The LET enhancement of energy-specific collimation in pencil beam scanning proton therapy

被引:0
|
作者
Smith, Blake R. [1 ]
Hyer, Daniel E. [1 ]
机构
[1] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2025年 / 26卷 / 01期
基金
美国国家卫生研究院;
关键词
collimation; LET; PBS; protons; RBE; RELATIVE BIOLOGICAL EFFECTIVENESS; MONTE-CARLO-SIMULATION; DYNAMIC COLLIMATION; MODEL; HEAD;
D O I
10.1002/acm2.14477
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo computationally characterize the LET distribution during dynamic collimation in PBS and quantify its impact on the resultant dose distribution.MethodsMonte Carlo simulations using Geant4 were used to model the production of low-energy proton scatter produced in the collimating components of a novel PBS collimator. Custom spectral tallies were created to quantify the energy, track- and dose-averaged LET resulting from individual beamlet and composite fields simulated from a model of the IBA dedicated nozzle system. The composite dose distributions were optimized to achieve a uniform physical dose coverage of a cubical and pyramidal target, and the resulting dose-average LET distributions were calculated for uncollimated and collimated PBS deliveries and used to generate RBE-weighted dose distributions.ResultsFor collimated beamlets, the scattered proton energy fluence is strongly dependent on collimator position relative to the central axis of the beamlet. When delivering a uniform profile, the distribution of dose-average LET was nearly identical within the target and increased between 1 and 2keV/mu m$2 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$ within 10 mm surrounding the target. Dynamic collimation resulted in larger dose-average LET changes: increasing the dose-average LET between 1 and 3keV/mu m$3 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$ within 10 mm of a pyramidal target while reducing the dose-average LET outside this margin by as much as 10keV/mu m$10 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$. Biological dose distributions are improved with energy-specific collimation in reducing the lateral penumbra.ConclusionThe presence of energy-specific collimation in PBS can lead to dose-average LET changes relative to an uncollimated delivery. In some clinical situations, the placement and application of energy-specific collimation may require additional planning considerations based on its reduction to the lateral penumbra and increase in high-dose conformity. Future applications may embody these unique dosimetric characteristics to redirect high-LET portions of a collimated proton beamlet from healthy tissues while enhancing the dose-average LET distribution within target.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A study of lateral fall-off (penumbra) optimisation for pencil beam scanning (PBS) proton therapy
    Winterhalter, C.
    Lomax, A.
    Oxley, D.
    Weber, D. C.
    Safai, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
  • [42] A Monte Carlo study of different LET definitions and calculation parameters for proton beam therapy
    Smith, Edward A. K.
    Winterhalter, Carla
    Underwood, Tracy S. A.
    Aitkenhead, Adam H.
    Richardson, Jenny C.
    Merchant, Michael J.
    Kirkby, Norman F.
    Kirby, Karen J.
    Mackay, Ranald, I
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (01)
  • [43] Automation of pencil beam scanning proton treatment planning for intracranial tumours
    Placidi, Lorenzo
    Righetto, Roberto
    Vecchi, Claudio
    Zara, Stefania
    Alparone, Alessandro
    Moretti, Roberto
    Amelio, Dante
    Scartoni, Daniele
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 105
  • [44] Spot decomposition in a novel pencil beam scanning proton Computed Tomography
    Zhou, J.
    Li, X.
    Kabolizadeh, P.
    Yang, X.
    Yan, D.
    Stevens, C.
    Liu, T.
    Ding, X.
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [45] Double scattering and pencil beam scanning Monte Carlo workflows for proton therapy retrospective studies on radiation-induced toxicities
    Leite, A. M. M.
    Bonfrate, A.
    Da Fonseca, A.
    Lansonneur, P.
    Alapetite, C.
    Mammar, H.
    De Marzi, L.
    CANCER RADIOTHERAPIE, 2023, 27 (04): : 319 - 327
  • [46] Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance
    Lin, Liyong
    Kang, Minglei
    Solberg, Timothy D.
    Mertens, Thierry
    Baumer, Christian
    Ainsley, Christopher G.
    McDonough, James E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 270 - 276
  • [47] A Monte Carlo study for the calculation of the average linear energy transfer (LET) distributions for a clinical proton beam line and a radiobiological carbon ion beam line
    Romano, F.
    Cirrone, G. A. P.
    Cuttone, G.
    Di Rosa, F.
    Mazzaglia, S. E.
    Petrovic, I.
    Fira, A. Ristic
    Varisano, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (12) : 2863 - 2882
  • [48] Pencil beam scanning proton therapy vs rotational arc radiation therapy: A treatment planning comparison for postoperative oropharyngeal cancer
    Apinorasethkul, Ontida
    Kirk, Maura
    Teo, Kevin
    Swisher-McClure, Samuel
    Lukens, John N.
    Lin, Alexander
    MEDICAL DOSIMETRY, 2017, 42 (01) : 7 - 11
  • [49] A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: Proof of concept
    Hyer, Daniel E.
    Hill, Patrick M.
    Wang, Dongxu
    Smith, Blake R.
    Flynn, Ryan T.
    MEDICAL PHYSICS, 2014, 41 (09)
  • [50] Development and Validation of an Optimal GATE Model for Pencil Beam Scanning (PBS) Proton Beam Delivery
    Asadi, Ali
    Varnaseri, Seraj
    Moshiri, Shirin
    Akhavanallaf, Azadeh
    Arabi, Hossein
    Zaidi, Habib
    2023 30TH NATIONAL AND 8TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2023, : 471 - 474