Robust kinetics estimation from kinematics via direct collocation

被引:0
|
作者
Wang, Kuan [1 ]
Zhang, Linlin [1 ]
Liang, Leichao [1 ]
Shao, Jiang [2 ]
Chen, Xinpeng [2 ]
Wang, Huihao [3 ]
机构
[1] Shanghai Univ Med & Hlth Sci, Coll Rehabil Sci, Shanghai, Peoples R China
[2] Tongji Univ, YangZhi Rehabil Hosp, Shanghai Sunshine Rehabil Ctr, Sch Med, Shanghai, Peoples R China
[3] Shanghai Univ Tradit Chinese Med, Shuguang Hosp, Shuguang Hosp Affiliated, Shis Ctr Orthoped & Traumatol,Inst Traumatol, Shanghai, Peoples R China
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
基金
上海市自然科学基金; 中国国家自然科学基金;
关键词
kinetics; kinematics; ground reaction force; direct collocation; simulation; MUSCLE; BIOMECHANICS;
D O I
10.3389/fbioe.2024.1483225
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction Accurate joint moment analysis is essential in biomechanics, and the integration of direct collocation with markerless motion capture offers a promising approach for its estimation. However, markerless motion capture can introduce varying degrees of error in tracking trajectories. This study aims to evaluate the effectiveness of the direct collocation method in estimating kinetics when joint trajectory data are impacted by noise.Methods We focused on walking and squatting movements as our target activities. To assess the method's robustness, we created five groups with differing noise levels-noise-free, mild noise, noisy group1, noisy group2, and a Gaussian noise group-in the joint center trajectories. Our approach involved combining joint center tracking with biological terms within the direct collocation scheme to address noise-related challenges. We calculated kinematics, joint moments, and ground reaction forces for comparison across the different noise groups.Results For the walking task, the mean absolute errors (MAEs) for the knee flexion moments were 0.103, 0.113, 0.127, 0.129, and 0.116 Nm/kg across the respective noise levels. The corresponding MAEs of the ankle flexion moment were 0.130, 0.133, 0.145, 0.131, and 0.138 Nm/kg. The hip flexion moment had MAEs of 0.182, 0.204, 0.242, 0.246, and 0.249 Nm/kg in the respective groups. In squatting, the MAEs of ankle flexion moments were 0.207, 0.219, 0.217, 0.253, and 0.227 Nm/kg in the noise-free, mild noise, noisy group1, noisy group2, and the Gaussian noise group, respectively. The MAEs of the knee flexion moments were 0.177, 0.196, 0.198, 0.197, and 0.221 Nm/kg, whereas the mean MAEs of the hip flexion moments were 0.125, 0.135, 0.141, 0.161, and 0.178 Nm/kg in the respective groups.Conclusion The results highlight that the direct collocation method incorporating both tracking and biological terms in the cost function could robustly estimate joint moments during walking and squatting across various noise levels. Currently, this method is better suited to reflect general activity dynamics than subject-specific dynamics in clinical practice. Future research should focus on refining cost functions to achieve an optimal balance between robustness and accuracy.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Li extraction from model brine via electrocoagulation: Processing, kinetics, and mechanism
    Zhang, Ye
    Xu, Rui
    Sun, Wei
    Wang, Li
    Tang, Honghu
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 250 (250)
  • [32] A Direct Path from Geometrical Data to Electromagnetic Field Estimation using Isogeometric Analysis
    Khajah, T.
    Hou, G.
    2015 31st International Review of Progress in Applied Computational Electromagnetics (ACES) Vol 31, 2015,
  • [33] Robust heart rate estimation from mobile face videos using an auto-encoder
    Lomaliza, J. -P.
    Park, H.
    ELECTRONICS LETTERS, 2020, 56 (22) : 1169 - 1171
  • [34] Equilibrium and kinetics studies for adsorption of direct blue 71 from aqueous solution by wheat shells
    Bulut, Yasemin
    Gozubenli, Numan
    Aydin, Haluk
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 144 (1-2) : 300 - 306
  • [35] Bioremoval of Direct Red from aqueous solution by Pseudomonas putida and its adsorption isotherms and kinetics
    Deepa, K.
    Chandran, Preethy
    Khan, S. Sudheer
    ECOLOGICAL ENGINEERING, 2013, 58 : 207 - 213
  • [36] Pyrolysis characteristics and kinetics of residue from China Shenhua industrial direct coal liquefaction plant
    Xu, Long
    Tang, Mingchen
    Duan, Lin'e
    Liu, Baolin
    Ma, Xiaoxun
    Zhang, Yulong
    Argyle, Morris D.
    Fan, Maohong
    THERMOCHIMICA ACTA, 2014, 589 : 1 - 10
  • [37] Phase function estimation from a diffuse optical image via deep learning
    Liang, Yuxuan
    Niu, Chuang
    Wei, Chen
    Ren, Shenghan
    Cong, Wenxiang
    Wang, Ge
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (07)
  • [38] Equilibrium and kinetics studies for the adsorption of direct and acid dyes from aqueous solution by soy meal hull
    Arami, Mokhtar
    Limaee, Nargess Yousefi
    Mahmoodi, Niyaz Mohammad
    Tabrizi, Nooshin Salman
    JOURNAL OF HAZARDOUS MATERIALS, 2006, 135 (1-3) : 171 - 179
  • [39] Direct cleavage of sorbitol from oligosaccharides via a sequential hydrogenation-hydrolysis pathway
    Negahdar, Leila
    Hausoul, Peter J. C.
    Palkovits, Stefan
    Palkovits, Regina
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2015, 166 : 460 - 464
  • [40] Direct Estimation of Voxel-Wise Neurotransmitter Response Maps From Dynamic PET Data
    Angelis, Georgios I.
    Gillam, John E.
    Ryder, William J.
    Fulton, Roger R.
    Meikle, Steven R.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (06) : 1371 - 1383