Abdelhamid
    Sassi, Zina
    Ali, Zulfiqur
    Abdelghani, Adnane
    Jaffrezic-Renault, Nicole
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (01) : 323 - 331