The LET enhancement of energy-specific collimation in pencil beam scanning proton therapy

被引:0
|
作者
Smith, Blake R. [1 ]
Hyer, Daniel E. [1 ]
机构
[1] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2025年 / 26卷 / 01期
基金
美国国家卫生研究院;
关键词
collimation; LET; PBS; protons; RBE; RELATIVE BIOLOGICAL EFFECTIVENESS; MONTE-CARLO-SIMULATION; DYNAMIC COLLIMATION; MODEL; HEAD;
D O I
10.1002/acm2.14477
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo computationally characterize the LET distribution during dynamic collimation in PBS and quantify its impact on the resultant dose distribution.MethodsMonte Carlo simulations using Geant4 were used to model the production of low-energy proton scatter produced in the collimating components of a novel PBS collimator. Custom spectral tallies were created to quantify the energy, track- and dose-averaged LET resulting from individual beamlet and composite fields simulated from a model of the IBA dedicated nozzle system. The composite dose distributions were optimized to achieve a uniform physical dose coverage of a cubical and pyramidal target, and the resulting dose-average LET distributions were calculated for uncollimated and collimated PBS deliveries and used to generate RBE-weighted dose distributions.ResultsFor collimated beamlets, the scattered proton energy fluence is strongly dependent on collimator position relative to the central axis of the beamlet. When delivering a uniform profile, the distribution of dose-average LET was nearly identical within the target and increased between 1 and 2keV/mu m$2 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$ within 10 mm surrounding the target. Dynamic collimation resulted in larger dose-average LET changes: increasing the dose-average LET between 1 and 3keV/mu m$3 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$ within 10 mm of a pyramidal target while reducing the dose-average LET outside this margin by as much as 10keV/mu m$10 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$. Biological dose distributions are improved with energy-specific collimation in reducing the lateral penumbra.ConclusionThe presence of energy-specific collimation in PBS can lead to dose-average LET changes relative to an uncollimated delivery. In some clinical situations, the placement and application of energy-specific collimation may require additional planning considerations based on its reduction to the lateral penumbra and increase in high-dose conformity. Future applications may embody these unique dosimetric characteristics to redirect high-LET portions of a collimated proton beamlet from healthy tissues while enhancing the dose-average LET distribution within target.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams
    Charlwood, Frances C.
    Aitkenhead, Adam H.
    Mackay, Ranald I.
    MEDICAL PHYSICS, 2016, 43 (03) : 1462 - 1472
  • [2] Integration and dosimetric validation of a dynamic collimation system for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Gutierrez, Alonso N.
    Boland, Thibault
    Hill, Patrick M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (06)
  • [3] Contour scanning, multi-leaf collimation and the combination thereof for proton pencil beam scanning
    Winterhalter, Carla
    Meier, Gabriel
    Oxley, David
    Weber, Damien C.
    Lomax, Antony J.
    Safai, Sairos
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (01)
  • [4] Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy
    Hyer, Daniel E.
    Bennett, Laura C.
    Geoghegan, Theodore J.
    Bues, Martin
    Smith, Blake R.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2021, 8 (01) : 73 - 83
  • [5] Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy
    Smith, Blake R.
    Pankuch, Mark
    Hyer, Daniel E.
    Culberson, Wesley S.
    MEDICAL PHYSICS, 2020, 47 (10) : 5343 - 5356
  • [6] Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Rana, Suresh
    Gutierrez, Alonso N.
    Hill, Patrick M.
    MEDICAL PHYSICS, 2021, 48 (06) : 3172 - 3185
  • [7] The dosimetric enhancement of GRID profiles using an external collimator in pencil beam scanning proton therapy
    Smith, Blake R.
    Nelson, Nicholas P.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Hill, Patrick M.
    Yu, Jen
    Gutierrez, Alonso N.
    Allen, Bryan G.
    Hyer, Daniel E.
    MEDICAL PHYSICS, 2022, 49 (04) : 2684 - 2698
  • [8] Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Smith, Blake R.
    Flynn, Ryan T.
    Hill, Patrick M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02)
  • [9] Determination of surface dose in pencil beam scanning proton therapy
    Kern, A.
    Baeumer, C.
    Kroeninger, K.
    Mertens, L.
    Timmermann, B.
    Walbersloh, J.
    Wulff, J.
    MEDICAL PHYSICS, 2020, 47 (05) : 2277 - 2288
  • [10] Collimating individual beamlets in pencil beam scanning proton therapy, a dosimetric investigation
    Holmes, Jason
    Shen, Jiajian
    Patel, Samir H.
    Wong, William W.
    Foote, Robert L.
    Bues, Martin
    Liu, Wei