Evaluation of treatment options for atrophic mandible under trauma forces: a 3D finite element analysis treatment options for atrophic mandible under trauma forces

被引:0
|
作者
İpek Dilara Baş [1 ]
Emre Tosun [1 ]
Ilgın Ari [1 ]
Gülin Acar [1 ]
机构
[1] Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Hacettepe University, Fakülteler Neighborhood, 1 th floor, Altındağ, Ankara
关键词
Atrophic mandibula; Finite element analysis; Subperiosteal implants; Trauma;
D O I
10.1186/s12903-025-06047-6
中图分类号
学科分类号
摘要
Objective: This study aimed to assess the stress distributions at different treatment options in edentulous and severely atrophic mandibula under trauma forces. Material and method: In this study, four different treatment methods were applied to a severely atrophic edentulous mandibular model. In Model 1, inferior alveolar nerve lateralization was performed, followed by the placement of six implants. Model 2 utilized the all-on-four approach with implants placed. Model 3 used subperiosteal implants made of PEEK, while Model 4 used titanium subperiosteal implants. Each subperiosteal implant model included 14 osteosynthesis screws positioned in key areas of the mandible. 2000 Newton trauma force was applied anterior side of the mandibula. The maximum principal stress (Pmax), minimum principal stress (Pmin), and Von Mises (VMs) stress values are measured as MPa. Results: In this study, Model 4 showed the highest Pmax in the symphysis region, while the other models had similar values. The mandibular condyle exhibited the highest Pmax in Model 1 and the lowest in Model 2. The Pmin values were comparable across all models in the symphysis region. Regarding VMs stress values, balanced stress was observed in the metal frameworks of all models. Model 3 had the most balanced and lowest VMs stress in abutments and abutment screws, while Model 4 had the highest. Conclusion: This FEA study found that both the all-on-4 and PEEK subperiosteal implants are more resistant under trauma forces compared to titanium subperiosteal implants and the 6-implant IANL approach. The PEEK subperiosteal implant offers a less invasive treatment option for fractured mandibles. © The Author(s) 2025.
引用
收藏
相关论文
共 40 条
  • [31] Stress analysis of a complete maxillary denture under various drop impact conditions: a 3D finite element study
    Sunbuloglu, Emin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (14) : 1543 - 1554
  • [32] Biomechanical assessment and 3D finite element analysis of the treatment of tibial fractures using minimally invasive percutaneous plates
    Hu, Xin-Jia
    Wang, Hua
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (02) : 1692 - 1698
  • [33] Effect of Implant Diameter and Bruxism on Biomechanical Performance in Maxillary All-on-4 Treatment: A 3D Finite Element Analysis
    Sezer, Taygun
    Kilic, Kerem
    Esim, Emir
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 709 - 721
  • [34] Modelling bearing failure in countersunk composite joints under quasi-static loading using 3D explicit finite element analysis
    Egan, B.
    McCarthy, M. A.
    Frizzell, R. M.
    Gray, P. J.
    McCarthy, C. T.
    COMPOSITE STRUCTURES, 2014, 108 : 963 - 977
  • [35] Mechanical resistance of a mandibular first molar under the influence of different endodontic access cavity design: a 3D finite element analysis study
    Arican, Burcin
    Gundogar, Mustafa
    Uslu, Gulsah
    Ozyurek, Taha
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025,
  • [36] Biomechanics of internal connection in mandibular implant-supported prosthesis under effect of loadings and number of implants: A 3D finite element analysis
    Dayrell, Andreza Costa
    Pimenta de Araujo, Cintia Tereza
    Rocha, Ricardo Lopes
    Isolan, Cristina Pereira
    Noritomi, Pedro Yoshito
    Mesquita, Marcelo Ferraz
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 148
  • [37] 3D Finite element analysis of the geosynthetic reinforced soil-integrated bridge system (GRS-IBS) under different loading conditions
    Abu-Farsakh, Murad
    Ardah, Allam
    Voyiadjis, George
    TRANSPORTATION GEOTECHNICS, 2018, 15 : 70 - 83
  • [38] Development of Femoral Head Interior Supporting Device and 3D Finite Element Analysis of its Application in the Treatment of Femoral Head Avascular Necrosis
    Xiao, Dongmin
    Ye, Ming
    Li, Xinfa
    Yang, Lifeng
    MEDICAL SCIENCE MONITOR, 2015, 21 : 1520 - 1526
  • [39] Non-linear 3D finite element analysis of precast reinforced concrete Beam-Column joint under monotonic static load
    Qasem, Maged
    Hasan, Mousa
    Muhamad, Rahimah
    Mutafi, Ayad
    MATERIALS TODAY-PROCEEDINGS, 2022, 65 : 746 - 757
  • [40] Effect of implant-abutment connections with peri-implant bone defect models under removal torque force: A 3D finite element analysis
    Corekci, Ahu Uraz
    Isler, Sila Cagri
    Sengul, Janset
    Guler, Berceste
    Ozdemir, Yucel
    Ozbay, Deniz
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2023, 14 (04): : 358 - 364