Smart electronic device for air quality and exposure risk assessment

被引:0
|
作者
Taamte, Jacob Mbarndouka [1 ]
Siaka, Yvette Flore Tchuente [1 ]
Nducol, Nasser [1 ]
Yakum-Ntaw Younui, Susan [1 ]
Ahmadou, Gouroudja [1 ]
Essama, Rene Claude Etende [1 ]
Noube, Michaux Kountchou [1 ]
Saidou [1 ,2 ]
机构
[1] Inst Geol & Min Res, Res Ctr Nucl Sci & Technol, POB 4110, Yaounde, Cameroon
[2] Univ Yaounde I, Fac Sci, Nucl Phys Lab, Yaounde, Cameroon
关键词
Sensors; smart electronic device; air quality monitoring; health risk assessment; microcontroller board; POLLUTION; HEALTH;
D O I
10.1080/23080477.2025.2452044
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This article reports on the measurement of air pollutants and assessment of health exposure risks in two reference hospitals in the city of Yaound & eacute;, using a locally manufactured smart electronic device for the measurement of highly toxic air pollutants. This low-cost device is based on an Atmega328 microcontroller, toxic gas sensors (O3, PM2.5, CO, CO2 and NO2), temperature (T), relative humidity (RH) sensors, and XBee modules to establish the Internet of Things (IoT). In each of the two hospitals, 2 weeks of measurements conducted from October 15 to 30, 2023 at Biyem-assi Hospital and from September 1 to 15, 2023 at Central Hospital. The average values obtained were 0.96 +/- 0.06 ppm and 0.37 +/- 0.09 ppm for O3, 39.66 +/- 10 mu g/m3 and 39.72 +/- 10 mu g/m3 for PM2.5, 0.41 +/- 0.01 ppm and 0.42 +/- 0.02 ppm for CO, 316.55 +/- 63 ppm and 305.84 +/- 89 ppm for CO2, and 0.43 +/- 0.01 ppm and 0.45 +/- 0,02 ppm for NO2 in Biyem-assi and Central Hospitals, respectively. These values were used to assess the risk of exposure through the Air Quality Index (AQI) and the Air Quality Health Index (AQHI2.5).
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Indoor air quality prediction systems for smart environments: A systematic review
    Saini, Jagriti
    Dutta, Maitreyee
    Marques, Goncalo
    JOURNAL OF AMBIENT INTELLIGENCE AND SMART ENVIRONMENTS, 2020, 12 (05) : 433 - 453
  • [32] Study of the Suitability of a Personal Exposure Monitor to Assess Air Quality
    Aljofi, Halah E.
    Bannan, Thomas J.
    Flynn, Michael
    Evans, James
    Topping, David
    Matthews, Emily
    Diez, Sebastian
    Edwards, Pete
    Coe, Hugh
    Brison, Daniel R.
    van Tongeren, Martie
    Johnstone, Edward D.
    Povey, Andrew
    ATMOSPHERE, 2024, 15 (03)
  • [33] Exposure Assessment of Air Pollution in Lungs
    Paul, Akshoy Ranjan
    Jain, Anuj
    Saha, Suvash C.
    ATMOSPHERE, 2022, 13 (11)
  • [34] Human Exposure Assessment for Air Pollution
    Han, Bin
    Hu, Li-Wen
    Bai, Zhipeng
    AMBIENT AIR POLLUTION AND HEALTH IMPACT IN CHINA, 2017, 1017 : 27 - 57
  • [35] Sensors for indoor air quality monitoring and assessment through Internet of Things: a systematic review
    Saini, Jagriti
    Dutta, Maitreyee
    Marques, Goncalo
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2021, 193 (02)
  • [36] Assessment of Air Quality in two Different Urban Localities
    Al-Harbi, M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2014, 8 (01) : 15 - 26
  • [37] Carcinogenic Risk Assessment among Children and Adult due to Exposure to Toxic Air Pollutants
    Yousefi, Homayon
    Lak, Elena
    Mohammadi, Mohammad Javad
    Shahriyari, Habib Allah
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (16) : 23015 - 23025
  • [38] Maternal exposure to ambient air pollutants and risk of congenital anomalies
    Rankin, Judith
    Chadwick, Tom
    Natarajan, Malathi
    Howel, Denise
    Pearce, Mark S.
    Pless-Mulloli, Tanja
    ENVIRONMENTAL RESEARCH, 2009, 109 (02) : 181 - 187
  • [39] Evaluation of the Air Quality Index as a Risk Communication Tool
    Perlmutt, Lars D.
    Cromar, Kevin R.
    JOURNAL OF ENVIRONMENTAL HEALTH, 2019, 81 (06) : 8 - 15
  • [40] A Consumer-Based Smart Home with Indoor Air Quality Monitoring System
    Patil, Kailas
    Laad, Meena
    Kamble, Aakash
    Laad, Shivani
    IETE JOURNAL OF RESEARCH, 2019, 65 (06) : 758 - 770