Cerebral Embolic Protection Devices in Transcatheter Aortic Valve Implantation: Meta-Analysis With Trial Sequential Analysis

被引:0
作者
Warraich, Nav [1 ,2 ]
Sa, Michel Pompeu [3 ]
Jacquemyn, Xander [4 ]
Kuno, Toshiki [5 ]
Serna-Gallegos, Derek [1 ,2 ]
Sultan, Ibrahim [1 ,2 ]
机构
[1] Univ Pittsburgh, Dept Cardiothorac Surg, Div Cardiac Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, UPMC Heart & Vasc Inst, Med Ctr, Pittsburgh, PA USA
[3] Harvard Med Sch, Massachusetts Gen Hosp, Div Cardiac Surg, Boston, MA USA
[4] Katholieke Univ Leuven, Leuven, Belgium
[5] Harvard Med Sch, Massachusetts Gen Hosp, Div Cardiol, Boston, MA USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2025年 / 14卷 / 07期
关键词
cerebral embolic protection devices; meta-analysis; TAVI; trial sequential analysis; RANDOMIZED EVALUATION; REPLACEMENT; LESIONS;
D O I
10.1161/JAHA.124.038869
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background We aimed to reevaluate randomized controlled trial data on outcomes of cerebral embolic protection device use during transcatheter aortic valve implantation. A conventional meta-analysis followed by trial sequential analysis was conducted to evaluate the strength of the current evidence.Methods and Results Databases were searched for randomized controlled trials. Primary outcomes included all stroke, disabling stroke, and all-cause mortality. Conventional study-level meta-analysis was performed using random-effects modeling. Trial sequential analysis was conducted to generate adjusted significance boundaries, futility boundaries, and the required information size considering a type I error of 5% and a power of 90%. Seven trials were included with a total of 4031 patients, of whom 2171 were treated with a device and 1860 were not. Conventional meta-analysis showed no significant difference in all stroke (relative risk [RR], 0.85 [95% CI, 0.61-1.18]; P=0.339) and disabling stroke (RR, 0.59 [95% CI, 0.30-1.13]; P=0.113) with device use. The trial sequential analysis determined an absence of evidence for all stroke (required information size of 71 650 [5.6%]) and disabling stroke (required information size of 337 256 [1.2%]). Conventional meta-analysis determined no significant difference in all-cause mortality (RR, 1.03 [95% CI, 0.49-2.17]; P=0.928) with device use. The trial sequential analysis determined that the futility boundary was reached (required information size of 5772 [69.3%]).Conclusions There are insufficient randomized controlled trial data on cerebral embolic protection device use to provide conclusive meta-analytic findings for stroke outcomes.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Transcaval access for transcatheter aortic valve implantation: A meta-analysis and systematic review
    Abraham, Bishoy
    Sous, Mina
    Kaldas, Sara
    Nakhla, Michael
    Sweeney, John
    Lee, Kwan
    Garcia, Santiago
    Saad, Marwan
    Goel, Sachin S.
    Fortuin, F. David
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2025, 419
  • [42] Meta-Analysis and Meta-Regression o f Transcatheter Aortic Valve Implantation for Pure Native Aortic Regurgitation
    Takagi, Hisato
    Hari, Yosuke
    Kawai, Norikazu
    Ando, Tomo
    HEART LUNG AND CIRCULATION, 2020, 29 (05) : 729 - 741
  • [43] Remote ischaemic preconditioning for transcatheter aortic valve replacement: a protocol for a systematic review with meta-analysis and trial sequential analysis
    Zhang, Weiyi
    Du, Li
    Chen, Guo
    Du, Bin
    Zhang, Lu
    Zheng, Jianqiao
    BMJ OPEN, 2024, 14 (04):
  • [44] Influence of Gender on Transcatheter Aortic Valve Implantation: A Systematic Review and Meta-Analysis
    Lang, Zekun
    Zhu, Youqi
    Jiang, Gaxue
    Ji, Pengfei
    Zhang, Xiaoqi
    Zhang, Yurong
    Sun, Xince
    Bai, Ming
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (04)
  • [45] Meta-analysis of the Impact of Avoiding Balloon Predilation in Transcatheter Aortic Valve Implantation
    Banerjee, Kinjal
    Kandregula, Krishna
    Sankaramangalam, Kesavan
    Anumandla, Anil
    Kumar, Arnav
    Parikh, Parth
    Kerrigan, Jimmy
    Khubber, Shameer
    Krishnaswamy, Amar
    Mick, Stephanie
    White, Jonathon
    Svensson, Lars
    Kapadia, Samir
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (03) : 477 - 482
  • [46] "Tailor-made" Total Cerebral Protection during Transcatheter Aortic Valve Implantation
    Suzuki, Keita
    Koyanagi, Masaomi
    Shirai, Shinichi
    Chihara, Hideo
    Ogura, Takenori
    Kamata, Takahiro
    Kitamura, Taisuke
    Ando, Kenji
    Hatano, Taketo
    NEUROLOGIA MEDICO-CHIRURGICA, 2021, 61 (12) : 741 - 749
  • [47] Meta-Analysis of Bioprosthetic Valve Thrombosis After Transcatheter Aortic Valve Implantation
    Rheude, Tobias
    Pellegrini, Costanza
    Stortecky, Stefan
    Marwan, Mohamed
    Xhepa, Erion
    Ammon, Fabian
    Pilgrim, Thomas
    Mayr, N. Patrick
    Husser, Oliver
    Achenbach, Stephan
    Windecker, Stephan
    Cassese, Salvatore
    Joner, Michael
    AMERICAN JOURNAL OF CARDIOLOGY, 2021, 138 : 92 - 99
  • [48] Meta-Analysis of Usefulness of Anticoagulation After Transcatheter Aortic Valve Implantation
    Banerjee, Kinjal
    Poddar, Kanhaiya
    Mick, Stephanie
    White, Jonathon
    Krishnaswamy, Amar
    Johnston, Douglas
    Rodriguez, Leonardo
    Tuzcu, Murat
    Kapadia, Samir
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 120 (09) : 1612 - 1617
  • [49] Meta-Analysis of Perioperative Stroke and Mortality in Transcatheter Aortic Valve Implantation
    Muralidharan, Aditya
    Thiagarajan, Karthy
    Van Ham, Raymond
    Gleason, Thomas G.
    Mulukutla, Suresh
    Schindler, John T.
    Jeevanantham, Vinodh
    Thirumala, Parthasarathy D.
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 118 (07) : 1031 - 1045
  • [50] Effect of Gender After Transcatheter Aortic Valve Implantation: A Meta-Analysis
    Conrotto, Federico
    D'Ascenzo, Fabrizio
    Presbitero, Patrizia
    Humphries, Karin H.
    Webb, John G.
    O'Connor, Stephen A.
    Morice, Marie-Claude
    Lefevre, Thierry
    Grasso, Costanza
    Sbarra, Pierluigi
    Taha, Salma
    Omede, Pierluigi
    Marra, Walter Grosso
    Salizzoni, Stefano
    Moretti, Claudio
    D'Amico, Maurizio
    Biondi-Zoccai, Giuseppe
    Gaita, Fiorenzo
    Marra, Sebastiano
    ANNALS OF THORACIC SURGERY, 2015, 99 (03) : 809 - 816