Experimental study on seismic performance of assembled steel fully recycled concrete frame structure

被引:0
|
作者
Chen, Yuliang [1 ,2 ,3 ]
Wang, Shuangyi [1 ]
Liu, Jie [1 ]
Jiang, Rui [1 ]
Ye, Peihuan [1 ,2 ]
机构
[1] School of Civil Engineering and Architecture, Guangxi University of Science and Technology, Liuzhou,545006, China
[2] Guangxi Engineering Research Center for Safety Prevention and Control of Assembly Structure, Guangxi University of Science and Technology, Liuzhou,545006, China
[3] Key Laboratory of Disaster Prevention & Mitigation and Prestress Technology, Guangxi Colleges and Universities, Guangxi University of Science and Technology, Liuzhou,545006, China
来源
关键词
Arches - Bearings (structural) - Building moving - Columns (structural) - Concrete beams and girders - Concrete buildings - Cyclic loads - Electric towers - Fracture mechanics - Religious buildings - Seismic response - Shotcreting - Solar buildings - Water towers;
D O I
10.13465/j.cnki.jvs.2025.08.023
中图分类号
学科分类号
摘要
In order to study the seismic performance of the assembled steel fully recycled concrete frame-recycled concrete infilled wall structure, a cast-in-place steel reinforced concrete frame (control group) and two assembled steel reinforced recycled concrete frames with a scale ratio of 1: 2. 5 were designed. The mechanical properties such as hysteresis curve, skeleton curve, stiffness degradation, energy dissipation capacity, strength degradation and inter-story displacement angle of assembled steel reinforced fully recycled concrete were investigated by low cyclic loading test. The results show that the failure modes of the assembled steel fully recycled concrete frame and the cast-in-place ordinary concrete frame are similar, both of which are manifested as the failure of the plastic hinge zone at the beam end and the column bottom. The stiffness degradation of prefabricated steel reinforced recycled concrete frame is more obvious than that of cast-in-place ordinary concrete frame, and the maximum reduction is about 62. 54%. The energy dissipation capacity of the prefabricated steel reinforced recycled concrete frame with infill wall is the best, which is about 22. 22% higher than that of the cast-in-place steel reinforced concrete frame. The strength degradation coefficient of cast-in-place ordinary steel reinforced concrete frame and assembled steel reinforced recycled concrete frame is between 0. 89 and 0.91, and the strength degradation coefficient of assembled steel reinforced recycled concrete frame with infilled wall is between 0. 77 and 0. 82. The displacement ductility coefficient of the assembled steel reinforced recycled concrete frame is about 2. 14-4. 63, which is about 118. 40 % higher than that of the cast-in-place ordinary concrete structure. The ultimate inter-story displacement angle of cast-in-place steel ordinary concrete frame and assembled steel recycled concrete frame is between 1/39 and 1/28. The strain test results show that the bearing capacity of the structure is mainly controlled by the normal stress on the section. The plastic hinge begins to form at the beam end, and finally forms at the bottom of the column. The failure belongs to the beam hinge mechanism, which meets the seismic requirements of strong column and weak beam. © 2025 Chinese Vibration Engineering Society. All rights reserved.
引用
收藏
页码:209 / 219
相关论文
共 50 条
  • [41] EXPERIMENTAL STUDY ON SEISMIC PERFORMANCE OF REINFORCED CONCRETE SPLIT-FOUNDATION FRAME STRUCTURES WITH STEEL BRACES
    Liu, Li-Ping
    Li, Rui-Feng
    Yin, Yao-Ri
    Li, Ying-Min
    Deng, Fei
    Gongcheng Lixue/Engineering Mechanics, 2024, 41 (01): : 182 - 192
  • [42] Study on seismic behavior of steel frame with external hanging concrete walls containing recycled aggregates
    Sun, Lijian
    Guo, Hongchao
    Liu, Yunhe
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 157 : 790 - 808
  • [43] Seismic performance study on steel frame structure with integral panels
    Hou, Hetao
    Wu, Minglei
    Liu, Miao
    Ma, Qin
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 2373 - +
  • [44] Seismic performance of a steel frame assembled with a CFST-bordered composite wall structure
    Cao, Wan-Lin
    Wang, Ru-Wei
    Yin, Fei
    Dong, Hong-Ying
    ENGINEERING STRUCTURES, 2020, 219
  • [45] Experimental study and design recommendations on seismic behavior of spatial steel frame concrete frame structures
    Tang, Xingrong
    He, Baolin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (03): : 45 - 52
  • [46] Numerical analysis and experimental study of seismic performance of assembled concrete structures
    Duan, Liusheng
    Wu, Nan
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2024, 24 (4-5) : 3047 - 3061
  • [47] Experimental study of seismic performance of assembled concrete frames with UHPC connections
    Chen, Gang
    Nie, Xinxin
    Zheng, Qizhen
    Chen, Weigang
    Jiang, Haiyang
    STRUCTURES, 2024, 63
  • [48] Experimental study on seismic performance of precast concrete frame with grouting defects
    Li W.
    Pan Y.
    Wang S.
    Yang C.
    Xu F.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (07): : 123 - 130
  • [49] Experimental study on seismic behavior of wrapped steel concrete frame exterior joints
    Wu, Tao
    Bai, Guo-Liang
    Liu, Bo-Quan
    Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture and Technology, 2002, 34 (04):
  • [50] Experimental study on seismic performance of steel frame-K shaped brace structure system
    Lou Y.
    Wen L.
    Li W.
    Nie X.
    Wang A.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (11): : 32 - 40