Comparison of Diffusion-Weighted MRI Using Single-Shot Echo-Planar Imaging and Split Acquisition of Fast Spin-Echo Signal Imaging, a Non-EPI Technique, in Tumors of the Head and Neck

被引:0
|
作者
van der Hulst, Hedda J. [1 ,2 ,5 ]
Braun, Loes [1 ]
Westerink, Bram [1 ]
Agrotis, Georgios [1 ,6 ]
ter Beek, Leon C. [3 ]
Tissier, Renaud [4 ]
Ahmadian, Milad [1 ,2 ,7 ]
Martens, Roland M. [8 ]
Casselman, Jan W. [10 ,11 ]
Beets-Tan, Regina G. H. [1 ,5 ,12 ]
van den Brekel, Michiel W. M. [2 ,9 ]
Castelijns, Jonas A. [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Netherlands Canc Inst, Dept Head & Neck Oncol & Surg, Amsterdam, Netherlands
[3] Netherlands Canc Inst, Dept Clin Phys, Amsterdam, Netherlands
[4] Netherlands Canc Inst, Biostat Unit, Amsterdam, Netherlands
[5] Univ Maastricht, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
[6] Univ Hosp Larissa, Dept Neurosurg, Thessaly, Greece
[7] Univ Amsterdam, Amsterdam Ctr Language & Commun, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Amsterdam Univ, Med Ctr, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[9] Vrije Univ Amsterdam, Amsterdam Univ, Dept Oral & Maxillofacial Surg, Med Ctr, Amsterdam, Netherlands
[10] Dalhousie Univ, Dept Radiol, Halifax, NS, Canada
[11] Arizona St Lucas Gent, Dept Radiol, Ghent, Belgium
[12] Univ Southern Denmark, Dept Reg Hlth Res, Odense, Denmark
关键词
COEFFICIENT; LESIONS; DWI; ACCURACY;
D O I
10.3174/ajnr.A8529
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI using single-shot echo-planar imaging (DWI-EPI) is susceptible to distortions around air-filled cavities and dental fillings, typical for the head and neck area. Non-EPI, split acquisition of fast spin-echo signals for diffusion imaging (DW-SPLICE) could reduce these distortions and enhance image quality, thereby potentially improving recurrence assessment in squamous cell carcinoma (SCC) of the head and neck region. This study evaluated whether DW-SPLICE is a viable alternative to DWI-EPI through quantitative and qualitative analyses. MATERIALS AND METHODS: The DW-SPLICE sequence was incorporated into the standard 3T head and neck MRI protocol with DWI-EPI. Retrospective analysis was conducted on 2 subgroups: first benign or malignant lesions, and second, posttreatment SCC recurrence. In both subgroups, image quality and distortion were scored by 2 independent radiologists, blinded to the DWI technique and evaluated using mixed-effect linear models. Lesion ADC values were assessed with interclass correlation and Bland-Altman analyses. The delineation geometric similarity of DWI to T1-weighted postcontrast MRI was evaluated using the DSC before and after registration. Recurrence in posttreatment SCC scans was evaluated by the same 2 radiologists blinded to the DWI technique. Recurrence detection rates were then compared between DW-SPLICE and DWI-EPI using mixed logistic regression at 6 months and 1 year postscan follow-up data. RESULTS: From August 2020 to January 2022, fifty-five benign or malignant lesion scans (55 patients) and 74 posttreatment SCC scans (66 patients) were analyzed. DW-SPLICE scored better on image quality and showed less overall distortion than DWI-EPI (0.04 CONCLUSIONS: DW-SPLICE surpasses DWI-EPI on image distortion and quality and improves diagnostic reliability for detecting recurrent or residual SCC on 3T MRI of the head and neck. Consistent use of 1 method for follow-up is advised, because ADC values are not completely interchangeable. Integrating DW-SPLICE can significantly improve tumor assessments in clinical practice.
引用
收藏
页码:774 / 783
页数:10
相关论文
共 50 条
  • [1] Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck
    Mikayama, Ryoji
    Yabuuchi, Hidetake
    Sonoda, Shinjiro
    Kobayashi, Koji
    Nagatomo, Kazuya
    Kimura, Mitsuhiro
    Kawanami, Satoshi
    Kamitani, Takeshi
    Kumazawa, Seiji
    Honda, Hiroshi
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 316 - 324
  • [2] Diffusion-weighted imaging in the prostate: an apparent diffusion coefficient comparison of half-Fourier acquisition single-shot turbo spin-echo and echo planar imaging
    Babourina-Brooks, Ben
    Cowin, Gary J.
    Wang, Deming
    MAGNETIC RESONANCE IMAGING, 2012, 30 (02) : 189 - 194
  • [3] Assessment of Mediastinal Tumors With Diffusion-Weighted Single-Shot Echo-Planar MRI
    Razek, Ahmed Abdel
    Elmorsy, Ahmed
    Elshafey, Mohsen
    Elhadedy, Tamer
    Hamza, Osama
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 535 - 540
  • [4] Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck
    Panyarak, Wannakamon
    Chikui, Toru
    Yamashita, Yasuo
    Kamitani, Takeshi
    Yoshiura, Kazunori
    ACADEMIC RADIOLOGY, 2019, 26 (10) : E305 - E316
  • [5] Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver
    Kim, Yeun-Yoon
    Kim, Myeong-Jin
    Gho, Sung-Min
    Seo, Nieun
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
  • [6] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Hong, Ben-Zu
    Li, Xin-Feng
    Lin, Jian-Qing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (20) : 6374 - 6380
  • [7] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [8] Intravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and Echo-Planar Imaging
    Wan, Qi
    Lei, Qiang
    Wang, Peng
    Hu, Jianfeng
    Zhang, Tianjing
    Yu, Deng
    Li, Xinchun
    Liang, Changhong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 334 - 340
  • [9] Diffusion-weighted imaging (DWI) in MR mammography (MRM): clinical comparison of echo planar imaging (EPI) and half-Fourier single-shot turbo spin echo (HASTE) diffusion techniques
    Baltzer, P. A. T.
    Renz, D. M.
    Herrmann, K. -H.
    Dietzel, M.
    Krumbein, I.
    Gajda, M.
    Camara, O.
    Reichenbach, J. R.
    Kaiser, W. A.
    EUROPEAN RADIOLOGY, 2009, 19 (07) : 1612 - 1620
  • [10] Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance
    Xu, Xiaoquan
    Wang, Yanjun
    Hu, Hao
    Su, Guoyi
    Liu, Hu
    Shi, Haibin
    Wu, Feiyun
    ACTA RADIOLOGICA, 2017, 58 (12) : 1457 - 1467