Experimental study on seismic performance of assembled steel fully recycled concrete frame structure

被引:0
|
作者
Chen, Yuliang [1 ,2 ,3 ]
Wang, Shuangyi [1 ]
Liu, Jie [1 ]
Jiang, Rui [1 ]
Ye, Peihuan [1 ,2 ]
机构
[1] School of Civil Engineering and Architecture, Guangxi University of Science and Technology, Liuzhou,545006, China
[2] Guangxi Engineering Research Center for Safety Prevention and Control of Assembly Structure, Guangxi University of Science and Technology, Liuzhou,545006, China
[3] Key Laboratory of Disaster Prevention & Mitigation and Prestress Technology, Guangxi Colleges and Universities, Guangxi University of Science and Technology, Liuzhou,545006, China
来源
关键词
Arches - Bearings (structural) - Building moving - Columns (structural) - Concrete beams and girders - Concrete buildings - Cyclic loads - Electric towers - Fracture mechanics - Religious buildings - Seismic response - Shotcreting - Solar buildings - Water towers;
D O I
10.13465/j.cnki.jvs.2025.08.023
中图分类号
学科分类号
摘要
In order to study the seismic performance of the assembled steel fully recycled concrete frame-recycled concrete infilled wall structure, a cast-in-place steel reinforced concrete frame (control group) and two assembled steel reinforced recycled concrete frames with a scale ratio of 1: 2. 5 were designed. The mechanical properties such as hysteresis curve, skeleton curve, stiffness degradation, energy dissipation capacity, strength degradation and inter-story displacement angle of assembled steel reinforced fully recycled concrete were investigated by low cyclic loading test. The results show that the failure modes of the assembled steel fully recycled concrete frame and the cast-in-place ordinary concrete frame are similar, both of which are manifested as the failure of the plastic hinge zone at the beam end and the column bottom. The stiffness degradation of prefabricated steel reinforced recycled concrete frame is more obvious than that of cast-in-place ordinary concrete frame, and the maximum reduction is about 62. 54%. The energy dissipation capacity of the prefabricated steel reinforced recycled concrete frame with infill wall is the best, which is about 22. 22% higher than that of the cast-in-place steel reinforced concrete frame. The strength degradation coefficient of cast-in-place ordinary steel reinforced concrete frame and assembled steel reinforced recycled concrete frame is between 0. 89 and 0.91, and the strength degradation coefficient of assembled steel reinforced recycled concrete frame with infilled wall is between 0. 77 and 0. 82. The displacement ductility coefficient of the assembled steel reinforced recycled concrete frame is about 2. 14-4. 63, which is about 118. 40 % higher than that of the cast-in-place ordinary concrete structure. The ultimate inter-story displacement angle of cast-in-place steel ordinary concrete frame and assembled steel recycled concrete frame is between 1/39 and 1/28. The strain test results show that the bearing capacity of the structure is mainly controlled by the normal stress on the section. The plastic hinge begins to form at the beam end, and finally forms at the bottom of the column. The failure belongs to the beam hinge mechanism, which meets the seismic requirements of strong column and weak beam. © 2025 Chinese Vibration Engineering Society. All rights reserved.
引用
收藏
页码:209 / 219
相关论文
共 50 条
  • [31] Seismic performance of concrete filled steel tubular frame with integral assembled infilled wall
    Zhou Z.
    Xu Z.
    Tian L.
    Wang T.
    Li Y.
    Feng A.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2021, 53 (04): : 89 - 95
  • [32] STUDY ON SEISMIC BEHAVIOR OF RECYCLED CONCRETE FRAME CONSTRUCTION
    Cui, Zhenglong
    Kitatsuji, Masahumi
    Tanaka, Reiji
    2ND INTERNATIONAL CONFERENCE ON WASTE ENGINEERING MANAGEMENT, ICWEM 2010, 2010, 73 : 455 - +
  • [34] Investigation on the Seismic Damage of Recycled Aggregate Concrete Frame Structure
    Wang, Changqing
    Xiao, Jianzhuang
    JOURNAL OF EARTHQUAKE ENGINEERING, 2021, 25 (05) : 791 - 815
  • [35] Seismic performance of reinforced semi-recycled concrete frame
    Lü, X. (lxlst@tongji.edu.cn), 1600, Central South University of Technology (45):
  • [36] Study on Seismic Performance of Recycled Steel Fibers Locally Reinforced Cruciform Concrete Frame Beam-Column Joint
    Li, Yan
    Zhao, Rong-Hua
    Li, Dong-Yi
    Qu, Chang
    ADVANCES IN CIVIL ENGINEERING, 2022, 2022
  • [37] STUDY ON THE SEISMIC PERFORMANCE OF RECYCLED AGGREGATE CONCRETE-FILLED LIGHTWEIGHT STEEL TUBE FRAME WITH DIFFERENT ASSEMBLY JOINTS
    Liu Wenchao
    Cao Wanlin
    Qiao Qiyun
    Ren Lele
    Wang Ruwei
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2018, 27 (03):
  • [38] Experimental and numerical study on seismic performance of steel reinforced concrete spatial frame with irregular section columns
    Liu, Zuqiang
    Wang, Xiaonan
    Zhou, Zhiming
    Xue, Jianyang
    Lai, Binglin
    Xu, Jinjun
    ENGINEERING STRUCTURES, 2021, 242
  • [39] Experimental study and analysis on seismic performance of special-shaped steel reinforced concrete column frame
    Hui, Cun
    Li, Yonggang
    Li, Ke
    Hai, Ran
    Myers, John J.
    Li, Chunqing
    STRUCTURES, 2022, 37 : 353 - 363
  • [40] Experimental study on seismic performance of steel-concrete transfer joint without embedding into lower frame
    Gao J.
    Nie X.
    Ding R.
    Fan J.
    Fan Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (02): : 119 - 128