Experimental and GEANT4 simulated FEPE of NaI(Tl) detector for linear sources

被引:0
作者
Mansoor, Shahid [1 ,2 ]
Malik, Azhar Hussain [1 ]
Satti, Khizar Hayat [2 ,3 ]
Ijaz, Misbah [4 ]
Siddique, Muhammad Tariq [3 ]
机构
[1] Pakistan Inst Engn & Appl Sci PIEAS, Dept Nucl Engn DNE, Islamabad, Pakistan
[2] Pakistan Inst Nucl Sci & Technol PINSTECH, Hlth Phys Div HPD, PO Nilore, Islamabad, Pakistan
[3] Pakistan Inst Engn & Appl Sci PIEAS, Dept Phys & Appl Math DPAM, Islamabad, Pakistan
[4] Quaid I Azam Univ, Dept Math, Islamabad, Pakistan
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2025年 / 11卷 / 02期
关键词
NaI(Tl) scintillation detector; Tc-99m line source; full energy peak efficiency (FEPE); Monte Carlo (MC) GEANT4 simulations; MONTE-CARLO-SIMULATION; CIRCULAR DETECTOR; NAI DETECTOR; EFFICIENCY; MCNP;
D O I
10.1088/2057-1976/adaec8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using Tc-99m solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.7 cm. The FEPE is measured for the fabricated linear source using 2 '' x2 '' NaI(Tl) cylindrical detector at various source-detector distances. The experimental setup is simulated in GEANT4 and the computed FEPE values are compared with experimental values. The absolute error of 5% is observed between computed and measured FEPE values. Utilizing the advantages of MC simulations, the impact of numerous source parameters such as source length, diameter, source-detector distance, glass tube thickness and lead shield effects on FEPE are investigated to optimize the fabrication process of linear sources. A case study for current investigation has been analyzed by considering absolute FEPE of the NaI(Tl) system for a syringe filled with radioactive solution. This study provides an insight for the fabrication of standard linear sources by analyzing different source parameters and hence, may serve as a guideline to prepare standard linear sources for the calibration of radiation detectors.
引用
收藏
页数:9
相关论文
共 21 条
  • [1] Monte-Carlo modeling of a NaI(Tl) scintillator
    Ashrafi, S.
    Anvarian, S.
    Sobhanian, S.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 269 (01) : 95 - 98
  • [2] Bevelacqua J J., 2009, Contemporary Health Physics: Problems and Solutions: Second Edition, V2, P1, DOI [10.1002/9783527626809, DOI 10.1002/9783527626809]
  • [3] Blizard E P., 1968, Engineering Compendium on Radiation Shielding, V1, P363, DOI [10.1007/978-3-662-25858-36, DOI 10.1007/978-3-662-25858-36]
  • [4] Chaicraborty AK, 2019, PRAMANA-J PHYS, V92, DOI 10.1007/s12043-019-1735-1
  • [5] Calibration with MCNP of NaI detector for the determination of natural radioactivity levels in the field
    Cinelli, Giorgia
    Tositti, Laura
    Mostacci, Domiziano
    Bare, Jonathan
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 155 : 31 - 37
  • [6] An analytical solution for the solid angle subtended by a circular detector for a symmetrically positioned linear source
    Galiano, E
    Pagnutti, C
    [J]. APPLIED RADIATION AND ISOTOPES, 2006, 64 (05) : 603 - 607
  • [7] Calibration of well-type NaI(Tl) detector using a point sources measured out the detector well at different axial distances
    Gouda, M. M.
    Badawi, M. S.
    El-Khatib, A. M.
    Mohamed, M. M.
    Thabet, A. A.
    Abbas, M. I.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [8] Monte Carlo simulation of GM probe and NaI detector efficiency for surface activity measurements
    Grujic, Selena
    Dordevic, Ivana
    Milosevic, Miodrag
    Kozmidis-Luburic, Uranija
    [J]. RADIATION MEASUREMENTS, 2013, 58 : 45 - 51
  • [9] A hybrid method for calculating absolute peak efficiency of germanium detectors
    Jiang, SH
    Liang, JH
    Chou, JT
    Lin, UT
    Yeh, WW
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 413 (2-3) : 281 - 292
  • [10] Monte Carlo simulations of response functions for gas filled and scintillator detectors with MCNPX code
    Kovaltchouk, V.
    Machrafi, R.
    [J]. ANNALS OF NUCLEAR ENERGY, 2011, 38 (04) : 788 - 793