An automated scanning contactless conductivity detection device for microfluidic isoelectric focusing

被引:0
|
作者
Dai, Haozheng [1 ]
Tian, Youli [1 ]
Tao, Zhimin [1 ]
Chen, Ke-Er [1 ]
Liu, Weiwen [1 ]
Zhang, Qiang [1 ]
Cao, Chengxi [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Sensing Sci & Engn, Sch Elect Informat & Elect Engn, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Life Sci & Biotechnol, State Key Lab Microbial Metab, Shanghai 200240, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Scanning contactless conductivity detection; Microfluidic isoelectric focusing; Quantitative analysis; And dynamic monitoring; CAPILLARY-ELECTROPHORESIS; MICROCHIP; PROTEINS; CHIP; MOBILIZATION; PEPTIDES;
D O I
10.1016/j.snb.2025.137308
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isoelectric focusing (IEF) is widely used for protein separation and enrichment, with various methods available for detecting focused protein bands. While conventional capacitively coupled contactless conductivity detection (C4D) reduced costs and enhanced portability by eliminating optical equipment, it still required an additional mobilization step due to its single-point detection method. To address this limitation, herein we designed a novel device of scanning C4D (sC4D) for microfluidic IEF. At first, we developed an automated device of sC4D which was integrated with IEF chip for protein separation. Second, we designed the relevant software for system control and real-time conductivity measurement. Third, by using equine myoglobin as a model protein we achieved quantitative detection with a linear range of 0.2-2.5 mg/mL and a limit of detection (LOD) of 0.05 mg/mL, demonstrating the feasibility of the method and platform. In contrast to the conventional C4D with single-point detection, the developed sC4D could reduce the detection time of protein band from 760 sec to 25 sec without chemical or pressure mobilization of pH gradient, and without significant deterioration of resolution, and particularly could monitor the dynamic process of IEF and cathode drift of pH gradient. These results indicate that the designed sC4D device might serve as a reliable alternative for microfluidic IEF detection and holds significant potential for applications in various electrophoretic analysis fields in the future.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Fast electrophoresis in conventional capillaries by employing a rapid injection device and contactless conductivity detection
    Andrea Rainelli
    Peter C. Hauser
    Analytical and Bioanalytical Chemistry, 2005, 382 : 789 - 794
  • [42] Use of isoelectric focusing for sample preconditioning in a microfluidic electrochemical flow cell
    Cabrera, CR
    Macounová, K
    Holl, MR
    Yager, P
    1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, : 357 - 360
  • [43] Generation of natural pH gradients in microfluidic channels for use in isoelectric focusing
    Macounová, K
    Cabrera, CR
    Holl, MR
    Yager, P
    ANALYTICAL CHEMISTRY, 2000, 72 (16) : 3745 - 3751
  • [44] CAPILLARY ISOELECTRIC-FOCUSING WITH IMAGING DETECTION
    WU, JQ
    PAWLISZYN, J
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (9-10): : 1891 - 1902
  • [45] Conductivity properties of carrier ampholyte pH gradients in isoelectric focusing
    Stoyanov, AV
    Das, C
    Fredrickson, CK
    Fan, ZH
    ELECTROPHORESIS, 2005, 26 (02) : 473 - 479
  • [46] Microfluidic high-resolution free-flow isoelectric focusing
    Kohlheyer, Dietrich
    Eijkel, Jan C. T.
    Schlautmann, Stefan
    van den Berg, Albert
    Schasfoort, Richard B. M.
    ANALYTICAL CHEMISTRY, 2007, 79 (21) : 8190 - 8198
  • [47] Microfluidic contactless conductivity cytometer for electrical cell sensing and counting
    Sun, Duanping
    Lu, Jing
    Chen, Zuanguang
    RSC ADVANCES, 2015, 5 (73): : 59306 - 59313
  • [48] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Schnell, E
    Volgger, D
    Bonn, GK
    ANALYTICAL CHEMISTRY, 1998, 70 (03) : 563 - 567
  • [49] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Mayrhofer, K
    Schnell, E
    Bonn, GK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U162 - U162
  • [50] An axisymmetric flow-focusing microfluidic device
    Takeuchi, S
    Garstecki, P
    Weibel, DB
    Whitesides, GM
    ADVANCED MATERIALS, 2005, 17 (08) : 1067 - +