Optimizing double-pass solar air collector efficiency: Impact of a perforated discrete V-angled fins

被引:1
作者
Machi, Maytham H. [1 ,3 ]
Farkas, Istvan [2 ]
Buzas, Janos [2 ]
机构
[1] Hungarian Univ Agr & Life Sci, Doctoral Sch Mech Engn, Pater K u 1, H-2100 Godollo, Hungary
[2] Hungarian Univ Agr & Life Sci, Inst Technol, Pater K U 1, H-2100 Godollo, Hungary
[3] Univ Kufa, Fac Engn, Dept Mech Engn, Najaf, Iraq
关键词
Efficiency enhancement; Outlet temperature; ribs; Solar air heater; Thermal performance; THERMAL PERFORMANCE; HEAT-TRANSFER; OPTIMIZATION; ROUGHNESS; RIBS;
D O I
10.1016/j.egyr.2025.01.057
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The current study evaluates the impact of newly designed perforated discrete V- angled fins on the thermal efficiency of double pass solar air collectors (DPSACs). While previous studies have examined various fin shapes for heat transfer enhancement, no research has focused on discrete V- angled fins specifically within DPSACs. Addressing this gap, the objective of this study is to assess the effectiveness of three unique configurations of the V- angled fin design: Type I (aligned parallel to airflow), Type II (angled at 45 & ring; to airflow), and Type III (perpendicular to airflow). Experiments compared a finned collector against a standard smooth model at airflow rates of 0.00932 kg/s, 0.01143 kg/s, and 0.01311 kg/s to determine the influence of fin presence and orientation on DPSAC performance. The results demonstrated the finned collector consistently outperformed the smooth collector, achieving relative daily efficiency improvements ranging from 4.1 % to 9.1 %. Specifically, Type I improved between 4.1 % and 5.1 %, Type II showed gains between 5.9 % and 9.1 %, and Type III achieved relative improvements between 4.3 % and 6.1 %. These findings highlight the critical role of fin orientation, with Type II demonstrating the greatest potential for optimizing heat transfer and overall efficiency. This study provides foundational insights for DPSAC design, confirming that perforated discrete V-angled fins significantly enhance collector performance and offering new directions for solar thermal collector innovation.
引用
收藏
页码:2021 / 2034
页数:14
相关论文
共 34 条
  • [21] Analytical and Experimental Study of Recycling Baffled Double-Pass Solar Air Heaters with Attached Fins
    Ho, Chii Dong
    Chang, Hsuan
    Wang, Rei Chi
    Lin, Chun Sheng
    ENERGIES, 2013, 6 (04): : 1821 - 1842
  • [22] Prediction of thermal efficiency of double pass solar air heater having discrete multi V and staggered ribs
    Ravi, Ravi Kant
    Kumar, Sanjay
    Kumar, Mukesh
    Kumar, Manoj
    Verma, Vikas
    Alam, Tabish
    Yadav, Anil Singh
    Sharma, Abhishek
    HEAT TRANSFER, 2025, 54 (01) : 41 - 65
  • [23] Thermal analysis of a new double-pass solar air heater using perforated absorber and porous materials: An experimental study
    Farzan, Hadi
    Zaim, Ehsan Hasan
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 38
  • [24] Thermal Evaluation of a Double-Pass Unglazed Solar Air Heater with Perforated Plate and Wire Mesh Layers
    Mahmood, Afaq Jasim
    SUSTAINABILITY, 2020, 12 (09)
  • [25] Computational fluid dynamical analysis of turbulent flow in a channel equipped with double-pass solar air collector
    Saim, Rachid
    Abderrahim, Asma
    Oztop, Hakan F.
    Abbdoui, Said
    Al-Salem, Khaled
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2015, 15 (06): : 70 - 76
  • [26] Experimental and thermodynamic analysis of solar air dryer equipped with V-groove double pass collector: Techno-economic and exergetic measures
    Hassan, Ali
    Nikbahkt, Ali M.
    Welsh, Zachary
    Yarlagadda, Prasad
    Fawzia, Sabrina
    Karim, Azharul
    ENERGY CONVERSION AND MANAGEMENT-X, 2022, 16
  • [27] Efficiency Enhancement in Double-Pass Perforated Glazed Solar Air Heaters with Porous Beds: Taguchi-Artificial Neural Network Optimization and Cost-Benefit Analysis
    Vaziri, Roozbeh
    Oladipo, Akeem Adeyemi
    Sharifpur, Mohsen
    Taher, Rani
    Ahmadi, Mohammad Hossein
    Issakhov, Alibek
    SUSTAINABILITY, 2021, 13 (21)
  • [28] Heat transfer and friction factor correlations development for double pass solar air heater artificially roughened with perforated multi-V ribs
    Singh, Varun Pratap
    Jain, Siddharth
    Karn, Ashish
    Dwivedi, Gaurav
    Kumar, Ashwani
    Mishra, Sachin
    Sharma, Naveen Kumar
    Bajaj, Mohit
    Zawbaa, Hossam M.
    Kamel, Salah
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [29] Thermal performance assessment of recyclic double-pass flat and V-corrugated plate solar air heaters
    Dhiman P.
    Singh S.
    International Journal of Sustainable Energy, 2017, 36 (01) : 78 - 100
  • [30] Energy and exergy assessment of new designed solar air heater of V-shaped transverse finned absorber at single- and double-pass flow conditions
    Abo-Elfadl, Saleh
    El-Dosoky, Mohamed F.
    Hassan, Hamdy
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (48) : 69074 - 69092