Comparison of ex vivo lesion formation for two adjacent radiofrequency applications with very high-power short-duration in various inter-lesion times

被引:1
|
作者
Hanaki, Yuichi [1 ]
Komatsu, Yuki [1 ]
Iioka, Yuto [1 ]
Ishizu, Tomoko [1 ]
Nogami, Akihiko [1 ,2 ]
机构
[1] Univ Tsukuba, Inst Med, Dept Cardiol, Tsukuba, Japan
[2] Tokyo Heart Rhythm Hosp, Arrhythmia Res Inst, Tokyo, Japan
关键词
atrial fibrillation; catheter ablation; inter-lesion distance; inter-lesion time; very high-power short-duration; PULMONARY VEIN ISOLATION; ATRIAL-FIBRILLATION; ABLATION;
D O I
10.1002/joa3.13192
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives Very high-power and short-duration (vHPSD) ablation with QDOT MICRO (TM) facilitates speedy and safe ablation for pulmonary vein isolation. A brief time interval between ablating two neighboring sites with vHPSD may potentially influence the size and geometry of the lesions. This study evaluates lesion formation when delivering adjacent applications using vHPSD at various inter-lesion times (ILTs). Methods Radiofrequency applications were conducted by QDOT MICRO (TM) catheter with 90 W of strength and 4 s duration. Fresh swine heart tissue on the epicardium was ablated with 10 g of the contact force. Lesions were created using a single application (SA) and double applications (DA) of adjacent lesions with a 6 mm distance between them as measured on the 3D mapping system. The DA was performed with various ILTs, 60 s (DA-60 s), 10 s (DA-10 s), 5 s (DA-5 s), and 0 s (DA-0 s). Results Out of 90 lesions, 79 were analyzed. Eleven lesions were excluded for one steam pop event, seven out of the target distance, and three divided lesions of two applications. There were no significant differences in surface diameter, cross-sectional diameter, and maximal lesion depth in each application among the groups. The intermediate lesion depth was significantly more profound in groups with shorter and immediate ILT (DA-10, 5, and 0 s) compared to the group with a prolonged ILT between two applications (DA-60 s) (2.99, 3.03, 3.16 mm vs. 2.42 mm, respectively; p < .001). Conclusions Two adjacent radiofrequency applications with vHPSD in short ILT may result in deeper lesions in the middle of combined double lesions.
引用
收藏
页数:6
相关论文
共 43 条
  • [1] Editorial to "comparison of ex vivo lesion formation for two adjacent radiofrequency applications with very-high-power short-duration in various inter-lesion times"
    Fukuzawa, Koji
    Takami, Mitsuru
    Imamura, Kimitake
    JOURNAL OF ARRHYTHMIA, 2025, 41 (01)
  • [2] Characteristics of Very High-Power, Short-Duration Radiofrequency Applications
    Orban, Gabor
    Sallo, Zoltan
    Perge, Peter
    abraham, Pal
    Piros, Katalin
    Nagy, Klaudia Vivien
    Osztheimer, Istvan
    Merkely, Bela
    Geller, Laszlo
    Szegedi, Nandor
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [3] High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics
    Bourier, Felix
    Duchateau, Josselin
    Vlachos, Konstantinos
    Lam, Anna
    Martin, Claire A.
    Takigawa, Masateru
    Kitamura, Takeshi
    Frontera, Antonio
    Cheniti, Ghassen
    Pambrun, Thomas
    Klotz, Nicolas
    Denis, Arnaud
    Derval, Nicolas
    Cochet, Hubert
    Sacher, Frederic
    Hocini, Meleze
    Haissaguerre, Michel
    Jais, Pierre
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (11) : 1570 - 1575
  • [4] Impact of High-Power Short-Duration Radiofrequency Ablation on Long-Term Lesion Durability for Atrial Fibrillation Ablation
    Yavin, Hagai D.
    Leshem, Eran
    Shapira-Daniels, Ayelet
    Sroubek, Jakub
    Barkagan, Michael
    Haffajee, Charles, I
    Cooper, Joshua M.
    Anter, Elad
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (08) : 973 - 985
  • [5] Relative contribution of contact force to lesion depth using high-power short-duration radiofrequency applications
    Steiger, Nathaniel
    Mcclennen, Logan
    Bilenker, Justin
    Vander Elst, Lucas
    Matos, Carlos
    Gracia, Ely
    Nauffal, Victor
    Zei, Paul C.
    Romero, Jorge E.
    Sauer, William H.
    HEART RHYTHM, 2024, 21 (09) : 1738 - 1740
  • [6] Impact of contact force on the lesion characteristics of very high-power short-duration ablation using a QDOT-MICRO catheter
    Yamaguchi, Junji
    Takigawa, Masateru
    Goya, Masahiko
    Martin, Claire A.
    Negishi, Miho
    Yamamoto, Tasuku
    Ikenouchi, Takashi
    Goto, Kentaro
    Shigeta, Takatoshi
    Kawamura, Iwanari
    Nishimura, Takuro
    Takamiya, Tomomasa
    Tao, Susumu
    Miyazaki, Shinsuke
    Sasano, Tetsuo
    JOURNAL OF ARRHYTHMIA, 2024, 40 (02) : 247 - 255
  • [7] Comparison of In Vivo Tissue Temperature Profile and Lesion Geometry for Radiofrequency Ablation With High Power-Short Duration and Moderate Power-Moderate Duration: Effects of Thermal Latency and Contact Force on Lesion Formation
    Nakagawa, Hiroshi
    Ikeda, Atsushi
    Sharma, Tushar
    Govari, Assaf
    Ashton, John
    Maffre, Jennifer
    Lifshitz, Alexander
    Fuimaono, Kristine
    Yokoyama, Katsuaki
    Wittkampf, Fred H. M.
    Jackman, Warren M.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (07) : 605 - 617
  • [8] Comparison of Very High-Power Short-Duration, HighPower Short-Duration, and Low-Power Long-Duration Radiofrequency Ablation for Atrial Fibrillation: A Systematic Review and Network MetaAnalysis
    Junarta, Joey
    Rodriguez, Sebastian
    Ullah, Waqas
    Siddiqui, Muhammad
    Riley, Joshua M.
    Patel, Anjani
    Dikdan, Sean J.
    Fradin, James J.
    Rosen, Jake
    Frisch, Daniel J.
    CIRCULATION, 2023, 148
  • [9] Impact of High-Power and Very High-Power Short-Duration Radiofrequency Ablation on Procedure Characteristics and First-Pass Isolation During Pulmonary Vein Isolation
    Sallo, Zoltan
    Perge, Peter
    Balogi, Bernadett
    Orban, Gabor
    Piros, Katalin
    Herczeg, Szilvia
    Nagy, Klaudia Vivien
    Osztheimer, Istvan
    abraham, Pal
    Merkely, Bela
    Geller, Laszlo
    Szegedi, Nandor
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [10] In silico analysis of the relation between conventional and high-power short-duration RF ablation settings and resulting lesion metrics
    Bourier, Felix
    Vlachos, Konstantinos
    Frontera, Antonio
    Martin, Claire A.
    Lam, Anna
    Takigawa, Masateru
    Kitamura, Takeshi
    Cheniti, Ghassen
    Duchateau, Josselin
    Pambrun, Thomas
    Derval, Nicolas
    Denis, Arnaud
    Cochet, Hubert
    Hocini, Meleze
    Sacher, Frederic
    Haissaguerre, Michel
    Jais, Pierre
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) : 1332 - 1339