Cerebral Embolic Protection Devices in Transcatheter Aortic Valve Implantation: Meta-Analysis With Trial Sequential Analysis

被引:0
作者
Warraich, Nav [1 ,2 ]
Sa, Michel Pompeu [3 ]
Jacquemyn, Xander [4 ]
Kuno, Toshiki [5 ]
Serna-Gallegos, Derek [1 ,2 ]
Sultan, Ibrahim [1 ,2 ]
机构
[1] Univ Pittsburgh, Dept Cardiothorac Surg, Div Cardiac Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, UPMC Heart & Vasc Inst, Med Ctr, Pittsburgh, PA USA
[3] Harvard Med Sch, Massachusetts Gen Hosp, Div Cardiac Surg, Boston, MA USA
[4] Katholieke Univ Leuven, Leuven, Belgium
[5] Harvard Med Sch, Massachusetts Gen Hosp, Div Cardiol, Boston, MA USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2025年 / 14卷 / 07期
关键词
cerebral embolic protection devices; meta-analysis; TAVI; trial sequential analysis; RANDOMIZED EVALUATION; REPLACEMENT; LESIONS;
D O I
10.1161/JAHA.124.038869
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background We aimed to reevaluate randomized controlled trial data on outcomes of cerebral embolic protection device use during transcatheter aortic valve implantation. A conventional meta-analysis followed by trial sequential analysis was conducted to evaluate the strength of the current evidence.Methods and Results Databases were searched for randomized controlled trials. Primary outcomes included all stroke, disabling stroke, and all-cause mortality. Conventional study-level meta-analysis was performed using random-effects modeling. Trial sequential analysis was conducted to generate adjusted significance boundaries, futility boundaries, and the required information size considering a type I error of 5% and a power of 90%. Seven trials were included with a total of 4031 patients, of whom 2171 were treated with a device and 1860 were not. Conventional meta-analysis showed no significant difference in all stroke (relative risk [RR], 0.85 [95% CI, 0.61-1.18]; P=0.339) and disabling stroke (RR, 0.59 [95% CI, 0.30-1.13]; P=0.113) with device use. The trial sequential analysis determined an absence of evidence for all stroke (required information size of 71 650 [5.6%]) and disabling stroke (required information size of 337 256 [1.2%]). Conventional meta-analysis determined no significant difference in all-cause mortality (RR, 1.03 [95% CI, 0.49-2.17]; P=0.928) with device use. The trial sequential analysis determined that the futility boundary was reached (required information size of 5772 [69.3%]).Conclusions There are insufficient randomized controlled trial data on cerebral embolic protection device use to provide conclusive meta-analytic findings for stroke outcomes.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The Role of Cerebral Embolic Protection Devices During Transcatheter Aortic Valve Replacement
    Demir, Ozan M.
    Iannopollo, Gianmarco
    Mangieri, Antonio
    Ancona, Marco B.
    Regazzoli, Damiano
    Mitomo, Satoru
    Colombo, Antonio
    Weisz, Giora
    Latib, Azeem
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2018, 5
  • [22] Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement
    Yashima, Fumiaki
    Briasoulis, Alexandros
    Kuno, Toshiki
    Noguchi, Masahiko
    Ahmad, Hasan
    Zaid, Syed
    Goldberg, Joshua B.
    Malik, Aaqib H.
    Tang, Gilbert H. L.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 36 : 9 - 13
  • [23] Transcatheter Aortic Valve Implantation With or Without Predilation: A Meta-Analysis
    Conrotto, Federico
    D'Ascenzo, Fabrizio
    Franchin, Luca
    Bruno, Francesco
    Mamas, Mamas A.
    Toutouzas, Konstantinos
    Cuisset, Thomas
    Leclercq, Florence
    Dumonteil, Nicolas
    Latib, Azeem
    Nombela-Franco, Luis
    Schaefer, Andreas
    Anderson, R. David
    Marruncheddu, Laura
    Gallone, Guglielmo
    De Filippo, Ovidio
    La Torre, Michele
    Rinaldi, Mauro
    Omede, Pierluigi
    Salizzoni, Stefano
    De Ferrari, Gaetano Maria
    JOURNAL OF INVASIVE CARDIOLOGY, 2022, 34 (02) : E104 - +
  • [24] An Updated Meta-Analysis on Cerebral Embolic Protection in Patients Undergoing Transcatheter Aortic Valve Intervention Stratified by Baseline Surgical Risk and Device Type
    Khan, Safi U.
    Zahid, Salman
    Alkhouli, Mohamad A.
    Akbar, Usman Ali
    Zaid, Syed
    Arshad, Hassaan B.
    Little, Stephen H.
    Reardon, Michael J.
    Kleiman, Neal S.
    Goel, Sachin S.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2023, 7 (04):
  • [25] Image-guidance for transcatheter aortic valve implantation (TAVI) and cerebral embolic protection
    Vernikouskaya, I.
    Rottbauer, W.
    Gonska, B.
    Rodewald, C.
    Seeger, J.
    Rasche, V.
    Woehrle, J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 249 : 90 - 95
  • [26] Site Variability in Cerebral Embolic Protection for Transcatheter Aortic Valve Implantation and Association With Outcomes
    Ubaid, Aamer
    Kennedy, Kevin F.
    Chhatriwalla, Adnan K.
    Saxon, John T.
    Hart, Anthony
    Allen, Keith B.
    Aberle, Corinne
    Shatla, Islam
    Abumoawad, Abdelrhman
    Gunta, Satya Preetham
    Skolnick, David
    Huded, Chetan P.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2023, 7 (06):
  • [27] Cerebral protection devices during transcatheter aortic valve implantation
    Vlastra, Wieneke
    Vendrik, Jeroen
    Koch, Karel T.
    Baan, Jan
    Piek, Jan J.
    Delewi, Ronak
    TRENDS IN CARDIOVASCULAR MEDICINE, 2018, 28 (06) : 412 - 418
  • [28] Clinical impact of cerebral protection during transcatheter aortic valve implantation
    Boccuto, Fabiola
    Carabetta, Nicole
    Cacia, Michele Antonio
    Kanagala, Sai Gautham
    Panuccio, Giuseppe
    Torella, Daniele
    De Rosa, Salvatore
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2024, 54 (05)
  • [29] Transcatheter versus surgical aortic valve replacement for severe aortic valve stenosis: Meta-analysis with trial sequential analysis
    Jacquemyn, Xander
    Sa, Michel Pompeu
    Rega, Filip
    Verbrugghe, Peter
    Meuris, Bart
    Serna-Gallegos, Derek
    Brown, James A.
    Clavel, Marie-Annick
    Pibarot, Philippe
    Sultan, Ibrahim
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2025, 169 (04)
  • [30] Cerebral embolic protection systems for transcatheter aortic valve replacement
    Gasior, Tomasz
    Mangner, Norman
    Bijoch, Julia
    Wojakowski, Wojciech
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (06) : 891 - 898