Correction Method for Deviations in Phase Angle for PMUs at Both Ends of a Transmission Line With Unknown Parameters

被引:0
|
作者
Yang, Jinzhou [1 ]
Gu, Lei [2 ]
Zheng, Xiang [3 ]
Yu, Yiting [1 ]
Kong, He [1 ,4 ]
Xu, Feiyang [5 ]
Zhang, Min [6 ]
Xue, Ancheng [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewable, Beijing 102206, Peoples R China
[2] State Grid Jiangsu Corp China, Zhangjiagang Power Supply Branch, Suzhou 215600, Peoples R China
[3] State Grid Zhejiang Corp China, Quzhou Power Supply Co, Quzhou 324000, Peoples R China
[4] State Grid Corp China, Northwest Branch, Xian 710000, Peoples R China
[5] State Grid Corp China, North China Branch, Beijing 100053, Peoples R China
[6] NARI Technol Co Ltd, Res & Dev Ctr, Nanjing 210032, Peoples R China
关键词
Voltage measurement; Phasor measurement units; Phase measurement; Reactive power; Current measurement; Synchronization; Power measurement; Mathematical models; Transmission line measurements; Time measurement; Deviations in phase angle difference; phasor measurement unit (PMU) data; power factor angle; synchronization correction; transmission line (TL); ONLINE CALIBRATION; DATA RECOVERY; ERRORS; TRANSFORMERS; ACCURACY; QUALITY;
D O I
10.1109/TIM.2024.3500037
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The phasor measurement units (PMUs) are the eyes for the dynamic of the power system. However, the measured phase angle data from PMUs for a transmission line (TL) may coexist with different deviations, i.e., the deviations in voltage/current phase angle difference (DVPAD/DCPAD) between different ends of the TL, and the deviations in power factor angle (DPFA, i.e., the deviations in phase angle difference between voltage and current at the same end), which threaten the advanced application with PMUs. This article proposes a correction method for the phase angle data when the DVPAD/DCPAD and DPFA coexist for the TL with unknown line parameters. Specifically, first, the abnormal voltage phase angle differences and power factor angle anomalies are discussed, and the corresponding illustrative examples are presented. Second, the mathematical model for estimating phase angle deviations in a general case is presented. Third, a "two-step" method to correct the phase angle data of PMU for the TLs with unknown parameters is proposed, in which the DVPAD/DCPAD between two ends is estimated in advance, and then, the DPFA is estimated. Finally, simulation and examples with field data verify the feasibility and engineering applicability of the proposed method.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Calibration Method of Phase Angle Difference for PMU at Both Ends of Transmission Line with Its Unknown Parameters
    Xue A.
    Xu J.
    Xu F.
    You H.
    Chow J.H.
    Bi T.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (12): : 129 - 135
  • [2] Coherence Verification of Transmission Line Parameters with PMUs measurements at its ends
    Lafond, Claude
    Kamwa, Innocent
    Prevost, Jacques
    Nadeau, Mathieu
    2015 IEEE 28TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2015, : 519 - 524
  • [3] Correction of Time-varying PMU Phase Angle Deviation with Unknown Transmission Line Parameters
    Xue, Ancheng
    Kong, He
    Xu, Feiyang
    Zhao, Junbo
    Chang, Naichao
    Chow, Joe H.
    Hong, Haiyan
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2023, 9 (01): : 315 - 325
  • [4] Robust Identification Method for Transmission Line Parameters That Considers PMU Phase Angle Error
    Xue, Ancheng
    Xu, Feiyang
    Martin, Kenneth E.
    You, Hongyu
    Wang, Li
    Wei, Guoen
    Xu, Jingsong
    IEEE ACCESS, 2020, 8 : 86962 - 86971
  • [5] Tracking Transmission Line Parameters in Power Grids Observed by PMUs
    Ren, Pengxiang
    Abur, Ali
    Lev-Ari, Hanoth
    2019 IEEE MILAN POWERTECH, 2019,
  • [6] A Method of Measuring Three Phase Transmission Line Parameters for Relay Settings
    Kato, M.
    Hisakado, T.
    Takani, H.
    Umezaki, H.
    Sekiguchi, K.
    T& D ASIA: 2009 TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: ASIA AND PACIFIC, 2009, : 168 - +
  • [7] Localizing faults in power transmission line with applying signals of directional elements at both line ends
    Herlender, Justyna
    Izykowski, Jan
    PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (07): : 135 - 139
  • [8] Correction of Phasor Measurements Independent of Transmission Line Parameters
    Xue, Ancheng
    Xu, Feiyang
    Xu, Jingsong
    Chow, Joe H.
    You, Hongyu
    Bi, Tianshu
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (01) : 346 - 356
  • [9] Measurement of fault resistances in transmission lines by using recorded signals at both line ends
    Sorrentino, Elmer
    Ayala, Carlos
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 140 : 116 - 120
  • [10] DETERMINATION OF THE TRANSMISSION LINE RESISTANCE MATRIX WITH DEVIATIONS OF DESIGN PARAMETERS FROM NOMINAL
    Kozlovskyi, V. V.
    Khrashchevskyi, R., V
    Klobukov, V. V.
    RADIO ELECTRONICS COMPUTER SCIENCE CONTROL, 2022, (02) : 7 - 14