Performance evaluation of both-end open evacuated tube solar air heater: An experimental investigation

被引:0
作者
Chaudhari, Kuldeep [1 ]
Choudhary, Jai Prakash [1 ]
Mistry, Kirtan [1 ]
Tiwari, Abhishek [1 ]
Kumar, Amit [1 ]
机构
[1] Sardar Vallabhbhai Natl Inst Technol, Dept Mech Engn, Surat 395007, India
关键词
Energy efficiency; exergy efficiency; hot air; solar energy; sustainability index; WATER-HEATING SYSTEMS; THERMAL PERFORMANCE; FLAT-PLATE; COLLECTOR; ENERGY;
D O I
10.1080/15567036.2025.2463008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Hot air generation is essential for numerous applications, including drying, space heating, desiccant air conditioning, and seawater desalination. This study experimentally investigates a novel solar air heater that utilizes a both-end open evacuated tube collector. The research focuses on the effects of airflow rate, inclination angle, collector area, series, and parallel connection of solar air heater on system performance. The findings reveal that lower airflow rate, i.e. 100 kg/h yield higher hot air temperature (94.7 degrees C), whereas the highest efficiency (78.1%) occurs at higher airflow rate, i.e. 300 kg/h. Additionally, positioning the solar air heater at a 22 degrees angle enhances efficiency and hot air temperature by 47.5% and 27.3%, respectively, in comparison to 45 degrees angle. Expanding the collector area from 4.8 m2 to 14.4 m2 increases the temperature by 44%, though efficiency decreases by 47.7%. The series configuration outperforms the parallel configuration with 22.8% higher efficiency of the system. This study highlights the potential of the both-end open evacuated tube collector in enhancing the efficiency of solar air heater, offering valuable insights for the development of advanced solar thermal systems.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 29 条
[1]   Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate [J].
Ayompe, L. M. ;
Duffy, A. ;
Mc Keever, M. ;
Conlon, M. ;
McCormack, S. J. .
ENERGY, 2011, 36 (05) :3370-3378
[2]   Performance of the one-ended evacuated tubes as medium temperature solar air heaters at low flow rates [J].
Bakry, Ayman I. ;
EL-Samadony, Y. A. F. ;
El-Agouz, S. A. ;
Alshrombably, A. M. ;
Abdelfatah, K. S. ;
Said, M. A. .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2018, 30 :174-182
[3]  
Dabra V., 2013, INT J ENG SCI TECHNO, V5, P100, DOI DOI 10.4314/IJEST.V5I4.9
[4]   Investigating the single pass baffled solar air heater (SAH) with an organic PCM (OPCM) [J].
Dinesh, S. N. ;
Saminathan, Rajasekaran ;
Patil, Milind M. ;
Baviskar, Prasad Ramchandra ;
Hadidi, Haitham ;
Vignesh, S. ;
Kumar, P. Manoj .
MATERIALS TODAY-PROCEEDINGS, 2022, 62 :5245-5249
[5]   Enhanced performance assessment of an integrated evacuated tube and flat plate collector solar air heater with thermal storage material [J].
El-Fakharany, Magda K. ;
Abo-Samra, Aly-Eldeen A. ;
Abdelmaqsoud, A. M. ;
Marzouk, S. A. .
APPLIED THERMAL ENGINEERING, 2024, 243
[6]   Experimental study of solar air heater performance by evacuated tubes connected in series and loaded with thermal storage material [J].
Elbrashy, A. A. ;
Abou-Taleb, F. Sh. ;
El-Fakharany, Magda K. ;
Essa, Fadl A. .
JOURNAL OF ENERGY STORAGE, 2022, 54
[7]   A review on air heating applications with evacuated tubes: A focus on series and parallel tube configurations [J].
Elbrashy, Amr ;
Boutera, Yousra ;
Abdel-Aziz, Moataz M. ;
Dafea, Salah ;
Arici, Muesluem .
SOLAR ENERGY, 2023, 264
[8]   Thermohydraulic performance of solar air heaters with roughened absorber plates [J].
Gupta, D ;
Solanki, SC ;
Saini, JS .
SOLAR ENERGY, 1997, 61 (01) :33-42
[9]   A three-dimensional performance analysis of all-glass vacuum tubes with coaxial fluid conduit [J].
Han, Hyunjoo ;
Kim, Jeong Tai ;
Ahn, Hyun Tae ;
Lee, Sang Jin .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2008, 35 (05) :589-596
[10]   The evacuated tube solar collector assisted heat pump for heating greenhouses [J].
Hassanien, Reda Hassanien Emam ;
Li, Ming ;
Tang, Yilian .
ENERGY AND BUILDINGS, 2018, 169 :305-318