Myocardial perfusion SPECT radiomic features reproducibility assessment: Impact of image reconstruction and harmonization

被引:3
作者
Gharibi, Omid [1 ,2 ,3 ]
Hajianfar, Ghasem [4 ]
Sabouri, Maziar [1 ,2 ]
Mohebi, Mobin [5 ]
Bagheri, Soroush [6 ]
Arian, Fatemeh [3 ]
Yasemi, Mohammad Javad [7 ]
Rajabi, Ahmad Bitarafan [8 ,9 ]
Rahmim, Arman [1 ,2 ,10 ]
Zaidi, Habib [4 ,11 ,12 ,13 ]
Shiri, Isaac [4 ,14 ]
机构
[1] Univ British Columbia, Dept Phys & Astron, Vancouver, BC, Canada
[2] BC Canc Res Inst, Dept Integrat Oncol, Vancouver, BC, Canada
[3] Iran Univ Med Sci, Sch Med, Dept Med Phys, Tehran, Iran
[4] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[5] Tarbiat Modares Univ, Dept Biomed Engn, Tehran, Iran
[6] Kashan Univ Med Sci, Dept Med Phys, Kashan, Iran
[7] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[8] Iran Univ Med Sci, Echocardiog Res Ctr, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[9] Iran Univ Med Sci, Cardiovasc Intervent Res Ctr, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[10] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[11] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[12] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[13] Obuda Univ, Univ Res & Innovat Ctr, Budapest, Hungary
[14] Univ Bern, Bern Univ Hosp, Inselspital, Dept Cardiol, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
harmonization; MPI-SPECT; radiomics; reproducibility; CLINICAL-VALUE; QUANTIFICATION; SEGMENTATION; DIAGNOSIS; SETTINGS; SYSTEM;
D O I
10.1002/mp.17490
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Coronary artery disease (CAD) has one of the highest mortality rates in humans worldwide. Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) provides clinicians with myocardial metabolic information non-invasively. However, there are some limitations to interpreting SPECT images performed by physicians or automatic quantitative approaches. Radiomics analyzes images objectively by extracting quantitative features and can potentially reveal biological characteristics that the human eye cannot detect. However, the reproducibility and repeatability of some radiomic features can be highly susceptible to segmentation and imaging conditions. Purpose We aimed to assess the reproducibility of radiomic features extracted from uncorrected MPI-SPECT images reconstructed with 15 different settings before and after ComBat harmonization, along with evaluating the effectiveness of ComBat in realigning feature distributions. Materials and methods A total of 200 patients (50% normal and 50% abnormal) including rest and stress (without attenuation and scatter corrections) MPI-SPECT images were included. Images were reconstructed using 15 combinations of filter cut-off frequencies, filter orders, filter types, reconstruction algorithms, number of iterations and subsets resulting in 6000 images. Image segmentation was performed on the left ventricle in the first reconstruction for each patient and applied to 14 others. A total of 93 radiomic features were extracted from the segmented area, and ComBat was used to harmonize them. The intraclass correlation coefficient (ICC) and overall concordance correlation coefficient (OCCC) tests were performed before and after ComBat to examine the impact of each parameter on feature robustness and to assess harmonization efficiency. The ANOVA and the Kruskal-Wallis tests were performed to evaluate the effectiveness of ComBat in correcting feature distributions. In addition, the Student's t-test, Wilcoxon rank-sum, and signed-rank tests were implemented to assess the significance level of the impacts made by each parameter of different batches and patient groups (normal vs. abnormal) on radiomic features. Results Before applying ComBat, the majority of features (ICC: 82, OCCC: 61) achieved high reproducibility (ICC/OCCC >= 0.900) under every batch except Reconstruction. The largest and smallest number of poor features (ICC/OCCC < 0.500) were obtained by IterationSubset and Order batches, respectively. The most reliable features were from the first-order (FO) and gray-level co-occurrence matrix (GLCM) families. Following harmonization, the minimum number of robust features increased (ICC: 84, OCCC: 78). Applying ComBat showed that Order and Reconstruction were the least and the most responsive batches, respectively. The most robust families, in a descending order, were found to be FO, neighborhood gray-tone difference matrix (NGTDM), GLCM, gray-level run length matrix (GLRLM), gray-level size zone matrix (GLSZM), and gray-level dependence matrix (GLDM) under Cut-off, Filter, and Order batches. The Wilcoxon rank-sum test showed that the number of robust features significantly differed under most batches in the Normal and Abnormal groups. Conclusion The majority of radiomic features show high levels of robustness across different OSEM reconstruction parameters in uncorrected MPI-SPECT. ComBat is effective in realigning feature distributions and enhancing radiomic features reproducibility.
