Accuracy of dental implants positioning in computer-assisted surgeries: In vitro study

被引:0
|
作者
Alpaca Zevallos, Erick Andres [1 ]
Ferreira Lima, Luciano Henrique [1 ]
Cortellazzi Mendes, Karine Laura [2 ]
Sverzut, Alexander Tadeu [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, UNICAMP, Piracicaba, SP, Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Hlth Sci & Childrens Dent, UNICAMP, Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental implants; Oral surgery; Data accuracy; Surgery; computer-assisted; GUIDED SURGERY; TEMPLATE; PLACEMENT; DENTISTRY; TOMOGRAPHY;
D O I
10.1016/j.jormas.2024.101828
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using computed tomography. Study design: This prospective in-vitro study used 30 polyurethane pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the dental implants as a control group, considered as the gold standard for postoperative comparison. Results: The difference between these methods is close to zero and not statistically significant (p > 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396. Conclusion: The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method. (c) 2024 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty
    Ming Han Lincoln Liow
    Graham Seow-Hng Goh
    Hee-Nee Pang
    Darren Keng Jin Tay
    Ngai Nung Lo
    Seng Jin Yeo
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1173 - 1180
  • [32] Prospective Clinical Study on the Accuracy of Static Computer-Assisted Implant Surgery in Patients With Distal Free-End Implants. Conventional Versus CAD-CAM Surgical Guides
    Berta, Garcia-Mira
    Luigi, Canullo
    Miguel, Penarrocha-Diago
    Carlos, Balaguer-Marti Jose
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (03) : 314 - 324
  • [33] Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty
    Liow, Ming Han Lincoln
    Goh, Graham Seow-Hng
    Pang, Hee-Nee
    Tay, Darren Keng Jin
    Lo, Ngai Nung
    Yeo, Seng Jin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (08) : 1173 - 1180
  • [34] In vitro and in vivo accuracy of autonomous robotic vs. fully guided static computer-assisted implant surgery
    He, Jin
    Zhang, Qinmeng
    Wang, Xueting
    Fu, Mengdie
    Zhang, Hui
    Song, Luyao
    Pu, Rui
    Jiang, Zhiwei
    Yang, Guoli
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 385 - 401
  • [35] Accuracy of Acetabular Component Positioning Using Computer-assisted Navigation in Direct Anterior Total Hip Arthroplasty
    Bradley, Michael P.
    Benson, Jessica R.
    Muir, Jeffrey M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [36] Digital Evaluation of the Accuracy of Computer-Guided Dental Implant Placement: An In Vitro Study
    Kim, Seong-Min
    Son, Keunbada
    Kim, Duk-Yeon
    Lee, Kyu-Bok
    APPLIED SCIENCES-BASEL, 2019, 9 (16):
  • [37] Internal Bone Temperature Change During Guided Surgery Preparations for Dental Implants: An In Vitro Study
    Migliorati, Marco
    Amorfini, Leonardo
    Signori, Alessio
    Barberis, Fabrizio
    Silvestrini Biavati, Armando
    Benedicenti, Stefano
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : 1464 - 1469
  • [38] Evaluation of the Accuracy, Surgical Time, and Learning Curve of Freehand, Static, and Dynamic Computer-Assisted Implant Surgery in an In Vitro Study
    Werny, Joscha Gabriel
    Fan, Shengchi
    Diaz, Leonardo
    Al-Nawas, Bilal
    Sagheb, Keyvan
    Gielisch, Matthias
    Schiegnitz, Eik
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [39] Positional accuracy during the sequence of static computer-assisted implant surgery in three alveolar ridge morphologies: An in vitro study
    Raabe, Clemens
    Abou-Ayash, Samir
    Yilmaz, Burak
    Surbek, Fiona Jennifer
    Chappuis, Vivianne
    Couso-Queiruga, Emilio
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (01): : 78 - 85
  • [40] Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study
    Li, Ping
    Zhao, Chunhui
    Chen, Jiahao
    Xu, Shulan
    Yang, Shuo
    Li, An
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1279 - 1288