The LET enhancement of energy-specific collimation in pencil beam scanning proton therapy

被引:0
|
作者
Smith, Blake R. [1 ]
Hyer, Daniel E. [1 ]
机构
[1] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2025年 / 26卷 / 01期
基金
美国国家卫生研究院;
关键词
collimation; LET; PBS; protons; RBE; RELATIVE BIOLOGICAL EFFECTIVENESS; MONTE-CARLO-SIMULATION; DYNAMIC COLLIMATION; MODEL; HEAD;
D O I
10.1002/acm2.14477
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo computationally characterize the LET distribution during dynamic collimation in PBS and quantify its impact on the resultant dose distribution.MethodsMonte Carlo simulations using Geant4 were used to model the production of low-energy proton scatter produced in the collimating components of a novel PBS collimator. Custom spectral tallies were created to quantify the energy, track- and dose-averaged LET resulting from individual beamlet and composite fields simulated from a model of the IBA dedicated nozzle system. The composite dose distributions were optimized to achieve a uniform physical dose coverage of a cubical and pyramidal target, and the resulting dose-average LET distributions were calculated for uncollimated and collimated PBS deliveries and used to generate RBE-weighted dose distributions.ResultsFor collimated beamlets, the scattered proton energy fluence is strongly dependent on collimator position relative to the central axis of the beamlet. When delivering a uniform profile, the distribution of dose-average LET was nearly identical within the target and increased between 1 and 2keV/mu m$2 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$ within 10 mm surrounding the target. Dynamic collimation resulted in larger dose-average LET changes: increasing the dose-average LET between 1 and 3keV/mu m$3 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$ within 10 mm of a pyramidal target while reducing the dose-average LET outside this margin by as much as 10keV/mu m$10 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$. Biological dose distributions are improved with energy-specific collimation in reducing the lateral penumbra.ConclusionThe presence of energy-specific collimation in PBS can lead to dose-average LET changes relative to an uncollimated delivery. In some clinical situations, the placement and application of energy-specific collimation may require additional planning considerations based on its reduction to the lateral penumbra and increase in high-dose conformity. Future applications may embody these unique dosimetric characteristics to redirect high-LET portions of a collimated proton beamlet from healthy tissues while enhancing the dose-average LET distribution within target.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Characterization of proton pencil beam scanning and passive beam using a high spatial resolution solid-state microdosimeter
    Tran, Linh T.
    Chartier, Lachlan
    Bolst, David
    Pogossov, Alex
    Guatelli, Susanna
    Petasecca, Marco
    Lerch, Michael L. F.
    Prokopovich, Dale A.
    Reinhard, Mark I.
    Clasie, Benjamin
    Depauw, Nicolas
    Kooy, Hanne
    Flanz, Jacob B.
    McNamara, Aimee
    Paganetti, Harald
    Beltran, Chris
    Furutani, Keith
    Perevertaylo, Vladimir L.
    Jackson, Michael
    Rosenfeld, Anatoly B.
    MEDICAL PHYSICS, 2017, 44 (11) : 6085 - 6095
  • [32] The Effects of a Dynamic Collimation System On Proton Pencil Beams to Improve Lateral Tissue Sparing in Spot Scanned Proton Therapy
    Hill, P.
    Wang, D.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2014, 41 (06) : 298 - 298
  • [33] Validation of automated complex head and neck treatment planning with pencil beam scanning proton therapy
    Hedrick, Samantha Grace
    Petro, Scott
    Ward, Alex
    Morris, Bart
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02):
  • [34] Commissioning of the world's first compact pencil-beam scanning proton therapy system
    Pidikiti, Rajesh
    Patel, Bijal C.
    Maynard, Matthew R.
    Dugas, Joseph P.
    Syh, Joseph
    Sahoo, Narayan
    Wu, Hsinshun Terry
    Rosen, Lane R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 94 - 105
  • [35] Absolute dosimetry for FLASH proton pencil beam scanning radiotherapy
    Lourenco, Ana
    Subiel, Anna
    Lee, Nigel
    Flynn, Sam
    Cotterill, John
    Shipley, David
    Romano, Francesco
    Speth, Joe
    Lee, Eunsin
    Zhang, Yongbin
    Xiao, Zhiyan
    Mascia, Anthony
    Amos, Richard A.
    Palmans, Hugo
    Thomas, Russell
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [36] Correlation of LET With MRI Changes in Brain and Potential Implications for Normal Tissue Complication Probability for Patients With Meningioma Treated With Pencil Beam Scanning Proton Therapy
    Bertolet, Alejandro
    Abolfath, Ramin
    Carlson, David J.
    Lustig, Robert A.
    Hill-Kayser, Christine
    Alonso-Basanta, Michelle
    Carabe, Alejandro
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 112 (01): : 237 - 246
  • [37] Plan quality effects of maximum monitor unit constraints in pencil beam scanning proton therapy for central nervous system and skull base tumors
    Rao, Avani Dholakia
    Sun, Kai
    Zhu, Mingyao
    Mossahebi, Sina
    Sabouri, Pouya
    Houser, Thomas
    Jatczak, Jenna
    Zakhary, Mark
    Regine, William F.
    Miller, Robert C.
    Bentzen, Soren
    Mishra, Mark, V
    RADIOTHERAPY AND ONCOLOGY, 2021, 160 : 18 - 24
  • [38] Assessment of pencil beam scanning proton therapy beam delivery accuracy through machine learning and log file analysis
    Ranjith, C. P.
    Krishnan, Mayakannan
    Raveendran, Vysakh
    Chaudhari, Lalit
    Laskar, Siddhartha
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 127
  • [39] Secondary neutron dose contribution from pencil beam scanning, scattered and spatially fractionated proton therapy
    Leite, A. M. M.
    Ronga, M. G.
    Giorgi, M.
    Ristic, Y.
    Perrot, Y.
    Trompier, F.
    Prezado, Y.
    Crehange, G.
    De Marzi, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (22)
  • [40] Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy
    Liu, Chunbo
    Ho, Meng Wei
    Park, Jiyeon
    Hsi, Wen Chien
    Liang, Xiaoying
    Li, Zuofeng
    Song, Yuntao
    Feng, Hansheng
    Zhang, Yawei
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20