共 20 条
Reliability of motion phase identification for long-track speed skating using inertial measurement units
被引:1
作者:

Iizuka, Tomoki
论文数: 0 引用数: 0
h-index: 0
机构:
Kurosawa Hosp, Dept Rehabil, Takasaki, Gunma, Japan
Takasaki Univ Hlth & Welf, Grad Sch Hlth Care, Dept Phys Therapy, Takasaki, Gunma, Japan Kurosawa Hosp, Dept Rehabil, Takasaki, Gunma, Japan

Tomita, Yosuke
论文数: 0 引用数: 0
h-index: 0
机构:
Takasaki Univ Hlth & Welf, Grad Sch Hlth Care, Dept Phys Therapy, Takasaki, Gunma, Japan Kurosawa Hosp, Dept Rehabil, Takasaki, Gunma, Japan
机构:
[1] Kurosawa Hosp, Dept Rehabil, Takasaki, Gunma, Japan
[2] Takasaki Univ Hlth & Welf, Grad Sch Hlth Care, Dept Phys Therapy, Takasaki, Gunma, Japan
来源:
关键词:
Speed skating;
Kinematics;
Biomechanics;
Inertial measurement unit;
Reliability;
STATISTICAL-METHODS;
AGREEMENT;
SKATERS;
D O I:
10.7717/peerj.18102
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
Background. . Precise identification of motion phases in long-track speed skating is critical to characterize and optimize performance. This study aimed to estimate the intra- and inter-rater reliability of movement phase identification using inertial measurement units (IMUs) in long-track speed skating. Methods. . We analyzed 15 skaters using IMUs attached to specific body locations during a 500m skate, focusing on the stance phase, and identifying three movement events: Onset, Edge-flip, and Push-off. Reliability was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Results. Results showed high intra- and inter-rater reliability (ICC [1,1]: 0.86 to 0.99; ICC [2,1]: 0.81 to 0.99) across all events. Absolute error ranged from 0.56 to 6.15 ms and from 0.92 to 26.29 ms for intra- and inter-rater reliability, respectively. Minimally detectable change (MDC) ranged from 17.56 to 62.22 ms and from 33.23 to 131.25 ms for intra- and inter-rater reliability, respectively. Discussion. . Despite some additive and proportional errors, the overall error range was within acceptable limits, indicating negligible systematic errors. The measurement error range was small, demonstrating the accuracy of IMUs. IMUs demonstrate high reliability in movement phase identification during speed skating, endorsing their application in sports science for enhanced kinematic studies and training.
引用
收藏
页数:16
相关论文
共 20 条
[1]
Essentials of Statistical Methods for Assessing Reliability and Agreement in Quantitative Imaging
[J].
Anvari, Arash
;
Halpern, Elkan F.
;
Samir, Anthony E.
.
ACADEMIC RADIOLOGY,
2018, 25 (03)
:391-396

Anvari, Arash
论文数: 0 引用数: 0
h-index: 0
机构:
Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA

Halpern, Elkan F.
论文数: 0 引用数: 0
h-index: 0
机构:
Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA

Samir, Anthony E.
论文数: 0 引用数: 0
h-index: 0
机构:
Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2]
Ground Reaction Forces and Kinematics of Ski Jump Landing Using Wearable Sensors
[J].
Bessone, Veronica
;
Petrat, Johannes
;
Schwirtz, Ansgar
.
SENSORS,
2019, 19 (09)

Bessone, Veronica
论文数: 0 引用数: 0
h-index: 0
机构:
Tech Univ Munich, Fac Sport & Hlth Sci, Dept Biomech Sports, D-80992 Munich, Germany Tech Univ Munich, Fac Sport & Hlth Sci, Dept Biomech Sports, D-80992 Munich, Germany

Petrat, Johannes
论文数: 0 引用数: 0
h-index: 0
机构:
Tech Univ Munich, Fac Sport & Hlth Sci, Dept Biomech Sports, D-80992 Munich, Germany
Olymp Training Ctr Bavaria, D-80809 Munich, Germany Tech Univ Munich, Fac Sport & Hlth Sci, Dept Biomech Sports, D-80992 Munich, Germany

Schwirtz, Ansgar
论文数: 0 引用数: 0
h-index: 0
机构:
Tech Univ Munich, Fac Sport & Hlth Sci, Dept Biomech Sports, D-80992 Munich, Germany
Olymp Training Ctr Bavaria, D-80809 Munich, Germany Tech Univ Munich, Fac Sport & Hlth Sci, Dept Biomech Sports, D-80992 Munich, Germany
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
[J].
BLAND, JM
;
ALTMAN, DG
.
LANCET,
1986, 1 (8476)
:307-310

BLAND, JM
论文数: 0 引用数: 0
h-index: 0
机构: NORTHWICK PK HOSP, MRC, CLIN RES CTR, DIV MED STAT, WATFORD RD, HARROW HA1 3UJ, MIDDX, ENGLAND

