摘要
Biological wastewater treatment plants could serve as an important alternative to renewable biological nitrogen mines, which are locally available and have a low carbon footprint. Recent progress in Fenton processes has revealed their potential use for sludge treatment to decrease organic contamination and pathogens. The aim of this study was to determine the optimal concentrations of metal catalyst Fe(II) and hydrogen peroxide H2O2 for activated sludge (AS) disinfection using the Fenton process at near-neutral pH, alone and in combination with thermal treatment and UV radiation. The efficiency of the 48 h treatment was evaluated by log reduction, fluorescein diacetate (FDA) hydrolysis activity, concentration of pharmaceuticals, changes in antimicrobial resistance, and ecotoxicity. Using the desirability function approach, a combination of 239 mM H2O2 and 8.6 mM Fe(II) was found to be optimal in frames of the chosen concentrations of reagents. The FDA hydrolysis activity correlated with log reduction at 287 mM H2O2 and different Fe(II) concentrations. Sludge treatment resulted in the removal of ciprofloxacin by 65.5%. The sets with the highest log reduction, i.e., additionally treated by heating and UV, were accompanied by increasing ecotoxic effects on crustaceans, Thamnocephalus platyurus. The Fenton process shows prospective ways on sludge stabilization for its application as a fertilizer.
引用
收藏
页数:20
相关论文
共 66 条
[11]   Legislation for the Reuse of Biosolids on Agricultural Land in Europe: Overview [J].
Collivignarelli, Maria Cristina ;
Abba, Alessandro ;
Frattarola, Andrea ;
Miino, Marco Carnevale ;
Padovani, Sergio ;
Katsoyiannis, Ioannis ;
Torretta, Vincenzo .
SUSTAINABILITY, 2019, 11 (21)
[12]  
DERRINGER G, 1980, J QUAL TECHNOL, V12, P214, DOI 10.1080/00224065.1980.11980968
[13]   Evaluation of acute ecotoxicity removal from industrial wastewater using a battery of rapid bioassays [J].
Dries, Jan ;
Daens, Dominique ;
Geuens, Luc ;
Blust, Ronny .
WATER SCIENCE AND TECHNOLOGY, 2014, 70 (12) :2056-2061
[14]  
European Union, 2018, Off. J. Eur. Union L, V150, P109
[15]   Challenges of soil erosion and sludge management for sustainable development in Indonesia [J].
Fulazzaky, Mohamad Ali ;
Gany, Abdul Hafied Abdul .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2009, 90 (08) :2387-2392
[16]   Enzyme activities under anaerobic and aerobic conditions inactivated sludge sequencing batch reactor [J].
Goel, R ;
Mino, T ;
Satoh, H ;
Matsuo, T .
WATER RESEARCH, 1998, 32 (07) :2081-2088
[17]   UV Disinfection Systems for Wastewater Treatment: Emphasis on Reactivation of Microorganisms [J].
Gonzalez, Yenifer ;
Gomez, Gloria ;
Moeller-Chavez, Gabriela E. ;
Vidal, Gladys .
SUSTAINABILITY, 2023, 15 (14)
[18]   Microbial extracellular enzyme activity affects performance in a full-scale modified activated sludge process [J].
Hassard, Francis ;
Biddle, Jeremy ;
Harnett, Richard ;
Stephenson, Tom .
SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 625 :1527-1534
[19]   Different responses of gram-negative and gram-positive bacteria to photocatalytic disinfection using solar-light-driven magnetic TiO2-based material, and disinfection of real sewage [J].
He, Juhua ;
Zheng, Zexiao ;
Lo, Irene M. C. .
WATER RESEARCH, 2021, 207
[20]   Simultaneous removal of antibiotics and antibiotic resistance genes from pharmaceutical wastewater using the combinations of up-flow anaerobic sludge bed, anoxic-oxic tank, and advanced oxidation technologies [J].
Hou, Jie ;
Chen, Zeyou ;
Gao, Ju ;
Xie, Yonglei ;
Li, Linyun ;
Qin, Songyan ;
Wang, Qing ;
Mao, Daqing ;
Luo, Yi .
WATER RESEARCH, 2019, 159 :511-520