Comparison of Diffusion-Weighted MRI Using Single-Shot Echo-Planar Imaging and Split Acquisition of Fast Spin-Echo Signal Imaging, a Non-EPI Technique, in Tumors of the Head and Neck

被引:0
|
作者
van der Hulst, Hedda J. [1 ,2 ,5 ]
Braun, Loes [1 ]
Westerink, Bram [1 ]
Agrotis, Georgios [1 ,6 ]
ter Beek, Leon C. [3 ]
Tissier, Renaud [4 ]
Ahmadian, Milad [1 ,2 ,7 ]
Martens, Roland M. [8 ]
Casselman, Jan W. [10 ,11 ]
Beets-Tan, Regina G. H. [1 ,5 ,12 ]
van den Brekel, Michiel W. M. [2 ,9 ]
Castelijns, Jonas A. [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Netherlands Canc Inst, Dept Head & Neck Oncol & Surg, Amsterdam, Netherlands
[3] Netherlands Canc Inst, Dept Clin Phys, Amsterdam, Netherlands
[4] Netherlands Canc Inst, Biostat Unit, Amsterdam, Netherlands
[5] Univ Maastricht, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
[6] Univ Hosp Larissa, Dept Neurosurg, Thessaly, Greece
[7] Univ Amsterdam, Amsterdam Ctr Language & Commun, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Amsterdam Univ, Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[9] Vrije Univ Amsterdam, Amsterdam Univ, Dept Oral & Maxillofacial Surg, Med Ctr, Amsterdam, Netherlands
[10] Dalhousie Univ, Dept Radiol, Halifax, NS, Canada
[11] Arizona St Lucas Gent, Dept Radiol, Ghent, Belgium
[12] Univ Southern Denmark, Dept Reg Hlth Res, Odense, Denmark
关键词
COEFFICIENT; LESIONS; DWI; ACCURACY;
D O I
10.3174/ajnr.A8529
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI using single-shot echo-planar imaging (DWI-EPI) is susceptible to distortions around air-filled cavities and dental fillings, typical for the head and neck area. Non-EPI, split acquisition of fast spin-echo signals for diffusion imaging (DW-SPLICE) could reduce these distortions and enhance image quality, thereby potentially improving recurrence assessment in squamous cell carcinoma (SCC) of the head and neck region. This study evaluated whether DW-SPLICE is a viable alternative to DWI-EPI through quantitative and qualitative analyses. MATERIALS AND METHODS: The DW-SPLICE sequence was incorporated into the standard 3T head and neck MRI protocol with DWI-EPI. Retrospective analysis was conducted on 2 subgroups: first benign or malignant lesions, and second, posttreatment SCC recurrence. In both subgroups, image quality and distortion were scored by 2 independent radiologists, blinded to the DWI technique and evaluated using mixed-effect linear models. Lesion ADC values were assessed with interclass correlation and Bland-Altman analyses. The delineation geometric similarity of DWI to T1-weighted postcontrast MRI was evaluated using the DSC before and after registration. Recurrence in posttreatment SCC scans was evaluated by the same 2 radiologists blinded to the DWI technique. Recurrence detection rates were then compared between DW-SPLICE and DWI-EPI using mixed logistic regression at 6 months and 1 year postscan follow-up data. RESULTS: From August 2020 to January 2022, fifty-five benign or malignant lesion scans (55 patients) and 74 posttreatment SCC scans (66 patients) were analyzed. DW-SPLICE scored better on image quality and showed less overall distortion than DWI-EPI (0.04 CONCLUSIONS: DW-SPLICE surpasses DWI-EPI on image distortion and quality and improves diagnostic reliability for detecting recurrent or residual SCC on 3T MRI of the head and neck. Consistent use of 1 method for follow-up is advised, because ADC values are not completely interchangeable. Integrating DW-SPLICE can significantly improve tumor assessments in clinical practice.