引用
收藏
页码:965 / 977
页数:13
相关论文
共 74 条
[41]   Post-revascularization Ejection Fraction Prediction for Patients Undergoing Percutaneous Coronary Intervention Based on Myocardial Perfusion SPECT Imaging Radiomics: a Preliminary Machine Learning Study [J].
Mohebi, Mobin ;
Amini, Mehdi ;
Alemzadeh-Ansari, Mohammad Javad ;
Alizadehasl, Azin ;
Rajabi, Ahmad Bitarafan ;
Shiri, Isaac ;
Zaidi, Habib ;
Orooji, Mahdi .
JOURNAL OF DIGITAL IMAGING, 2023, 36 (04) :1348-1363
[42]   Radiomics in PET Imaging: A Practical Guide for Newcomers [J].
Orlhac, Fanny ;
Nioche, Christophe ;
Klyuzhin, Ivan ;
Rahmim, Arman ;
Buvat, Irene .
PET CLINICS, 2021, 16 (04) :597-612
[43]   A Guide to ComBat Harmonization of Imaging Biomarkers in Multicenter Studies [J].
Orlhac, Fanny ;
Eertink, Jakoba J. ;
Cottereau, Anne-Segolene ;
Zijlstra, Josee M. ;
Thieblemont, Catherine ;
Meignan, Michel ;
Boellaard, Ronald ;
Buvat, Irene .
JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (02) :172-179
[44]   A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET [J].
Orlhac, Fanny ;
Boughdad, Sarah ;
Philippe, Cathy ;
Stalla-Bourdillon, Hugo ;
Nioche, Christophe ;
Champion, Laurence ;
Soussan, Michael ;
Frouin, Frederique ;
Frouin, Vincent ;
Buvat, Irene .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (08) :1321-1328
[45]   Methodology and application of the Kruskal-Wallis test [J].
Ostertagová, Eva ;
Ostertag, Oskar ;
Kováč, Jozef .
Applied Mechanics and Materials, 2014, 611 :115-120
[46]   A systematic review and quality of reporting checklist for repeatability and reproducibility of radiomic features [J].
Pfaehler, Elisabeth ;
Zhovannik, Ivan ;
Wei, Lise ;
Boellaard, Ronald ;
Dekker, Andre ;
El Naqa, Issam ;
Bussink, Jan ;
Gillies, Robert ;
Wee, Leonard ;
Traverso, Alberto .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 20 :69-75
[47]   ComBat Harmonization of Myocardial Radiomic Features Sensitive to Cardiac MRI Acquisition Parameters [J].
Priya, Sarv ;
Dhruba, Durjoy D. ;
Sorensen, Eldon ;
Aher, Pritish Y. ;
Narayanasamy, Sabarish ;
Nagpal, Prashant ;
Jacob, Mathews ;
Carter, Knute D. .
RADIOLOGY-CARDIOTHORACIC IMAGING, 2023, 5 (04)
[48]   Reproducibility and non-redundancy of radiomic features extracted from arterial phase CT scans in hepatocellular carcinoma patients: impact of tumor segmentation variability [J].
Qiu, Qingtao ;
Duan, Jinghao ;
Duan, Zuyun ;
Meng, Xiangjuan ;
Ma, Changsheng ;
Zhu, Jian ;
Lu, Jie ;
Liu, Tonghai ;
Yin, Yong .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (03) :453-+
[49]   Application of texture analysis to DAT SPECT imaging: Relationship to clinical assessments [J].
Rahmim, Arman ;
Salimpour, Yousef ;
Jain, Saurabh ;
Blinder, Stephan A. L. ;
Klyuzhin, Ivans S. ;
Smith, Gwenn S. ;
Mari, Zoltan ;
Sossi, Vesna .
NEUROIMAGE-CLINICAL, 2016, 12 :E1-E9
[50]  
RaisiEstabragh Z., 2020, FRONT CARDIOVASC MED, V7