Do neonates hear what we measure? Assessing neonatal ward soundscapes at the neonates' ears

被引:0
作者
Lam, Bhan [1 ]
Fan, Peijin Esther Monica [2 ]
Tay, Yih Yann [2 ]
Poon, Woei Bing [3 ]
Ong, Zhen-Ting [1 ]
Ooi, Kenneth [1 ]
Gan, Woon-Seng [1 ]
Ang, Shin Yuh [2 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[2] Singapore Gen Hosp, Nursing Div, Outram Rd, Singapore 169608, Singapore
[3] Singapore Gen Hosp, Dept Neonatal & Dev Med, Outram Rd, Singapore 169608, Singapore
关键词
Neonatal intensive care; Indoor noise; Hospital soundscape; Binaural; Hospital acoustics; Building acoustics; INTENSIVE-CARE-UNIT; INFANTS BORN; RECOMMENDED STANDARDS; ENVIRONMENTAL NOISE; PRETERM INFANTS; SOUND LEVELS; EXPOSURE;
D O I
10.1016/j.buildenv.2025.112655
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Acoustic guidelines for neonatal intensive care units (NICUs) aim to protect vulnerable neonates from noise-induced physiological harm. However, the lack of recognized international standards for measuring neonatal soundscapes has led to inconsistencies in instrumentation and microphone placement in existing literature, raising concerns about the relevance and effectiveness of these guidelines. This study addresses these gaps through long-term acoustic measurements in an operational NICU and a high-dependency ward. We investigate the influence of microphone positioning, bed placement, and ward layout on the assessment of NICU soundscapes. Beyond traditional A-weighted decibel metrics, this study evaluates C-weighted metrics for low-frequency noise, the occurrence of tonal sounds (e.g., alarms), and transient loud events known to disrupt neonates' sleep. Using linear mixed-effects models with aligned ranks transformation ANOVA (LME-ARTANOVA), our results reveal significant differences in measured noise levels based on microphone placement, highlighting the importance of capturing sound as perceived directly at the neonate's ears. Additionally, bed position and ward layout significantly impact noise exposure, with a NICU bed position consistently exhibiting the highest sound levels across all (psycho)acoustic metrics. These findings support the adoption of binaural measurements along with the integration additional (psycho)acoustic metrics, such as tonality and transient event occurrence rates, to reliably characterize the neonatal auditory experience.
引用
收藏
页数:13
相关论文
共 65 条
  • [1] McMahon E., Wintermark P., Lahav A., Auditory brain development in premature infants: the importance of early experience, Ann. New York Acad. Sci., 1252, 1, pp. 17-24, (2012)
  • [2] Kuhn P., Dufour A., Zores C., The auditory sensitivity of preterm infants toward their atypical auditory environment in the NICU and their attraction to human voices, Early Vocal Contact and Preterm Infant Brain Development, pp. 113-130, (2017)
  • [3] Dahmen J.C., King A.J., Learning to hear: plasticity of auditory cortical processing, Curr. Opin. Neurobiol., 17, 4, pp. 456-464, (2007)
  • [4] Lahav A., Questionable sound exposure outside of the womb: frequency analysis of environmental noise in the neonatal intensive care unit, Acta Paediatr., 104, 1, pp. e14-e19, (2015)
  • [5] Lahav A., Skoe E., An acoustic gap between the NICU and womb: a potential risk for compromised neuroplasticity of the auditory system in preterm infants, Front. Neurosci., 8, (2014)
  • [6] El-Metwally D.E., Medina A.E., The potential effects of NICU environment and multisensory stimulation in prematurity, Pediatr. Res., 88, 2, pp. 161-162, (2020)
  • [7] Retsa C., Turpin H., Geiser E., Ansermet F., Muller-Nix C., Murray M.M., Longstanding auditory sensory and semantic differences in preterm Born children, Brain Topogr., 37, 4, pp. 536-551, (2024)
  • [8] Wachman E.M., Lahav A., The effects of noise on preterm infants in the NICU, Arch. Dis. Child. - Fetal Neonatal Ed., 96, 4, pp. F305-F309, (2011)
  • [9] Kuhn P., Zores C., Pebayle T., Hoeft A., Langlet C., Escande B.T., Astruc D., Dufour A., Infants born very preterm react to variations of the acoustic environment in their incubator from a minimum signal-to-noise ratio threshold of 5 to 10 dBA, Pediatr. Res., 71, 1, pp. 386-392, (2012)
  • [10] Shimizu A., Matsuo H., Sound environments surrounding preterm infants within an occupied closed incubator, J. Pediatr. Nurs., 31, 2, pp. e149-e154, (2016)