An active electronic, high-density epidural paddle array for chronic spinal cord neuromodulation

被引:0
作者
Parker, Samuel R. [1 ]
Calvert, Jonathan S. [1 ]
Darie, Radu [1 ]
Jang, Jaeson [2 ,3 ]
Govindarajan, Lakshmi Narasimhan [2 ,3 ,4 ]
Angelino, Keith [5 ]
Chitnis, Girish [5 ]
Iyassu, Yohannes [5 ]
Shaaya, Elias [6 ,7 ]
Fridley, Jared S. [6 ,7 ]
Serre, Thomas [2 ,3 ]
Borton, David A. [1 ,3 ,6 ,7 ,8 ]
McLaughlin, Bryan L. [5 ]
机构
[1] Brown Univ, Sch Engn, Providence, RI 02912 USA
[2] Brown Univ, Cognit & Psychol Sci, Providence, RI USA
[3] Brown Univ, Carney Inst Brain Sci, Providence, RI 02912 USA
[4] MIT, Integrat Computat Neurosci ICoN Ctr, Cambridge, MA USA
[5] Microleads Med, Somerville, MA USA
[6] Brown Univ, Warren Alpert Med Sch, Dept Neurosurg, United, RI 02912 USA
[7] Rhode Isl Hosp, United, RI 02912 USA
[8] Providence VA Med Ctr, Ctr Neurorestorat & Neurotechnol, Providence, RI 02908 USA
关键词
neuromodulation; epidural electrical stimulation; implanted device; hermetic electronics; spinal electrophysiology; high density array; SOMATOSENSORY-EVOKED-POTENTIALS; COMPOUND ACTION-POTENTIALS; OVINE MODEL; STIMULATION; PAIN; OPTIMIZATION;
D O I
10.1088/1741-2552/adba8b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Epidural electrical stimulation (EES) has shown promise as both a clinical therapy and research tool for studying nervous system function. However, available clinical EES paddles are limited to using a small number of contacts due to the burden of wires necessary to connect each contact to the therapeutic delivery device, limiting the treatment area or density of epidural electrode arrays. We aimed to eliminate this burden using advanced on-paddle electronics. Approach. We developed a smart EES paddle with a 60-electrode programmable array, addressable using an active electronic multiplexer embedded within the electrode paddle body. The electronics are sealed in novel, ultra-low profile hermetic packaging. We conducted extensive reliability testing on the novel array, including a battery of ISO 10993-1 biocompatibility tests and determination of the hermetic package leak rate. We then evaluated the EES device in vivo, placed on the epidural surface of the ovine lumbosacral spinal cord for 15 months. Main results. The active paddle array performed nominally when implanted in sheep for over 15 months and no device-related malfunctions were observed. The onboard multiplexer enabled bespoke electrode arrangements across, and within, experimental sessions. We identified stereotyped responses to stimulation in lower extremity musculature, and examined local field potential responses to EES using high-density recording bipoles. Finally, spatial electrode encoding enabled machine learning models to accurately perform EES parameter inference for unseen stimulation electrodes, reducing the need for extensive training data in future deep models. Significance. We report the development and chronic large animal in vivo evaluation of a high-density EES paddle array containing active electronics. Our results provide a foundation for more advanced computation and processing to be integrated directly into devices implanted at the neural interface, opening new avenues for the study of nervous system function and new therapies to treat neural injury and dysfunction.
引用
收藏
页数:22
相关论文
共 69 条
  • [41] Restoration of sensory feedback from the foot and reduction of phantom limb pain via closed-loop spinal cord stimulation
    Nanivadekar, Ameya C.
    Bose, Rohit
    Petersen, Bailey A.
    Okorokova, Elizaveta, V
    Sarma, Devapratim
    Madonna, Tyler J.
    Barra, Beatrice
    Farooqui, Juhi
    Dalrymple, Ashley N.
    Levy, Isaiah
    Helm, Eric R.
    Miele, Vincent J.
    Boninger, Michael L.
    Capogrosso, Marco
    Bensmaia, Sliman J.
    Weber, Douglas J.
    Fisher, Lee E.
    [J]. NATURE BIOMEDICAL ENGINEERING, 2024, 8 (08) : 992 - +
  • [42] First Report on Real-World Outcomes with Evoked Compound Action Potential (ECAP)-Controlled Closed-Loop Spinal Cord Stimulation for Treatment of Chronic Pain
    Nijhuis, Harold J. A.
    Hofste, Willem-Jan
    Krabbenbos, Imre P.
    Dietz, Birte E.
    Mugan, Dave
    Huygen, Frank
    [J]. PAIN AND THERAPY, 2023, 12 (05) : 1221 - 1233
  • [43] High-density cortical μECoG arrays concurrently track spreading depolarizations and long-term evolution of stroke in awake rats
    Palopoli-Trojani, Kay
    Trumpis, Michael
    Chiang, Chia-Han
    Wang, Charles
    Williams, Ashley J.
    Evans, Cody L.
    Turner, Dennis A.
    Viventi, Jonathan
    Hoffmann, Ulrike
    [J]. COMMUNICATIONS BIOLOGY, 2024, 7 (01)
  • [44] Parker J.L., 2018, Bioelectron. Med, V1, P117, DOI [10.2217/bem-2017-0006, DOI 10.2217/BEM-2017-0006]
  • [45] Evoked Compound Action Potentials Reveal Spinal Cord Dorsal Column Neuroanatomy
    Parker, John L.
    Obradovic, Milan
    Hesam Shariati, Nastaran
    Gorman, Robert B.
    Karantonis, Dean M.
    Single, Peter S.
    Laird-Wah, James
    Bickerstaff, Mark
    Cousins, Michael J.
    [J]. NEUROMODULATION, 2020, 23 (01): : 82 - 95
  • [46] Electrically Evoked Compound Action Potentials Recorded From the Sheep Spinal Cord
    Parker, John L.
    Karantonis, Dean M.
    Single, Peter S.
    Obradovic, Milan
    Laird, James
    Gorman, Robert B.
    Ladd, Leigh A.
    Cousins, Michael J.
    [J]. NEUROMODULATION, 2013, 16 (04): : 295 - 303
  • [47] Pedregosa F, 2011, J MACH LEARN RES, V12, P2825
  • [48] High-Density, Actively Multiplexed μECoG Array on Reinforced Silicone Substrate
    Rachinskiy, Iakov
    Wong, Liane
    Chiang, Chia-Han
    Wang, Charles
    Trumpis, Michael
    Ogren, John I.
    Hu, Zhe
    McLaughlin, Bryan
    Viventi, Jonathan
    [J]. FRONTIERS IN NANOTECHNOLOGY, 2022, 4
  • [49] Ovine model of neuropathic pain for assessing mechanisms of spinal cord stimulation therapy via dorsal horn recordings, von Frey filaments, and gait analysis
    Reddy, Chandan G.
    Miller, John W.
    Abode-Iyamah, Kingsley O.
    Safayi, Sina
    Wilson, Saul
    Dalm, Brian D.
    Fredericks, Douglas C.
    Gillies, George T.
    Howard, Matthew A., III
    Brennan, Timothy J.
    [J]. JOURNAL OF PAIN RESEARCH, 2018, 11 : 1147 - 1162
  • [50] SILHOUETTES - A GRAPHICAL AID TO THE INTERPRETATION AND VALIDATION OF CLUSTER-ANALYSIS
    ROUSSEEUW, PJ
    [J]. JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 1987, 20 : 53 - 65