Simultaneous determination of serotonin, dopamine, and ascorbic acid at a glassy carbon electrode modified with chitosan-alginate hydrogel and reduced graphene oxide

被引:0
|
作者
Postolovic, Katarina S. [1 ]
Radovanovic, Milan B. [2 ]
Stanic, Zorka D. [1 ]
机构
[1] Univ Kragujevac, Fac Sci, Dept Chem, Kragujevac, Serbia
[2] Univ Belgrade, Tech Fac Bor, Bor, Serbia
关键词
Dopamine; Serotonin; Ascorbic acid; Chitosan-alginate hydrogel; Graphene oxide; Voltammetric sensor; SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; URIC-ACID; VOLTAMMETRIC DETERMINATION; POLYELECTROLYTE COMPLEXES; SENSOR; RECOGNITION; BIOSENSOR; COMPOSITES; NANOTUBES; DRUG;
D O I
10.1016/j.jelechem.2025.118992
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detection of biologically active components, such as ascorbic acid, dopamine, and serotonin, is significant from the perspective of biomedicine, particularly in the process of disease diagnosis and in the quality control of commercial pharmaceutical products. In this work, a novel electrochemical sensor was developed by modifying a glassy carbon electrode with a hydrogel composed of a polyelectrolyte complex of alginate and chitosan, along with the addition of electrochemically reduced graphene oxide. This biocompatible sensor was applied for the simultaneous determination of ascorbic acid, dopamine, and serotonin using adsorptive square wave voltammetry. The modified GCE demonstrated an excellent electrochemical response towards the target analytes, thanks to the enhanced adsorption of the analytes on the surface of the electrode, facilitated by favorable interactions between analytes and the modifiers. This approach increased the electrode's active surface area and ensured excellent electrode response. The sensor exhibited a broad linear range of the anodic current relative to analyte concentration, achieving low detection limits of 0.094 mu M, 4.18 nM and 3.23 nM for ascorbic acid, dopamine and serotonin, respectively. Additionally, the proposed sensor exhibited good stability, reproducibility of results, selectivity, as well as effectiveness, in the determination of target biological compounds in real sample matrices.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Application of graphene oxide/lanthanum-modified carbon paste electrode for the selective determination of dopamine
    Ye, Fengying
    Feng, Chenqi
    Fu, Ning
    Wu, Huihui
    Jiang, Jibo
    Han, Sheng
    APPLIED SURFACE SCIENCE, 2015, 357 : 1251 - 1259
  • [32] Solar graphene modified glassy carbon electrode for the voltammetric resolution and detection of dopamine, ascorbic acid and uric acid
    Nancy, T. E. Mary
    Anithakumary, V.
    Swamy, B. E. Kumara
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 720 : 107 - 114
  • [33] Ultrasensitive Reduced Graphene Oxide-Poly(Procion)/Gold Nanoparticles Modified Glassy Carbon Electrode for Selective and Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid
    Edris, Nusiba Mohammed Modawe Alshik
    Abdullah, Jaafar
    Kamaruzaman, Sazlinda
    Sulaiman, Yusran
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (08) : B664 - B672
  • [34] Carbon-nanotube-modified glassy carbon electrode for simultaneous determination of dopamine, ascorbic acid and uric acid: The effect of functional groups
    Bi, Huaqing
    Li, Yanhui
    Liu, Shufeng
    Guo, Peizhi
    Wei, Zhongbin
    Lv, Chunxiao
    Zhang, Jizhen
    Zhao, X. S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1132 - 1140
  • [35] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Nitrogen Doped Carbon Sphere Modified Glassy Carbon Electrode
    Ye, Fucheng
    Wen, Zubiao
    Wu, Hongfu
    Wang, Chunyan
    Qian, Yong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1136 - 1143
  • [36] Fabrication of Cetyltrimethylammonium Bromide/chitosan Modified Glassy Carbon Electrode for Simultaneous Determination of Uric Acid and Ascorbic Acid
    Zhang, Ying
    Luo, Li-Qiang
    Ding, Ya-Ping
    Li, Qiu-Xia
    Shen, Xia
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (5A) : 1061 - 1066
  • [37] Simultaneous determination of ascorbic acid, dopamine and serotonin at poly(phenosafranine) modified electrode
    Selvaraju, T
    Ramaraj, R
    ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (08) : 667 - 672
  • [38] Electrochemical determination of dopamine using a glassy carbon electrode modified with TiN-reduced graphene oxide nanocomposite
    Haldorai, Yuvaraj
    Vilian, A. T. Ezhil
    Rethinasabapathy, Muruganantham
    Huh, Yun Suk
    Han, Young-Kyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 61 - 69
  • [39] Simultaneous determination of dopamine, ascorbic acid by polyethylene oxide (PEO) covalently modified glassy carbon electrode
    Gong, Wei
    Dou, Zhi-Yu
    Liu, Ping
    Cai, Xue-Ying
    He, Xing-quan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 666 : 62 - 66
  • [40] A novel γ-aminobutyric acid monolayer modified glassy carbon electrode for simultaneous determination of dopamine, uric acid and ascorbic acid
    Zhang, L
    Lin, XQ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (04): : 591 - 594