Impact of Surgeons' Experience on Implant Placement Accuracy Using a Dynamic Navigation System: A Cadaver Pilot Study

被引:0
作者
Pera, Francesco [1 ]
Vocaturo, Camillo [1 ]
Crupi, Armando [1 ]
Longhi, Beatrice [1 ]
Campagna, Alessandro [1 ]
Fiorino, Antonino [2 ]
Gibello, Umberto [1 ,3 ]
Roccuzzo, Andrea [4 ,5 ,6 ,7 ]
机构
[1] Univ Turin, Dept Surg Sci, CIR Dent Sch, I-10126 Turin, Italy
[2] Univ Naples Federico II, Dept Neurosci Reprod & Odontostomatol Sci, I-80131 Naples, Italy
[3] Politecn Torino, DIMEAS, I-10129 Turin, Italy
[4] Shanghai Jiao Tong Univ, Shanghai People Hosp 9, Inst Integrated Oral Craniofacial & Sensory Res, Shanghai Perio Implant Innovat Ctr,Sch Med, Shanghai 200115, Peoples R China
[5] Shanghai Jiao Tong Univ, Shanghai People Hosp 9, Dept Oral & Maxillofacial Implantol, Sch Med, Shanghai 200115, Peoples R China
[6] Univ Bern, Sch Dent Med, Dept Periodontol, CH-3010 Bern, Switzerland
[7] Univ Bern, Sch Dent Med, Unit Practice Based Res, CH-3010 Bern, Switzerland
来源
PROSTHESIS | 2025年 / 7卷 / 01期
关键词
dental implants; dynamic computer-assisted surgery; computer-guided implantology; navigation systems; COMPUTER-TECHNOLOGY APPLICATIONS; SINGLE CROWNS; DENTISTRY;
D O I
10.3390/prosthesis7010020
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Objectives: The study's objective was to evaluate the accuracy of dynamic computer-assisted surgical implant placement systems during practical training on fresh defrozen cephali. Methods: Three defrozen cephali with terminal dentition received a total of 26 implants (15 4.3 x 13 mm and 11 4.3 x 13 mm, Nobel Biocare Service AG (Zrich-Flughafen Switzerland)) following a standardized protocol: a digital scanning and planning protocol followed by dynamic navigation surgery (X-Guide, X-Nav Technologies, LLC, Lansdale, PA, USA). All surgical interventions were performed by two surgeons: a senior oral surgeon (OE) with more than 5 years of implant dentistry experience and a non-experienced surgeon (NE). Results: Different linear and angular measurements (i.e., deviation shoulder point; deviation tip point; depth deviation shoulder point; depth deviation tip point; B/L and M/D angular deviations) were calculated in duplicate to estimate the discrepancy of the virtual digital planning with respect to the real clinical scenario. The differences between the two operators were also explored. The results of the bivariate analysis detected clinical negligible differences between the operators, without any statistically significant differences for all investigated parameters (p > 0.05). Conclusions: The preliminary positive findings of this pilot study suggest that the investigated dynamic navigation system could be a viable and safe technique for implant surgery and may offer additional safety benefits to non-experienced operators, despite the required learning.
引用
收藏
页数:13
相关论文
共 42 条
[31]   Digital versus conventional prosthetic workflow for dental students providing implant-supported single crowns: A randomized crossover study [J].
Seth, Chahak ;
Bawa, Annika ;
Gotfredsen, Klaus .
JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03) :450-456
[32]   Comparison of implant placement accuracy in two different preoperative digital workflows: navigated vs. pilot-drill-guided surgery [J].
Spille, Johannes ;
Jin, Feilu ;
Behrens, Eleonore ;
Acil, Yahya ;
Lichtenstein, Jurgen ;
Naujokat, Hendrik ;
Guelses, Aydin ;
Floerke, Christian ;
Wiltfang, Joerg .
INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
[33]   The influence of dental experience on a dental implant navigation system [J].
Sun, Ting-Mao ;
Lee, Huey-Er ;
Lan, Ting-Hsun .
BMC ORAL HEALTH, 2019, 19 (01)
[34]   The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis [J].
Tahmaseb, Ali ;
Wu, Viviane ;
Wismeijer, Daniel ;
Coucke, Wim ;
Evans, Christopher .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 :416-435
[35]   Computer Technology Applications in Surgical Implant Dentistry: A Systematic Review [J].
Tahmaseb, Ali ;
Wismeijer, Daniel ;
Coucke, Wim ;
Derksen, Wiebe .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 :25-42
[36]   Different techniques of static/dynamic guided implant surgery: modalities and indications [J].
Vercruyssen, Marjolein ;
Fortin, Thomas ;
Widmann, Gerlig ;
Jacobs, Reinhilde ;
Quirynen, Marc .
PERIODONTOLOGY 2000, 2014, 66 (01) :214-227
[37]   Performance of novice versus experienced surgeons for dental implant placement with freehand, static guided and dynamic navigation approaches [J].
Wang, Xiaotong ;
Shujaat, Sohaib ;
Meeus, Jan ;
Shaheen, Eman ;
Legrand, Paul ;
Lahoud, Pierre ;
Gerhardt, Mauricio do Nascimento ;
Jacobs, Reinhilde .
SCIENTIFIC REPORTS, 2023, 13 (01)
[38]   Influence of experience on dental implant placement: an in vitro comparison of freehand, static guided and dynamic navigation approaches [J].
Wang, Xiaotong ;
Shaheen, Eman ;
Shujaat, Sohaib ;
Meeus, Jan ;
Legrand, Paul ;
Lahoud, Pierre ;
do Nascimento Gerhardt, Mauricio ;
Politis, Constantinus ;
Jacobs, Reinhilde .
INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
[39]   Accuracy of dynamic navigation in implant surgery: A systematic review and meta-analysis [J].
Wei, Shi-Min ;
Zhu, Yu ;
Wei, Jian-Xu ;
Zhang, Chu-Nan ;
Shi, Jun-Yu ;
Lai, Hong-Chang .
CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (04) :383-393
[40]  
Widmann G, 2010, INT J ORAL MAX IMPL, V25, P491