Prospective Comparison of Clinical Outcomes After Bilateral Implantation of Diffractive Trifocal Extended Depth-of-Focus and Diffractive Trifocal Hydrophobic Intraocular Lenses

被引:0
作者
Nagy, Zoltan Z. [1 ]
Dorman, Peter [1 ]
Szalczer, Szilard [1 ]
Kiss, Huba [1 ]
机构
[1] Semmelweis Univ, Dept Ophthalmol, Maria Utca 39, H-1085 Budapest, Hungary
关键词
PATIENT SATISFACTION; REFRACTIVE OUTCOMES; VISUAL OUTCOMES; PERFORMANCE; IOLS; ORTHOKERATOLOGY; QUALITY; DESIGN; LASIK;
D O I
10.3928/1081597X-20241113-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare clinical outcomes for patients implanted with either FineVision HP or FineVision Triumf intraocular lenses (IOL) (Beaver-Visitec International, Inc) following cataract surgery. METHODS: Twenty-six patients bilaterally implanted with the HP IOL and 27 patients with the Triumf IOL were followed up for 6 months in a prospective randomized study. Refraction, uncorrected and corrected distance visual acuity (CDVA), uncorrected and distance-corrected intermediate visual acuity (DCIVA), and uncorrected and distance-corrected near visual acuity (DCNVA) were evaluated. Defocus curves and contrast sensitivity were also measured. Patient-reported outcomes were assessed using the National Eye Institute Visual Function Questionnaire 25, and adverse events were registered. RESULTS: Ninety-four percent of the eyes in both groups were within +/- 1.00 diopter (D) of spherical equivalent. All of the patients had 20/20 or better binocular CDVA in both groups and 96% and 100% had 20/25 or better binocular CDIVA in the Triumf and HP IOL groups, respectively, being reduced to 32% and 91.7% for DCNVA, respectively. Differences between groups were statistically significant from-2.00 to-4.50 D with better visual acuity outcomes for the HP IOL group (P < .01). Better monocular photopic contrast sensitivity was found for the Triumf IOL group at 12 and 18 cycles per degree (P < .01). There was a statistically significant increase of the overall composite score in both groups before and after surgery (P < .001). Spectacle independence was similar between groups for distance and intermediate vision but higher for the HP IOL for near vision (96% versus 75%). There were no adverse events related to the IOLs. CONCLUSIONS: Both IOLs showed good and comparable distance and intermediate visual acuities but near vision was better for the HP IOL. This model provided higher spectacle independence for near vision.
引用
收藏
页码:e102 / e113
页数:17
相关论文
共 32 条
[1]   Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, Begona ;
Madrid-Costa, David ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) :1090-1096
[2]   Optical analysis, reading performance, and quality-of-life evaluation after implantation of a diffractive multifocal intraocular lens [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Pinero, David P. ;
Amparo, Francisco ;
Jimenez, Ramon ;
Rodriguez-Prats, Jose L. ;
Javaloy, Jaime ;
Pongo, Vanessa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) :27-37
[3]   Effect of LASIK and Contact Lens Corneal Refractive Therapy on Higher Order Aberrations and Contrast Sensitivity Function [J].
Anera, Rosario G. ;
Villa, Cesar ;
Jimenez, Jose R. ;
Gutierrez, Ramon .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (03) :277-284
[4]   Comparison of Bilateral Reading Performance Among Two Presbyopia-Correcting Intraocular Lenses [J].
Benyoussef, Anas-Alexis ;
Reboux, Noemi ;
Cochener, Beatrice .
JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (07) :428-+
[5]   Visual Outcomes and Optical Quality of Accommodative, Multifocal, Extended Depth-of-Focus, and Monofocal Intraocular Lenses in Presbyopia-Correcting Cataract Surgery A Systematic Review and Bayesian Network Meta-analysis [J].
Cho, Jeong-Yeon ;
Won, Yeo Kyoung ;
Park, Jongyeop ;
Nam, Jin Hyun ;
Hong, Ji-Yoon ;
Min, Serim ;
Kim, Nahyun ;
Chung, Tae-Young ;
Lee, Eui-Kyung ;
Kwon, Sun-Hong ;
Lim, Dong Hui .
JAMA OPHTHALMOLOGY, 2022, 140 (11) :1045-1053
[6]   Clinical prospective intra-individual comparison after mix-and-match implantation of a monofocal EDOF and a diffractive trifocal IOL [J].
Danzinger, Victor ;
Schartmueller, Daniel ;
Schwarzenbacher, Luca ;
Roggla, Veronika ;
Abela-Formanek, Claudette ;
Menapace, Rupert ;
Leydolt, Christina .
EYE, 2023, 38 (2) :321-327
[7]   Visual and Refractive Outcomes of a New Hydrophobic Trifocal Toric Intraocular Lens [J].
Daya, Sheraz ;
Lagana, Marcela Espinosa .
CLINICAL OPHTHALMOLOGY, 2024, 18 :997-1007
[8]   Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens [J].
Fernandez-Vega, Luis ;
Alfonso, Jose F. ;
Baamonde, Begona ;
Madrid-Costa, David ;
Montes-Mico, Robert ;
Lozano, Javier .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) :214-220
[9]   Impact of Lens Material on Objective Refraction in Eyes with Trifocal Diffractive Intraocular Lenses [J].
Garzon, Nuria ;
Poyales, Francisco ;
Garcia-Montero, Maria ;
Vega, Fidel ;
Millan, Maria Sagrario ;
Albarran-Diego, Cesar .
CURRENT EYE RESEARCH, 2022, 47 (01) :51-61
[10]   Design and qualification of a diffractive trifocal optical profile for intraocular lenses [J].
Gatinel, Damien ;
Pagnoulle, Christophe ;
Houbrechts, Yvette ;
Gobin, Laure .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) :2060-2067