Comparison of Diffusion-Weighted MRI Using Single-Shot Echo-Planar Imaging and Split Acquisition of Fast Spin-Echo Signal Imaging, a Non-EPI Technique, in Tumors of the Head and Neck

被引:0
|
作者
van der Hulst, Hedda J. [1 ,2 ,5 ]
Braun, Loes [1 ]
Westerink, Bram [1 ]
Agrotis, Georgios [1 ,6 ]
ter Beek, Leon C. [3 ]
Tissier, Renaud [4 ]
Ahmadian, Milad [1 ,2 ,7 ]
Martens, Roland M. [8 ]
Casselman, Jan W. [10 ,11 ]
Beets-Tan, Regina G. H. [1 ,5 ,12 ]
van den Brekel, Michiel W. M. [2 ,9 ]
Castelijns, Jonas A. [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Netherlands Canc Inst, Dept Head & Neck Oncol & Surg, Amsterdam, Netherlands
[3] Netherlands Canc Inst, Dept Clin Phys, Amsterdam, Netherlands
[4] Netherlands Canc Inst, Biostat Unit, Amsterdam, Netherlands
[5] Univ Maastricht, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
[6] Univ Hosp Larissa, Dept Neurosurg, Thessaly, Greece
[7] Univ Amsterdam, Amsterdam Ctr Language & Commun, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Amsterdam Univ, Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[9] Vrije Univ Amsterdam, Amsterdam Univ, Dept Oral & Maxillofacial Surg, Med Ctr, Amsterdam, Netherlands
[10] Dalhousie Univ, Dept Radiol, Halifax, NS, Canada
[11] Arizona St Lucas Gent, Dept Radiol, Ghent, Belgium
[12] Univ Southern Denmark, Dept Reg Hlth Res, Odense, Denmark
关键词
COEFFICIENT; LESIONS; DWI; ACCURACY;
D O I
10.3174/ajnr.A8529
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI using single-shot echo-planar imaging (DWI-EPI) is susceptible to distortions around air-filled cavities and dental fillings, typical for the head and neck area. Non-EPI, split acquisition of fast spin-echo signals for diffusion imaging (DW-SPLICE) could reduce these distortions and enhance image quality, thereby potentially improving recurrence assessment in squamous cell carcinoma (SCC) of the head and neck region. This study evaluated whether DW-SPLICE is a viable alternative to DWI-EPI through quantitative and qualitative analyses. MATERIALS AND METHODS: The DW-SPLICE sequence was incorporated into the standard 3T head and neck MRI protocol with DWI-EPI. Retrospective analysis was conducted on 2 subgroups: first benign or malignant lesions, and second, posttreatment SCC recurrence. In both subgroups, image quality and distortion were scored by 2 independent radiologists, blinded to the DWI technique and evaluated using mixed-effect linear models. Lesion ADC values were assessed with interclass correlation and Bland-Altman analyses. The delineation geometric similarity of DWI to T1-weighted postcontrast MRI was evaluated using the DSC before and after registration. Recurrence in posttreatment SCC scans was evaluated by the same 2 radiologists blinded to the DWI technique. Recurrence detection rates were then compared between DW-SPLICE and DWI-EPI using mixed logistic regression at 6 months and 1 year postscan follow-up data. RESULTS: From August 2020 to January 2022, fifty-five benign or malignant lesion scans (55 patients) and 74 posttreatment SCC scans (66 patients) were analyzed. DW-SPLICE scored better on image quality and showed less overall distortion than DWI-EPI (0.04 CONCLUSIONS: DW-SPLICE surpasses DWI-EPI on image distortion and quality and improves diagnostic reliability for detecting recurrent or residual SCC on 3T MRI of the head and neck. Consistent use of 1 method for follow-up is advised, because ADC values are not completely interchangeable. Integrating DW-SPLICE can significantly improve tumor assessments in clinical practice.
