Myocardial perfusion SPECT radiomic features reproducibility assessment: Impact of image reconstruction and harmonization

被引:3
作者
Gharibi, Omid [1 ,2 ,3 ]
Hajianfar, Ghasem [4 ]
Sabouri, Maziar [1 ,2 ]
Mohebi, Mobin [5 ]
Bagheri, Soroush [6 ]
Arian, Fatemeh [3 ]
Yasemi, Mohammad Javad [7 ]
Rajabi, Ahmad Bitarafan [8 ,9 ]
Rahmim, Arman [1 ,2 ,10 ]
Zaidi, Habib [4 ,11 ,12 ,13 ]
Shiri, Isaac [4 ,14 ]
机构
[1] Univ British Columbia, Dept Phys & Astron, Vancouver, BC, Canada
[2] BC Canc Res Inst, Dept Integrat Oncol, Vancouver, BC, Canada
[3] Iran Univ Med Sci, Sch Med, Dept Med Phys, Tehran, Iran
[4] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[5] Tarbiat Modares Univ, Dept Biomed Engn, Tehran, Iran
[6] Kashan Univ Med Sci, Dept Med Phys, Kashan, Iran
[7] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[8] Iran Univ Med Sci, Echocardiog Res Ctr, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[9] Iran Univ Med Sci, Cardiovasc Intervent Res Ctr, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[10] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[11] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[12] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[13] Obuda Univ, Univ Res & Innovat Ctr, Budapest, Hungary
[14] Univ Bern, Bern Univ Hosp, Inselspital, Dept Cardiol, Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
harmonization; MPI-SPECT; radiomics; reproducibility; CLINICAL-VALUE; QUANTIFICATION; SEGMENTATION; DIAGNOSIS; SETTINGS; SYSTEM;
D O I
10.1002/mp.17490
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Coronary artery disease (CAD) has one of the highest mortality rates in humans worldwide. Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) provides clinicians with myocardial metabolic information non-invasively. However, there are some limitations to interpreting SPECT images performed by physicians or automatic quantitative approaches. Radiomics analyzes images objectively by extracting quantitative features and can potentially reveal biological characteristics that the human eye cannot detect. However, the reproducibility and repeatability of some radiomic features can be highly susceptible to segmentation and imaging conditions. Purpose We aimed to assess the reproducibility of radiomic features extracted from uncorrected MPI-SPECT images reconstructed with 15 different settings before and after ComBat harmonization, along with evaluating the effectiveness of ComBat in realigning feature distributions. Materials and methods A total of 200 patients (50% normal and 50% abnormal) including rest and stress (without attenuation and scatter corrections) MPI-SPECT images were included. Images were reconstructed using 15 combinations of filter cut-off frequencies, filter orders, filter types, reconstruction algorithms, number of iterations and subsets resulting in 6000 images. Image segmentation was performed on the left ventricle in the first reconstruction for each patient and applied to 14 others. A total of 93 radiomic features were extracted from the segmented area, and ComBat was used to harmonize them. The intraclass correlation coefficient (ICC) and overall concordance correlation coefficient (OCCC) tests were performed before and after ComBat to examine the impact of each parameter on feature robustness and to assess harmonization efficiency. The ANOVA and the Kruskal-Wallis tests were performed to evaluate the effectiveness of ComBat in correcting feature distributions. In addition, the Student's t-test, Wilcoxon rank-sum, and signed-rank tests were implemented to assess the significance level of the impacts made by each parameter of different batches and patient groups (normal vs. abnormal) on radiomic features. Results Before applying ComBat, the majority of features (ICC: 82, OCCC: 61) achieved high reproducibility (ICC/OCCC >= 0.900) under every batch except Reconstruction. The largest and smallest number of poor features (ICC/OCCC < 0.500) were obtained by IterationSubset and Order batches, respectively. The most reliable features were from the first-order (FO) and gray-level co-occurrence matrix (GLCM) families. Following harmonization, the minimum number of robust features increased (ICC: 84, OCCC: 78). Applying ComBat showed that Order and Reconstruction were the least and the most responsive batches, respectively. The most robust families, in a descending order, were found to be FO, neighborhood gray-tone difference matrix (NGTDM), GLCM, gray-level run length matrix (GLRLM), gray-level size zone matrix (GLSZM), and gray-level dependence matrix (GLDM) under Cut-off, Filter, and Order batches. The Wilcoxon rank-sum test showed that the number of robust features significantly differed under most batches in the Normal and Abnormal groups. Conclusion The majority of radiomic features show high levels of robustness across different OSEM reconstruction parameters in uncorrected MPI-SPECT. ComBat is effective in realigning feature distributions and enhancing radiomic features reproducibility.
引用
收藏
页码:965 / 977
页数:13
相关论文
共 74 条
[1]  
Alexanderson E., 2016, IAEA HUM HLTH SERIES, V23, P46
[2]   Radiomics in Cardiac Computed Tomography [J].
Ayx, Isabelle ;
Froelich, Matthias F. F. ;
Baumann, Stefan ;
Papavassiliu, Theano ;
Schoenberg, Stefan O. O. .
DIAGNOSTICS, 2023, 13 (02)
[3]   Overall concordance correlation coefficient for evaluating agreement among multiple observers [J].
Barnhart, HX ;
Haber, M ;
Song, JL .
BIOMETRICS, 2002, 58 (04) :1020-1027
[4]   CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING [J].
BENJAMINI, Y ;
HOCHBERG, Y .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) :289-300
[5]   Quality of science and reporting for radiomics in cardiac magnetic resonance imaging studies: a systematic review [J].
Chang, Suyon ;
Han, Kyunghwa ;
Suh, Young Joo ;
Choi, Byoung Wook .
EUROPEAN RADIOLOGY, 2022, 32 (07) :4361-4373
[6]  
Core Team R, 2010, R: A Language and Environment for Statistical Computing
[7]   Harmonization strategies for multicenter radiomics investigations [J].
Da-Ano, R. ;
Visvikis, D. ;
Hatt, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24)
[8]   Performance comparison of modified ComBat for harmonization of radiomic features for multicenter studies [J].
Da-ano, R. ;
Masson, I ;
Lucia, F. ;
Dore, M. ;
Robin, P. ;
Alfieri, J. ;
Rousseau, C. ;
Mervoyer, A. ;
Reinhold, C. ;
Castelli, J. ;
De Crevoisier, R. ;
Ramee, J. F. ;
Pradier, O. ;
Schick, U. ;
Visvikis, D. ;
Hatt, M. .
SCIENTIFIC REPORTS, 2020, 10 (01)
[9]   Cardiac SPECT radiomic features repeatability and reproducibility: A multi-scanner phantom study [J].
Edalat-Javid, Mohammad ;
Shiri, Isaac ;
Hajianfar, Ghasem ;
Abdollahi, Hamid ;
Arabi, Hossein ;
Oveisi, Niki ;
Javadian, Mohammad ;
Zafarghandi, Mojtaba Shamsaei ;
Malek, Hadi ;
Bitarafan-Rajabi, Ahmad ;
Oveisi, Mehrdad ;
Zaidi, Habib .
JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) :2730-2744
[10]   Reproducibility of lung cancer radiomics features extracted from data-driven respiratory gating and free-breathing flow imaging in [18F]-FDG PET/CT [J].
Faist, Daphne ;
Jreige, Mario ;
Oreiller, Valentin ;
Lalonde, Marie Nicod ;
Schaefer, Niklaus ;
Depeursinge, Adrien ;
Prior, John O. .
EUROPEAN JOURNAL OF HYBRID IMAGING, 2022, 6 (01)