Ultrasonic coded-excitation full-matrix imaging in the wavenumber domain for coated pipe welds

被引:0
作者
Chen, Mu [1 ]
Ma, Xinzhi [1 ]
Wang, Zhigang [4 ]
Xu, Xintao [1 ]
Gu, Xu [1 ]
Yang, Keji [1 ]
Mei, Deqing [3 ]
Chen, Jian [1 ]
Jin, Haoran [1 ,2 ]
机构
[1] Zhejiang Univ, Sch Mech Engn, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310058, Peoples R China
[2] Zhejiang Univ, Sch Mech Engn, Zhejiang Key Lab Adv Equipment Mfg & Measurement T, Hangzhou 310058, Peoples R China
[3] Zhejiang Univ, Ocean Coll, Zhoushan 316022, Peoples R China
[4] PipeChina Xuzhou Pipeline Inspect Co Ltd, Xuzhou 221000, Peoples R China
关键词
Coating layer; Coded excitation; Plane wave source synthesis; Full-matrix imaging; Wavenumber domain; MEDICAL ULTRASOUND; PULSE-COMPRESSION; OPTIMIZATION; MIGRATION; SIGNALS; DESIGN; ARRAYS; TFM;
D O I
10.1016/j.ymssp.2025.112647
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Welds in long-distance pipelines are susceptible to defects due to stress concentration. However, the protective coating layers outside the pipe welds hinder ultrasound penetration. As a result, current ultrasonic nondestructive testing methods require removing the protective layer before detection, which is inefficient and labor-intensive. To address this challenge, a full-matrix ultrasonic imaging method is proposed, employing coded excitation and multi-mode wavenumber-domain image reconstruction. Nonlinear frequency modulation (NLFM) is combined with the Golay pair as the coded ultrasonic excitation sequences to achieve better penetration and side lobe suppression. The multi-mode wavenumber-domain image reconstruction method solves the complex wave propagation and image migration problems for welds covered with protective layers. Experimental results demonstrate that the proposed method can detect pipe weld defects in the presence of an approximately 2.6 mm three-layer polyethylene (3LPE) coating. Various common coated pipe weld defects can be detected with an average image signal-to-noise ratio of 20.8 dB. A frame rate of 4 Hz is achieved for one imaging mode.
引用
收藏
页数:18
相关论文
共 46 条
  • [1] Alobaidi W.M., 2015, Am. J. Oper. Res., V5, P274, DOI [10.4236/ajor.2015.54021, DOI 10.4236/AJOR.2015.54021, 10.4236/AJOR.2015.54021]
  • [2] INVESTIGATION OF NON-LINEAR CHIRP CODING FOR IMPROVED SECOND HARMONIC PULSE COMPRESSION
    Arif, Muhammad
    Ali, Muhammad Asim
    Shaikh, Muhammad Mujtaba
    Freear, Steven
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (08) : 1690 - 1702
  • [3] Parameter optimization of pulse compression in ultrasound imaging systems with coded excitation
    Behar, V
    Adam, D
    [J]. ULTRASONICS, 2004, 42 (10) : 1101 - 1109
  • [4] Benane YM, 2018, EUR SIGNAL PR CONF, P81, DOI 10.23919/EUSIPCO.2018.8553055
  • [5] A Model for Multiview Ultrasonic Array Inspection of Small Two-Dimensional Defects
    Budyn, Nicolas
    Bevan, Rhodri L. T.
    Zhang, Jie
    Croxford, Anthony J.
    Wilcox, Paul D.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (06) : 1129 - 1139
  • [6] Byrnes T, 2017, WOODHEAD PUBL SER EN, P563, DOI 10.1016/B978-0-08-101105-8.00024-3
  • [7] Ultrasonic crack evaluation by phase coherence processing and TFM and its application to online monitoring in fatigue tests
    Camacho, J.
    Atehortua, D.
    Cruza, J. F.
    Brizuela, J.
    Ealo, J.
    [J]. NDT & E INTERNATIONAL, 2018, 93 : 164 - 174
  • [8] Phase Coherence Imaging
    Camacho, Jorge
    Parrilla, Montserrat
    Fritsch, Carlos
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (05) : 958 - 974
  • [9] Full-Matrix Imaging in Fourier Domain towards Ultrasonic Inspection with Wide-Angle Oblique Incidence for Welded Structures
    Chen, Mu
    Xu, Xintao
    Yang, Keji
    Wu, Haiteng
    [J]. SENSORS, 2024, 24 (03)
  • [10] Coded excitation for diagnostic ultrasound: A system developer's perspective
    Chiao, RY
    Hao, XH
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (02) : 160 - 170