引用
收藏
页码:774 / 783
页数:10
相关论文
共 50 条
  • [21] Comparison between MRI with spin-echo echo-planar diffusion-weighted sequence (DWI) and histology in the diagnosis of soft-tissue tumours
    Genovese, E.
    Cani, A.
    Rizzo, S.
    Angeretti, M. G.
    Leonardi, A.
    Fugazzola, C.
    RADIOLOGIA MEDICA, 2011, 116 (04): : 644 - 656
  • [22] Comparison of accuracy of intravoxel incoherent motion and apparent diffusion coefficient techniques for predicting malignancy of head and neck tumors using half-Fourier single-shot turbo spin-echo diffusion-weighted imaging
    Sakamoto, Junichiro
    Imaizumi, Akiko
    Sasaki, Yoshinori
    Kamio, Takashi
    Wakoh, Mamoru
    Otonari-Yamamoto, Mika
    Sano, Tsukasa
    MAGNETIC RESONANCE IMAGING, 2014, 32 (07) : 860 - 866
  • [23] Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study
    Yoshida, Tsukasa
    Urikura, Atsushi
    Shirata, Kensei
    Nakaya, Yoshihiro
    Terashima, Shingo
    Hosokawa, Yoichiro
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1065)
  • [24] Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T
    Liu, Wenguang
    Liu, Hui
    Xie, Simin
    Masokano, Ismail Bilal
    Bai, Yu
    Wang, Xiao
    Zhong, Linhui
    Wu, Yi
    Nie, Jilin
    Zhou, Gaofeng
    Pei, Yigang
    Li, Wenzheng
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [25] Advanced diffusion weighted imaging of the prostate: Comparison of readout-segmented multi-shot, parallel-transmit and single-shot echo-planar imaging
    Klingebiel, M.
    Ullrich, T.
    Quentin, M.
    Bonekamp, D.
    Aissa, J.
    Mally, D.
    Arsov, C.
    Albers, P.
    Antoch, G.
    Schimmoeller, L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130
  • [26] Values of Apparent Diffusion Coefficient and Lesion-to-Spinal Cord Signal Intensity in Diagnosing Solitary Pulmonary Lesions: Turbo Spin-Echo versus Echo-Planar Imaging Diffusion-Weighted Imaging
    Lei, Qiang
    Wan, Qi
    Liu, Lishan
    Hu, Jianfeng
    Zuo, Wei
    Li, Jianneng
    Jiang, Guihua
    Li, Xinchun
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [27] Diagnostic performance of multishot echo-planar imaging (RESOLVE) and non-echo-planar imaging (HASTE) diffusion-weighted imaging in cholesteatoma with an emphasis on signal intensity ratio measurement
    Bozer, Ahmet
    Adibelli, Zehra Hilal
    Yener, Yesim
    Dalgic, Abdullah
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (06): : 370 - 377
  • [28] Diffusion Tensor Imaging of the Brachial Plexus: A Comparison between Readout-segmented and Conventional Single-shot Echo-planar Imaging
    Ho, Michael J.
    Ciritsis, Alexander
    Manoliu, Andrei
    Stieltjes, Bram
    Marcon, Magda
    Andreisek, Gustav
    Kuhn, Felix Pierre
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (02) : 150 - 157
  • [29] Detection of cholesteatoma: 2D BLADE turbo gradient- and spin-echo imaging versus readout-segmented echo-planar diffusion-weighted imaging
    Lin, Mengyan
    Lin, Naier
    Sheng, Yaru
    Sha, Yan
    Zhang, Zhongshuai
    Zhou, Kun
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (11) : 5223 - 5229
  • [30] High resolution diffusion weighted magnetic resonance imaging of the pancreas using reduced field of view single-shot echo-planar imaging at 3 T
    Ma, Chao
    Li, Yan-jun
    Pan, Chun-shu
    Wang, He
    Wang, Jian
    Chen, Shi-yue
    Lu, Jian-ping
    MAGNETIC RESONANCE IMAGING, 2014, 32 (02) : 125 - 131