ALTMAN, DG
论文数: 0 引用数: 0
h-index: 0
机构: NORTHWICK PK HOSP, MRC, CLIN RES CTR, DIV MED STAT, WATFORD RD, HARROW HA1 3UJ, MIDDX, ENGLAND
[4]
Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
[J].
Faisal, Abu Ilius
;
Majumder, Sumit
;
Mondal, Tapas
;
Cowan, David
;
Naseh, Sasan
;
Deen, M. Jamal
.
SENSORS,
2019, 19 (11)

论文数: 引用数:
h-index:
机构:

论文数: 引用数:
h-index:
机构:

论文数: 引用数:
h-index:
机构:

Cowan, David
论文数: 0 引用数: 0
h-index: 0
机构:
St Josephs Healthcare Hamilton, Dept Med, Hamilton, ON L8N 4A6, Canada McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4L8, Canada

Naseh, Sasan
论文数: 0 引用数: 0
h-index: 0
机构:
McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4L8, Canada McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4L8, Canada

Deen, M. Jamal
论文数: 0 引用数: 0
h-index: 0
机构:
McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4L8, Canada McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4L8, Canada
[5]
Accurate Estimation of Running Temporal Parameters Using Foot-Worn Inertial Sensors
[J].
Falbriard, Mathieu
;
Meyer, Frederic
;
Mariani, Benoit
;
Millet, Gregoire P.
;
Aminian, Kamiar
.
FRONTIERS IN PHYSIOLOGY,
2018, 9

Falbriard, Mathieu
论文数: 0 引用数: 0
h-index: 0
机构:
Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, Lausanne, Switzerland Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, Lausanne, Switzerland

Meyer, Frederic
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Lausanne, Inst Sport Sci, Lausanne, Switzerland Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, Lausanne, Switzerland

Mariani, Benoit
论文数: 0 引用数: 0
h-index: 0
机构:
Gait Up SA, Lausanne, Switzerland Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, Lausanne, Switzerland

Millet, Gregoire P.
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Lausanne, Inst Sport Sci, Lausanne, Switzerland Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, Lausanne, Switzerland

Aminian, Kamiar
论文数: 0 引用数: 0
h-index: 0
机构:
Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, Lausanne, Switzerland Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, Lausanne, Switzerland
[6]
Reliability of IMU-Derived Temporal Gait Parameters in Neurological Diseases
[J].
Hansen, Clint
;
Ortlieb, Christian
;
Romijnders, Robbin
;
Warmerdam, Elke
;
Welzel, Julius
;
Geritz, Johanna
;
Maetzler, Walter
.
SENSORS,
2022, 22 (06)

Hansen, Clint
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany

Ortlieb, Christian
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany

Romijnders, Robbin
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany
Univ Kiel, Inst Elect & Informat Engn, Digital Signal Proc & Syst Theory, Kaiserstr 2, D-24143 Kiel, Germany Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany

Warmerdam, Elke
论文数: 0 引用数: 0
h-index: 0
机构:
Saarland Univ, Div Surg, D-66421 Homburg, Germany Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany

Welzel, Julius
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany

Geritz, Johanna
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany

Maetzler, Walter
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany Univ Hosp Schleswig Holstein, Dept Neurol, Arnold Heller Str 3,Haus D, D-24105 Kiel, Germany
[7]
New method to evaluate three-dimensional push-off angle during short-track speed skating using wearable inertial measurement unit sensors
[J].
Kim, Kyungsoo
;
Kim, Jun Seok
;
Purevsuren, Tserenchimed
;
Khuyagbaatar, Batbayar
;
Lee, SuKyoung
;
Kim, Yoon Hyuk
.
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE,
2019, 233 (04)
:476-480

Kim, Kyungsoo
论文数: 0 引用数: 0
h-index: 0
机构:
Kyung Hee Univ, Dept Appl Math, Yongin, South Korea Kyung Hee Univ, Dept Appl Math, Yongin, South Korea

Kim, Jun Seok
论文数: 0 引用数: 0
h-index: 0
机构:
Kyung Hee Univ, Dept Mech Engn, 1732 Deogyeong Daero, Yongin 17104, South Korea Kyung Hee Univ, Dept Appl Math, Yongin, South Korea

Purevsuren, Tserenchimed
论文数: 0 引用数: 0
h-index: 0
机构:
Kyung Hee Univ, Dept Mech Engn, 1732 Deogyeong Daero, Yongin 17104, South Korea Kyung Hee Univ, Dept Appl Math, Yongin, South Korea

Khuyagbaatar, Batbayar
论文数: 0 引用数: 0
h-index: 0
机构:
Kyung Hee Univ, Dept Mech Engn, 1732 Deogyeong Daero, Yongin 17104, South Korea Kyung Hee Univ, Dept Appl Math, Yongin, South Korea

Lee, SuKyoung
论文数: 0 引用数: 0
h-index: 0
机构:
Yonsei Univ, Dept Comp Sci, Seoul, South Korea Kyung Hee Univ, Dept Appl Math, Yongin, South Korea