引用
收藏
页码:774 / 783
页数:10
相关论文
共 50 条
  • [41] Clinical comparison of single-shot EPI, readout-segmented EPI and TGSE-BLADE for diffusion-weighted imaging of cerebellopontine angle tumors on 3 tesla
    Fu, Qing
    Kong, Xiang-Chuang
    Liu, Ding-Xi
    Zhou, Kun
    Guo, Yi-Hao
    Wang, Ming-Fu
    Lei, Zi-Qiao
    Zheng, Chuan-Sheng
    MAGNETIC RESONANCE IMAGING, 2021, 84 : 76 - 83
  • [42] Evaluation of Malignant Breast Lesions Using High-resolution Readout-segmented Diffusion-weighted Echo-planar Imaging: Comparison with Pathology
    Kishimoto, Ayami Ohno
    Kataoka, Masako
    Iima, Mami
    Honda, Maya
    Miyake, Kanae Kawai
    Ohashi, Akane
    Ota, Rie
    Kataoka, Tatsuki
    Sakurai, Takaki
    Toi, Masakazu
    Togashi, Kaori
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (02) : 204 - 215
  • [43] Histogram analysis comparison of readout-segmented and single-shot echo-planar imaging for differentiating luminal from non-luminal breast cancer
    Hu, Yiqi
    Hu, Qilan
    Liu, Zhiqiang
    Huang, Cicheng
    Xia, Liming
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [44] Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Prostate at 3 Tesla: Comparison With Standard Echo-Planar Imaging Technique for Image Quality and Tumor Assessment
    Tamada, Tsutomu
    Ream, Justin M.
    Doshi, Ankur M.
    Taneja, Samir S.
    Rosenkrantz, Andrew B.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (06) : 949 - 956
  • [45] Comparison of apparent diffusion coefficient (ADC) values obtained by echo planar imaging diffusion-weighted imaging (DWI) and radial acquisition regime DWI in low field MRI systems: A phantom study
    Sakoda, K.
    Baba, S.
    RADIOGRAPHY, 2024, 30 (05) : 1290 - 1296
  • [46] High-resolution three-dimensional diffusion-weighted imaging of middle ear cholesteatoma at 3.0 T MRI: Usefulness of 3D turbo field-echo with diffusion-sensitized driven-equilibrium preparation (TFE-DSDE) compared to single-shot echo-planar imaging
    Yamashita, Koji
    Yoshiura, Takashi
    Hiwatashi, Akio
    Obara, Makoto
    Togao, Osamu
    Matsumoto, Nozomu
    Kikuchi, Kazufumi
    Honda, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (09) : E471 - E475
  • [47] Differentiation between cavernous hemangiomas and untreated malignant neoplasms of the liver with free-breathing diffusion-weighted MR imaging: Comparison with T2-weighted fast spin-echo MR imaging
    Soyer, Philippe
    Corno, Lucie
    Boudiaf, Mourad
    Aout, Mounir
    Sirol, Marc
    Place, Vinciane
    Duchat, Florent
    Guerrache, Youcef
    Fargeaudou, Yann
    Vicaut, Eric
    Pocard, Marc
    Hamzi, Lounis
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 316 - 324
  • [48] Comparison between MRI with spin-echo echo-planar diffusion-weighted sequence (DWI) and histology in the diagnosis of soft-tissue tumoursConfronto tra la risonanza magnetica (RM) con sequenze spin echo planar diffusion (DWI) e istologia nella prima diagnosi dei tumori dei tessuti molli
    E. Genovese
    A. Canì
    S. Rizzo
    M. G. Angeretti
    A. Leonardi
    C. Fugazzola
    La radiologia medica, 2011, 116 (4) : 644 - 656
  • [49] Diffusion-Weighted Imaging of Human Carotid Artery Using 2D Single-Shot Interleaved Multislice Inner Volume Diffusion-Weighted Echo Planar Imaging (2D ss-IMIV-DWEPI) at 3T: Diffusion Measurement in Atherosclerotic Plaque
    Kim, Seong-Eun
    Jeong, Eun-Kee
    Shi, Xian-Feng
    Morrell, Glen
    Treiman, Gerald S.
    Parker, Dennis L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 1068 - 1077
  • [50] Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities
    Gatidis, Sergios
    Graf, Hansjoerg
    Weiss, Jakob
    Stemmer, Alto
    Kiefer, Berthold
    Nikolaou, Konstantin
    Notohamiprodjo, Mike
    Martirosian, Petros
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (01) : 57 - 63