Accurate fault location estimation in a partially coupled circuit line using Takagi method

被引:0
|
作者
Abhijith [1 ,3 ]
Aleena, M. [1 ,3 ]
Vinod, V. [1 ,3 ]
Kumar, P. R. Sunil [2 ,3 ]
机构
[1] Govt Engn Coll Barton Hill, Dept Elect Engn, Trivandrum 695035, Kerala, India
[2] Govt Engn Coll Idukki, Dept Elect & Elect Engn, Idukki 685603, Kerala, India
[3] APJ Abdul Kalam Technol Univ, Thiruvananthapuram 695016, Kerala, India
关键词
Distance relay; Partially coupled line; Superimposed sequence current; Takagi method; Zero sequence current; PARALLEL TRANSMISSION-LINES; ALGORITHM; PROTECTION; SCHEME;
D O I
10.1016/j.epsr.2024.111164
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the event of a Single Line to Ground (SLG) fault, the zero-sequence current associated with the faulty line provides sufficient input for the distance relay to calculate the fault location within a single-circuit line. However, the mutual coupling effect within a double circuit line causes the relay protection algorithm to become more complex. Consequently, the relay utilizes zero sequence currents from both the faulty and healthy lines to overcome the challenges related to under reach and over reach scenarios. The Takagi method and its modified variation is suitably framed to predict the magnitude and phase angle of the zero sequence current in the adjacent healthy line. This information enables the proposed scheme to iteratively and precisely determine the fault location. The method is equally effective for both fully coupled and partially coupled lines operating independently of any communication infrastructure. In the proposed scheme, the fault location error remains under 1% even incases of high resistance faults. PSCAD simulations are conducted across different circuit configurations and the results have been satisfactory. Moreover, by employing an angle correction technique, this method extends its capability to deliver favourable outcomes for non-homogeneous circuits. Furthermore, the effectiveness of the proposed scheme is ascertained by testing the algorithm in a mutually coupled transmission line prototype established in the laboratory.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Partially coupled transmission line fault location using single-ended measurements
    Duan, Mengzhao
    Ye, Aoshuang
    Liu, Yu
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 233
  • [2] Single -terminal fault location in HVDC lines with accurate wave velocity estimation
    Dardengo, Victor P.
    Fardin, Jussara F.
    de Almeida, Madson C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 194
  • [3] An Accurate Fault Location Method for Multi-Circuit Series Compensated Transmission Lines
    Gajare, Swaroop
    Pradhan, Ashok Kumar
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (01) : 572 - 580
  • [4] A hybrid method for fault location estimation in a fixed series compensated lines
    Swetapadma, Aleena
    Yadav, Anamika
    MEASUREMENT, 2018, 123 : 8 - 18
  • [5] Double-Circuit Transmission-Line Fault Location Utilizing Synchronized Current Phasors
    Kang, Ning
    Liao, Yuan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 1040 - 1047
  • [6] An enhanced fault detection and location estimation method for TCSC compensated line connecting wind farm
    Sahoo, Biswajit
    Samantaray, Subhransu Ranjan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 96 : 432 - 441
  • [7] Adaptive Fault Location Algorithm for Double circuit Line
    Upadhiya, Ajit Kumar
    Sarangi, Saumendra
    Rao, Gade Kesava
    Painuli, Shefali
    2018 INTERNATIONAL CONFERENCE ON POWER ENERGY, ENVIRONMENT AND INTELLIGENT CONTROL (PEEIC), 2018, : 801 - 806
  • [8] Double-Circuit Transmission-Line Fault Location With the Availability of Limited Voltage Measurements
    Kang, Ning
    Liao, Yuan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (01) : 325 - 336
  • [9] Accurate Transmission Line Fault Location Considering Shunt Capacitances Without Utilizing Line Parameters
    Xiu, Wanjing
    Liao, Yuan
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2011, 39 (16) : 1783 - 1794
  • [10] Fault location in UPFC compensated double circuit transmission line using negative sequence current phasors
    Kundu , Madhumita
    Debnath, Sudipta
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 184