Kim, Yoon Hyuk
论文数: 0 引用数: 0
h-index: 0
机构:
Kyung Hee Univ, Dept Mech Engn, 1732 Deogyeong Daero, Yongin 17104, South Korea Kyung Hee Univ, Dept Appl Math, Yongin, South Korea
[8]
Performance Characteristics of Long-Track Speed Skaters: A Literature Review
[J].
Konings, Marco J.
;
Elferink-Gemser, Marije T.
;
Stoter, Inge K.
;
van der Meer, Dirk
;
Otten, Egbert
;
Hettinga, Florentina J.
.
SPORTS MEDICINE,
2015, 45 (04)
:505-516

Konings, Marco J.
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Essex, Sch Biol Sci, Ctr Sport & Exercise Sci, Colchester CO4 3SQ, Essex, England
Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9713 AV Groningen, Netherlands Univ Essex, Sch Biol Sci, Ctr Sport & Exercise Sci, Colchester CO4 3SQ, Essex, England

Elferink-Gemser, Marije T.
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9713 AV Groningen, Netherlands
HAN Univ Appl Sci, Inst Studies Sports & Exercise, Arnhem, Netherlands Univ Essex, Sch Biol Sci, Ctr Sport & Exercise Sci, Colchester CO4 3SQ, Essex, England

Stoter, Inge K.
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9713 AV Groningen, Netherlands Univ Essex, Sch Biol Sci, Ctr Sport & Exercise Sci, Colchester CO4 3SQ, Essex, England

van der Meer, Dirk
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9713 AV Groningen, Netherlands Univ Essex, Sch Biol Sci, Ctr Sport & Exercise Sci, Colchester CO4 3SQ, Essex, England

Otten, Egbert
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9713 AV Groningen, Netherlands Univ Essex, Sch Biol Sci, Ctr Sport & Exercise Sci, Colchester CO4 3SQ, Essex, England

Hettinga, Florentina J.
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Essex, Sch Biol Sci, Ctr Sport & Exercise Sci, Colchester CO4 3SQ, Essex, England
Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9713 AV Groningen, Netherlands Univ Essex, Sch Biol Sci, Ctr Sport & Exercise Sci, Colchester CO4 3SQ, Essex, England
[9]
Validation of temporal parameters within the skating sub-techniques when roller skiing on a treadmill, using inertial measurement units
[J].
Meyer, Frederic
;
Seeberg, Trine M.
;
Kocbach, Jan
;
Danielsen, Jorgen
;
Sandbakk, Oyvind
;
Austeng, Andreas
.
PLOS ONE,
2022, 17 (08)

Meyer, Frederic
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Oslo, Dept Informat, Digital Signal Proc Grp, Oslo, Norway Univ Oslo, Dept Informat, Digital Signal Proc Grp, Oslo, Norway

Seeberg, Trine M.
论文数: 0 引用数: 0
h-index: 0
机构:
SINTEF Digital, Smart Sensor Syst, Oslo, Norway Univ Oslo, Dept Informat, Digital Signal Proc Grp, Oslo, Norway

论文数: 引用数:
h-index:
机构:

Danielsen, Jorgen
论文数: 0 引用数: 0
h-index: 0
机构:
Norwegian Univ Sci & Technol, Ctr Elite Sports Res, Dept Neuromed & Movement Sci, Trondheim, Norway Univ Oslo, Dept Informat, Digital Signal Proc Grp, Oslo, Norway

Sandbakk, Oyvind
论文数: 0 引用数: 0
h-index: 0
机构:
Norwegian Univ Sci & Technol, Ctr Elite Sports Res, Dept Neuromed & Movement Sci, Trondheim, Norway Univ Oslo, Dept Informat, Digital Signal Proc Grp, Oslo, Norway

Austeng, Andreas
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Oslo, Dept Informat, Digital Signal Proc Grp, Oslo, Norway Univ Oslo, Dept Informat, Digital Signal Proc Grp, Oslo, Norway
[10]
Differences in V1 and V2 ski skating techniques described by accelerometers
[J].
Myklebust, H.
;
Losnegard, T.
;
Hallen, J.
.
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS,
2014, 24 (06)
:882-893

Myklebust, H.
论文数: 0 引用数: 0
h-index: 0
机构:
Norwegian Sch Sport Sci, Dept Phys Performance, Norwegian Res Ctr Training & Performance, N-0806 Oslo, Norway Norwegian Sch Sport Sci, Dept Phys Performance, Norwegian Res Ctr Training & Performance, N-0806 Oslo, Norway

Losnegard, T.
论文数: 0 引用数: 0
h-index: 0
机构:
Norwegian Sch Sport Sci, Dept Phys Performance, Norwegian Res Ctr Training & Performance, N-0806 Oslo, Norway Norwegian Sch Sport Sci, Dept Phys Performance, Norwegian Res Ctr Training & Performance, N-0806 Oslo, Norway

Hallen, J.
论文数: 0 引用数: 0
h-index: 0
机构:
Norwegian Sch Sport Sci, Dept Phys Performance, Norwegian Res Ctr Training & Performance, N-0806 Oslo, Norway Norwegian Sch Sport Sci, Dept Phys Performance, Norwegian Res Ctr Training & Performance, N-0806 Oslo, Norway